Gasdetectorsusa.com: Sample Draw - All
Honeywell Analytics, Prosense, Felix Instruments, Solo, Ion Science, Spectrex, Intec Controls, E2S, RC Systems, ESP Safety, CoolAir, Portagas, Macurco, MEDC, CO2 Meter, GDS Corp, mPower, KwikDraw Uniphos, ACD
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SAMPLE DRAW > all :    18 Items found.
XP-GP-1-0-00-00
(7207)

RC SYSTEMS  XP-GP-1-0-00-00

RC Systems SampleSmart XP/ASP Sample Draw Gas Detection System for Pressure and Flow Applications. Includes SenSmart 6000 2 channel detector (for toxic and combustible gases) and flow meter with adjustable flow control valve. 24VDC. QVGA color display, RJ-45 Ethernet interface, Modbus TCP and 4 alarm relays. Optional Aspirator or Electric Pump. Aluminum or Stainless Steel housing. Class 1 Div 1.

IR-700-BR-024-P-P
(6991)

INFRARED INDUSTRIES  IR-700-BR-024-P-P

Sample Conditioner for gas detectors used as sample draw monitors, 0.5-5.0 LPM with built-in pump, 0-5 LPM rotameter with flow control valve, 3-way solenoid and rocker switch, particulate filter and water trap. Fittings and ports 1/8" NPT with 5 feet of 1/4" sample line. It does not include detector-specific flow cell adaptor.

Configure

$937.50 
SD-364-850-01
(6206)

DELPHIAN  SD-364-850-01

DELPHIAN SD Sample Draw Gas Detector and Monitoring System configured for Determinator Infrared Combustible Hydrocarbon (CHC) MultiGas Detector for up to 5 gases (5-999% LEL). Explosion proof. Includes 4-20 ma Output and 5 Digit LED Display (optional alarm relays). FMRC and CSA approvals for Class I Div 1 Groups A,B,C,D. Available gases: Acetone, Benzene, Butadiene, Butane, Butanol, Cyclohexane, Ethane, Ethanol, Ethylene, Ethylene Oxide, Gasoline, Heptane, Hexane, Iso Pentane, Isopropanol, Methane, Methanol, Pentane, Propane, Propyl Alcohol, Propylene, Styrene, Toluene and Xylene. Includes IR Determinator, calibration tool, venturi eductor or motorized pump, 3 way valve and rotameter (optional enclosure).

GDS-58DXP-0-11-06-00-00/0-0
(3327)

GDS  GDS-58DXP-0-11-06-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Carbon Monoxide (CO) with range 0-100 to 0-9999 ppm. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

GDS-58DXP-0-14-19-00-00/0-0
(3328)

GDS  GDS-58DXP-0-14-19-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Hydrogen (H2) with range 0-1% or 0-4% vol. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

GDS-58DXP-0-15-04-00-00/0-0
(3329)

GDS  GDS-58DXP-0-15-04-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Hydrogen Sulfide (H2S) with range 0-25 to 0-5000 ppm. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

GDS-58DXP-0-10-04-00-00/0-0
(3314)

GDS  GDS-58DXP-0-10-04-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Oxygen (O2) with range 0-25% Vol. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

GDS-58DXP-0-71-06-00-00/0-0
(3343)

GDS  GDS-58DXP-0-71-06-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit). Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, Ethanol, MEK, Propane, Propylene, Pentane and many others.

GDS-58DXP-0-29-05-00-00/0-0
(3336)

GDS  GDS-58DXP-0-29-05-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Nitrogen Dioxide (NO2) with range 0-50 ppm to 0-400 ppm. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

GDS-58DXP-0-19-05-00-00/0-0
(3330)

GDS  GDS-58DXP-0-19-05-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Sulfur Dioxide (SO2) with range 0-50 to 0-500 ppm. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

PQ-SMPSYS-CAT-30
(7062)

PROSENSE  PQ-SMPSYS-CAT-30

Prosense Sampling System with PQD Catalytic Bead Detector to monitor combustible gases. Includes pump, temperature control unit, 100 micron particulate and humidity filter, two solenoid valves, cooler and timer. Modbus RTU, 4-20mA, 2 Alarm and 1 Fault Relay outputs. IP65 ABS plastic enclosure. Can be calibrated to Methane, LPG Propane, Gasoline/Petrol Vapor, Butane, Pentane, Hexane, Hydrogen, Toluene, Methyl Alcohol, Heptane, Octane, Ethyl Alcohol, Iso Propanol, Ethane, Acetone, MEK, Ethyl Acetate, Amonia, Ethylene, JP8 Fuel, Benzene, Cyclo Hexane, Cyclo Pentane and other Hydrocarbons.

PQ-SMPSYS-IR-30
(7061)

PROSENSE  PQ-SMPSYS-IR-30

Prosense Sampling System with PQD Infrared Detector to monitor combustible gases. Includes pump, temperature control unit, 100 micron particulate and humidity filter, two solenoid valves, cooler and timer. Modbus RTU, 4-20mA, 2 Alarm and 1 Fault Relay outputs. IP65 ABS plastic enclosure. Can be calibrated to Methane, LPG Propane, Gasoline/Petrol Vapor, Butane, Pentane, Hexane and other Hydrocarbons.

GDS-58DXP-0-71-06-15-04/0-0
(3347)

GDS  GDS-58DXP-0-71-06-15-04/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S). Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

GDS-58DXP-0-132-02-00-00/0-0
(3346)

GDS  GDS-58DXP-0-132-02-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Carbon Dioxide (CO2) with range 0-2% v/v to 0-100% v/v. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

GDS-58DXP-0-127-06-00-00/0-0
(3345)

GDS  GDS-58DXP-0-127-06-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Ethylene Oxide (ETO) with range combustible 0-50% LEL (Lower Explosive Limit). Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.

GDS-58DXP-0-110-06-00-00/0-0
(3344)

GDS  GDS-58DXP-0-110-06-00-00/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit). Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alcohol and others.

GDS-58DXP-0-110-06-15-04/0-0
(3348)

GDS  GDS-58DXP-0-110-06-15-04/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S). Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others.

GDS-58DXP-0-132-02-10-04/0-0
(3349)

GDS  GDS-58DXP-0-132-02-10-04/0-0

GDS GDS-58DXP Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for GDS-IR Infrared Carbon Dioxide (CO2) with range 0-5% v/v or 0-3.5% v/v and Oxygen (02) with range 0-25%. Brushless DC sample pump, Fault and Low Flow Warning. 24VDC. Includes high resolution LCD Display, two 4-20mA outputs and MODBUS serial slave port. Optional relays output. CSA and UL Approved for Hazardous Locations. Class I Div 1.