Honeywell Touchpoint Plus Wall-mounted Alarm Controller for 16 gas detection channels (includes expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8 x mA outputs. IP65. UL and CSA approvals (Class I Div 2).

TPPLBDWA2NNNNNN-TPPLEDWA2NNNNNN   
Please Email us your request for quote   

Power
Input Option
Relay Option
Base unit includes 3 common alarm relays
Output Option
Battery
Communication
TPPLE Expansion units can communicate through this card but the expansion units must be purchased at the time of the base unit being ordered.
Communication 2
TPPLE Expansion units can communicate through this card but the expansion units must be purchased at the time of the base unit being ordered.
Power
Input Option
Relay Option
Base unit includes 3 common alarm relays
Output Option
Battery
Custom Configuration
Customer must provide channel details, gas name, tag names, alarm levels and type (latching,non-latching), these fees do not include advanced configuration such as voting and sequencing.

   8 Weeks  ]
251 Variants of base SKU / 30 Shown

The interconnection between the base unit and the expansion is shielded pair for the communication interface between the 2 units. The AC power is pulled locally.

Touchpoint Plus brings a whole new control experience to your small system of gas detectors. Touchpoint Plus is an easily configurable, wall-mounted control system that supports up to 16 gas detection channels. Its modular approach enables you to take control and configure what you need for a wide range of applications.

The signature feature of the Touchpoint line is a user-friendly touchscreen interface, which the Touchpoint Plus takes to a new level. With this unique interface, it’s easier than ever to see the status of your system at a glance - maximizing the time you have to make the right decisions. The intuitive, multilingual interface simplifies operation and reduces training requirements. The full-color stoplight-style status indication provides clarity from a distance too.

Touchpoint Plus features a comprehensive set of outputs as standard, including common alarms and dedicated drives for remote audiovisual indicators. Its modularity enables you to customize your system to meet your specific application requirements. Selecting the right detector for use with your controller can deliver significant savings in startup costs and ongoing operations. Our global partner network and dedicated application specialists are able to help you make the right choices for your industry.

With everything at your fingertips, you can take ownership of your system and operate it with confidence, helping to ensure the safety of your people and the productivity of your site.

Delivering Reliable Control
  • Honeywell reliability from the most trusted experts in gas detection
  • Built-in battery backup for constant uptime
  • Robust, shockproof housing for a wide range of industrial environments
Flexible Capabilities
  • Compatible with the full range of Honeywell gas detectors
  • Powered audiovisual alarms simplify field installation
  • Configuration includes easy grouping and voting alarm logic without specialist knowledge
  • Next-generation compatibility
  • Optional Modbus output for integration with a higher level system
Providing Ease and Efficiency
  • Quick and easy installation, configuration, setup, and maintenance
  • Easy diagnostics, data, and reporting
  • Minimum training time
  • Large color touchscreen LCD
  • Multilingual functionality
  • Green-yellow-red status at a glance
Honeywell Analytics’ one system solution to meet your safety requirements

Touchpoint Plus provides a reliable safety solution for small-scale gas detection systems across a wide range of applications and industries. If you need to integrate your gas detection with a higher level management system, the Modbus output option makes this straightforward.

As the heart of your gas detection system, Touchpoint Plus is designed to work with Honeywell’s industry-leading gas detectors and drive actuators, and audible and visual alarms to provide a complete end-to-end solution that you can configure as your own.

Designed for Speed and Reliability

Made of high-impact polymer plastic, Touchpoint Plus is versatile and durable. It is dustproof and waterproof, and has been tested to withstand the toughest operating environments, both indoors and out. So you can count on the Touchpoint Plus to stand up to the challenges of industrial environments, from mechanical rooms to chemical plants.

Touchpoint Plus is supplied with As the heart of your gas detection system, Touchpoint Plus is designed to work with pre-drilled and sealed cable entries and a unique tiered internal arrangement providing ease of access to save installers time and money.

System Configuration Options Provided As Standard
  • Dedicated powered audiovisual alarm drives
  • Common alarm outputs, one for fault and two configurable
  • Datalogging to SD card
  • Remote reset and inhibit inputs
Options
  • Choice of AC or DC supply voltage
  • Optional backup battery
  • Choice of inputs: 2, 4 , or 8 mA; 2, 4 , or 8 mV; 2 mA and 2 mV; 4 mA and 4 mV
  • Optional expansion unit for up to 16 inputs
  • Choice of 12 or 24 relay outputs
  • Choice of 4 or 8 mA outputs
  • Optional RS485 Modbus RTU
  • Optional TCP/IP Modbus/HTTP

Standard outputs:

