Certification and Specification |
ATEX Ex d Gas: |
Cert. no. Baseefa13ATEX0229X. Certified to: EN60079-0,1.
Ex II 2G, Ex d IIC T4/T5/T6 Gb |
ATEX Ex d Gas & Dust: |
Cert. no. Baseefa13ATEX0231X. Certified to: EN60079-0,1,31.
Ex II 2GD, Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. |
ATEX Ex de Gas: |
Cert. no. Baseefa13ATEX0232X. Certified to: EN60079-0,1,7.
Ex II 2G, Ex de IIC T4/T5/T6 Gb. |
ATEX Ex de Gas & Dust: |
Cert. no. Baseefa13ATEX0233X. Certified to: EN60079-0,1,7,31.
Ex II 2GD, Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. |
IECEx Ex d Gas: |
Cert. no. IECEx BAS 13.0112X. Certified to: IEC60079-0,1.
Ex d IIC T4/T5/T6 Gb. |
IECEx Ex d Gas & Dust: |
Cert. no. IECEx BAS 13.0113X. Certified to: IEC60079-0,1,31.
Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. |
IECEx Ex de Gas: |
Cert. no. IECEx BAS 13.0114X. Certified to: IEC60079-0,1,7.
Ex de IIC T4/T5/T6 Gb. |
IECEx Ex de Gas & Dust: |
Cert. no. IECEx BAS 13.0115X. Certified to: EN60079-0,1,7,31.
Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. |
UL Haz Locs: |
UL Listed for USA and Canada, fire alarm or general use, listing no. E203310.
Class I, Div 2. Groups A-D. Class I, Zone 1, Ex d IIC / AEx d IIC Gb
Class II, Div 2. Groups F&G. Zone 21 AEx tb IIIC.
Class III Div 1. |
UL Ord Locs: |
UL Listed for USA and Canada, fire alarm or general use, listing no. S8116. |
CUTR Ex d Gas: |
1Ex d IIC T4/T5/T6 Gb. |
CUTR Ex d Gas & Dust: |
1Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db. |
CUTR Ex de Gas: |
1Ex de IIC T4/T5/T6 Gb. |
CUTR Ex de Gas & Dust: |
1Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db. |
Russian Fire Approval: |
All CUTR certified units are Russian Fire Approved. |
CQST Ex d Gas: |
Ex d IIC T4/T5/T6 Gb. |
CQST Ex d Gas & Dust: |
Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db. |
Inmetro Ex d Gas: |
Ex d IIC T4/T5/T6 Gb. |
Inmetro Ex d Gas & Dust: |
Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. |
Inmetro Ex de Gas: |
Ex de IIC T4/T5/T6 Gb. |
Inmetro Ex de Gas & Dust: |
Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db IP66. |
Material |
Ex enclosure - Flame retardant, UV stable, Glass reinforced polyester. Flare - Flame retardant, high impact, UV stable, thermoplastic polyester. (UV stability tested to ISO 4892 part 3). Hardware - Bracket, fixings and captive cover screws in 316 stainless steel. |
Fire retardancy: |
Body - Glass reinforced polyester. V0 flammability rating. Outer Flare - Thermoplastic Polyester. V0 flammability rating. |
Finish: |
Body - natural black. Flare - natural black, natural red or painted as specified. (Black short flare painted black). |
Voltage: |
DC: 12 - 48V AC: Up to 254V. If using an EOL resistor with a value between 700Ω and 2KΩ the maximum voltage must be limited to 28.8Vdc, if using an EOL resistor with a value between 470Ω and 700Ω the maximum voltage should be limited to 26Vdc. |
Weight: |
Ex d/UL - 4.6kg, Ex de - 5.4kg. Based on long flare DC unit. |
Ingress Protection: |
IP66 & IP67, NEMA 4X & 6. (IPx7 & NEMA 6 on terminal chamber only). |
Earth Continuity: |
Optional for Ex de version. Not available on Ex d unit. |
Entries: |
Up to 2 x M20 or 1 / 2 ” NPT. Blanking plug available. |
Terminals: |
AC: 7 x 2.5mm2 (4 for loop in/out power, 3 for tone selection) (Standard unit only). DC: 8 x 2.5mm2 (8 for loop in/out power and tone selection) (Standard unit only). |
Mounting arrangement: |
Stainless steel bracket with ratchet facility, optional swivel bracket available. |
Labels: |
Optional duty and tag labels available. |
Tone information: |
28 tones per stage. Additional custom tones available (Contact MEDC) Suitable for use with 200Hz tones. |