C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional 8-channel 4-20mA analog outputs. Operates on 10-30VDC or 110/220V 50/60Hz AC. Available certifications: CSA and UL. Includes Modbus RTU slave RS-485 port for sending data to PC, PLC or DCS.

Inquiry

The C1 Protector Controller is an ideal solution for monitoring up to 16 critical input variables.

Flexibility

Built around ‘plug and play’ input and output modules, the C1 Protector controller can accept signals from wireless monitors, analog sensors, digital sensors, discrete inputs or even direct connection to bridge-style combustible or VOC sensors. Built-in calibration mode, three programmable alarm levels per channel and four common relays (A1, A2, FAULT and HORN) are included in the base configuration. Up to sixteen 4-20mA analog outputs, 48 discrete relays and an Ethernet interface are available as options.

Status “At A Glance”

The high resolution graphic LCD displays data as trends, bargraphs and calibrated engineering units; a 24-hour trend graph for each channel is always available. Forty-eight high intensity LEDs show channel status in real-time. In addition to touch-sensitive buttons, a standard magnetic keypad allows non-intrusive operation in potentially hazardous locations.

Digitally Connected, Wireless Enabled

The C1 Protector controller includes both master and slave RS-485 serial MODBUS interfaces for maximum flexibility. The C1’s master port reads data from remote RS-485 serial or wireless sensors, while the slave port enables remote MODBUS masters to access the C1’s channel and configuration data in real time.

Built-in support for GDS Corp GASMAX wireless gas monitors makes it easy to install and manage a wireless system. Using GDS Corp’s ProtectorView software and MODBUS / TCP interface, a remote display of the controller’s real-time status and stored configuration is available across any Ethernet network.

Reliability

The C1 Protector is designed from the ground up for critical alarm monitoring and is CSA certified for use in Class I Division 2 hazardous areas. In addition to gas detection, the C1 Protector controller is widely used in flow measurement, tank level monitoring and other critical alarm applications. The C1 Protector is available in panel mount, single or dual rack mount, NEMA 4X fiberglass and stainless steel, and NEMA 7 explosion proof enclosures.

FEATURES

  • 8/16 channels of analog, digital, wireless or bridge-type input
  • Large LCD display shows values, bar-graph and 24 hr trend data
  • Built-in support for GASMAX wireless gas monitors
  • Individual alarm LEDS for each channel and alarm (total of 48)
  • Standard 5A SPDT common relays for HORN, A2, A1 & FAULT
  • Up to 48 discrete relays for easy interface to existing circuitry
  • Relay voting logic reduces need for external hardware
  • One or two optional 8-channel 4-20mA analog outputs
  • ACK button silences HORN without affecting alarm relays
  • Pushbutton zero and span calibration for directly connected sensors
  • Operates on 10-30VDC or 110/220V 50/60 Hz AC
  • MODBUS® master and slave ports for maximum flexibility
  • CSA C22.2 No. 1010.1 & 152 for combustibles & ISA S82.02; UL 1604 / C22.2 No 213 (Div 2 Groups A, B, C, D); EN55011 & EN61000 (CE Mark).
  • Manufactured in USA

C1 Protector SPECIFICATIONS
Power Input: 10-30VDC or 110/220 V 50/60Hz AC; 150W AC power
supply included; 12 Watts MAX for electronics
Display Backlit 240x128 pixel LCD shows trend, bargraph and
engineering units; 52 discrete LEDs show channel status
in real time
Wireless Input Up to 16 remote GASMAX wireless gas monitors.
Select option “M” or add external radio module.
Analog Input Optional 8 or 16 4-20mA source into 100 ohms; includes
excitation for easy connection to 2 or 3 wire transmitters
MODBUS I/O 1 MODBUS master RS-485 half or full duplex port
capable of reading remote GASMAX sensors, other
compatible slave devices or wireless
MODBUS slave RS-485 half or full duplex port capable
of being read by remote MODBUS master device
Relay Output Standard common output relays: A1, A2, FAIL &
HORN; SPDT rated 5A@ 30DC/240AC
Optional auxiliary relay board with secondary A1, A2
and HORN; SPDT rated 5A
Optional 8 channel discrete relay board (up to 6x)
Analog Output Optional 6 or 16 channel 4-20mA output *10 bit (D/A).
Max loop R is 800 ohms with nominal 24VDC supply.
Operating Temp -20°C to +50°C for standard sensors
-40°C to +65°C for extended temperature sensors (xT)
Digital Output Optional printer output or MODBUS / TCP interface.
Temp -25C to +65C
Mounting Panel mount for 19” rack; NEMA 4X wall-mount suitable
for Class 1 Div 2 Groups B, C, D; NEMA 7 wallmount
suitable for Class 1 Div 1 Groups B, C, D
Dimensions NEMA 4X fiberglass: Width 13” (330 mm); Height 16”
(406 mm); Depth 8.63” (220 mm); Panel Mount: 5.25” x
9.20” cutout
Approvals CSA C22.2 No. 1010.1 & 152 for combustibles & ISA
S82.02; UL 1604 / C22.2 No 213 (Div 2 Groups A, B,
C, D); EN55011 & EN61000 (CE Mark).
Warranty 2 years from date of purchase
Export Info
Harmonized Tariff Code (HTC)8531100045
> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
SM87HXBA_B024RNNNNNNNNNR
(824)

MEDC  SM87HXBAB024RNNNNNNNNNR

MEDC Xenon strobe beacon (5 Joule), Explosion proof, EExd(e), Weatherproof, IP66 and IP67, designed for use in harsh environmental conditions. -55C to +70C, stainless steel or marine grade alloy. ATEX Certified, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T65°C/T80°C/T95°C Db. CSA, Inmetro, CUTR, IECEx and CQST certifications also available.

Configure

$1,557.01 
> 16-CHANNEL :    2 Items found.
100-0009-01-A
(4724)

ESP SAFETY  100-0009-01-A

ESP Safety UPES 16-channel (4-20mA) gas and flame detector controller, or 128 Modbus digital RS-485 channels (16 ports 8 channels each) for ESP Devices. Includes Modbus RS-485 output port (both analog and digital versions), power supply and 3 alarm relays and audible alert. 3Ux19" modular size, FM & ABS Class I Division 1, Ex CE and IECEx Approved.

Configure

$1,732.50 
TPPLBDWA2NNNNNN-TPPLEDWA2NNNNNN
(5827)

HONEYWELL  TPPLBDWA2NNNNNN-TPPLEDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for 16 gas detection channels (includes expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8 x mA outputs. IP65. UL and CSA approvals (Class I Div 2).

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.