  • Three dry contact relays
    • Relay 001 – can be configured for Alarm, Fault Warning or inhibit
    • Relay 002 – can be configured for Alarm, Fault Warning or inhibit
    • Relay 003 – for Fault only
  • Four Dedicated Alarms; 24VDC output (max 300mA per channel)
    • Visible – for any status (Alarm, Fault Warning or inhibit)
    • External Alarm 1 – can be configured for Alarm 1, 2 or 3
    • External Alarm 2 - can be configured for Alarm 1, 2 or 3
    • External Alarm 3 – for Fault only

GENERAL SPECIFICATION
Capacity Up to 8 channels with base unit, up to 16 channels with expansion unit
Input Type 2- or 3-wire, mA, mV, max. 15 W per channel, max. 40 W total (with dedicated A/V drive)/68 W total (without dedicated A/V drive)
Size (Wall-Mounted Version) 426 mm × 300 mm × 156 mm (16.8” x 11.8” x 6.1”)
Housing Material Polycarbonate ABS
Weight Max. 8.5 kg (18.7 lb), max. 17 kg (37.4 lb) with expansion unit
User Interface (UI) - Controller Only
Display 7’’ color LCD touchscreen. Graphic User Interface
Visual Indicators 3 LEDs for master indicators. LED for each channel. Green: Normal; Yellow: Fault: Inhibit; Red: Alarm
Audible Alarm ≥ 70dB @ 1 m (3.28 ft)
Button Common for reset/mute operation
Language English, French, German, Italian, Dutch, Spanish, Portuguese, Russian, Chinese
Power Supply*
AC Power 110/220 VAC, 50-60 Hz Manual switching
DC Power 18 to 32 VDC (+/-10%) Typical 24 VDC
Power Consumption Max. 105 W (including detector and external devices), max. 210 W with expansion unit
Environmental
Operating -10 °C to +55 °C (14 °F to +131 °F) continuous, up to 95% RH (non-condensing), IP65, and NEMA 4X
Storage Instrument -25 °C to +60 °C (-13 °F to + 140 °F), up to 95% RH (non-condensing)
Available I/O Modules
4-20mA Input 2- or 3-wire, 2/4/8 channel modules, 10/12/16 with expansion unit
mV Input Catalytic-type flammable gas detectors (Honeywell models). 2-/4-/8-channel modules, 10/12/16 with expansion unit
Dual Input 2-channel mA + 2-channel mV module or 4-channel mA + 4-channel mV module
Relay Output 12 or 24 relay outputs, NO/C/NC changeover, 1.7 A @ 30 VDC/250 VAC, user-configurable - energized/de-energized, latching/non-latching, time delay
4-20mA Output 4 or 8 isolated repeated mA outputs, 0-22 mA, 0-100% FSD = 4-20 mA
Common Inputs Remote reset, remote inhibit
Common Outputs 4 powered A/V outputs for alarms and fault, 3 common alarm outputs
Approvals
Electromagnetic Compatibility and Electrical Safety EMC/RFI (EN 50270:2015)
LVD (EN 61010-1:2010)
CSA-C22.2 No. 61010-1-04
UL 61010-1 (3rd Edition) and 508
Performance** Designed to meet: EN 50271:2010; EN 60079-29-1:2007; EN 45544-1 /-2/-3:2015; EN 50104:2010 C22.2 No. 152-M1984, ISA 12.13.01
Safety Integrity** Designed to meet IEC/EN 61508:2010 and EN 50402:2005+A1:2008 SIL2 certification
Hazardous Location Class I, Division 2, Group A, B, C, and D, or non-hazardous only
Others
Backup Battery 22.2 V Lithium Ion Battery, 2600 mAh capacity (>30 minutes for typical system)
Datalogging Configuration, logged events, and data
Communication MODBUS TCP, WEB monitoring, and MODBUS RTU
* Basic and expansion units each require a power supply
** Contact for availability
*** Not available in expansion unit
Export Info
Harmonized Tariff Code (HTC)8531100045

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
TPPLEDWA2NNNNNN
(5826)

HONEYWELL  TPPLEDWA2NNNNNN

Extension Unit for Honeywell Touchpoint Plus Alarm Controller (up to 16 gas detection channels). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). AC or DC supply voltage. IP65. UL and CSA approvals (Class I Div 2).

100-0009-01-A
(4724)

ESP SAFETY  100-0009-01-A

ESP Safety UPES 16-channel (4-20mA) gas and flame detector controller, or 128 Modbus digital RS-485 channels (16 ports 8 channels each) for ESP Devices. Includes Modbus RS-485 output port (both analog and digital versions), power supply and 3 alarm relays and audible alert. 3Ux19" modular size, FM & ABS Class I Division 1, Ex CE and IECEx Approved.

Configure

$1,732.50 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8mA outputs. IP65. UL and CSA approvals (Class I Div 2).

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.