Simplex Tyco 4906-9102 | Horns | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SIMPLEX TYCO   4906-9102

SKU# (6851)



SIMPLEX TYCO 4906-9102

ALARM SIGNAL DEVICES / INDOOR
HORNS

  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex Tyco 4906-91XX TrueAlarm Non-Addressable multi-candela high intensity Strobe. Ceiling-Mounted. 24VDC. 1 Hz. 15, 30, 75, or 110 candela intensity selectable. High impact flame retardant housing. NEMA 1. Complies with ADA requirements. UL listed.

4906-9102   
Please Email us your request for quote   

Version

   4 Weeks  ]
Features Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount:
  • Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing
  • Operation is compatible with ADA requirements (refer to Installation Reference, Surface or Semi-Flush Wall Mounting)
  • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC)
  • Regulated circuit design ensures consistent flash output and provides controlled inrush current
  • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens
  • Listed to UL 1971 and ULC S526
  • NEMA 1 rated. See Product Selection for more information
Strobes provide synchronized flash for use with:
  • Simplex fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control
  • 4009 IDNet NAC Extenders
  • Separate strobe Synchronization Modules that are available for Class B or Class A operation
  • Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs
Strobe housings provides flexible, easy, and convenient semiflush or surface wall mounting:
  • Rear of housing does not extend into box
  • Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box
  • Ceiling mount strobes mount to single gang boxes
Optional adapters and wire guards:
  • Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to 2975-9145 boxes
  • UL listed red wire guards are available for wall or ceiling mount strobes*
Description

Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated.

Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number.

Strobe Intensity Selection

Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

Synchronized Strobes

Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules.

SmartSync Two-Wire Control

Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until- silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation).

Specifications
Rated Voltage RangeRegulated 24 VDC; see Note 1 below
Flash Rate1 Hz
Synchronized NAC LoadingUp to 35 synchronized strobes maximum per NAC
Temperature Range32° to 122° F (0° to 50° C)
Humidity Range10% to 93%, non-condensing at 100° F (38° C)
ConnectionsTerminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ); two wires per terminal for in/out wiring
Housing Dimensions (with lens)4-3/4" L x 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm)
Maximum RMS Current Rating per Strobe Setting (see Note 2 below)15 cd: 75mA
30 cd: 125mA
75 cd: 233mA
110 cd: 316mA

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    73 Items found.
BEXS120DFDC012AB1A1R
(3657)

E2S  BEXS120DFDC012AB1A1R

E2S BExS120 Flameproof and Explosion Proof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, VdS, CPD, SIL1 and INMETRO approvals.

BEXS120E_12DC
(3658)

E2S  BEXS120E12DC

E2S BExS120E flameproof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66. ATEX, IECEx, GOST-R (2ExdeIICT4), VdS, CPD, SIL1 and Inmetro Approved.

DB3BD_G_0481BNNNNN
(4227)

MEDC  DB3BDG0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. ATEX Certified, Ex d. CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,243.73 
DB3BULG_0481BNNNNN
(4229)

MEDC  DB3BULG0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. UL Hazardous & Ordinary Locations certified for Class I, Div 1. Groups A-D.

Configure

$1,243.73 
1002WEP-_24
(7224)

TOMAR  1002WEP-24

Tomar Electronics 1002WEP Explosion Proof Power Alarm Siren with 8 field selectable tones. Weatherproof construction and NEMA 4X cast aluminum housing. Class I, Div 1, Group C & D, Class I, Div 2, Groups A, B, C, & D, Class II, Div 2, Groups F & G. UL listed.

Configure

$1,254.80 
BEXDS120E_12DC
(3660)

E2S  BEXDS120E12DC

E2S BExDS120E flameproof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66. ATEX, IECEx, GOST-R (2ExdeIICT4), VdS, CPD, SIL1 and Inmetro Approved.

GNEXS1DC024AB1A1R
(6440)

E2S  GNEXS1DC024AB1A1R

E2S GNExS1 flameproof 117dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

GNEXS1RDC024AB1A1R
(6441)

E2S  GNEXS1RDC024AB1A1R

E2S GNExS1-R flameproof 115dB(A) Radial Alarm Horn Sounder with Omni-directional sound output. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

GNEXS2DC024AB1A1R
(6442)

E2S  GNEXS2DC024AB1A1R

E2S GNExS2 flameproof 123dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

STEXS1FDC024AS2A1R
(5143)

E2S  STEXS1FDC024AS2A1R

E2S STExS1F 117dB(A) Alarm Horn Sounder with re-entrant flare horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXS1RDC024AS2A1R
(6458)

E2S  STEXS1RDC024AS2A1R

E2S STExS1R 115dB(A) Alarm Horn Sounder with omni-directional horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXS2FDC024AS2A1R
(6459)

E2S  STEXS2FDC024AS2A1R

E2S STExS2F 123dB(A) Alarm Horn Sounder with re-entrant flare horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

A141DC024G
(3637)

E2S  A141DC024G

E2S A141 High Level Audible Warning System 141dB(A). High output. Ideal for wide area and disaster warning applications. 4 100W drivers. 24VDC or 230VAC Versions. IP65. GOST-R Approved.

Page: 1 | 2 | 3 | 4 | All