Rc Systems 55001al-0-9027/100p/l0 | Voc Pid | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

RC SYSTEMS   55001AL-0-9027/100P/L0

SKU# (7120)



RC SYSTEMS 55001AL-0-9027/100P/L0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
RC Systems SenSmart 5500 3-wire gas detector for Volatile Organic Compounds VOC 10.0eV or 10.6eV with GEN2 smart sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

DISPLAY   4-20 mA   RELAYS   CSA   UL   DIV 1   HART   MODBUS

55001AL-0-9027/100P/L0   
3,398.70

Enclosure Type
Model
Output
Sensor Type
Splash Guard / Remote Sensor

   3 Weeks  ]
251 Variants of base SKU / 30 Shown below

The state-of-the-art SenSmart 5000 gas detector is R.C. Systems’ newest release to the gas detection industry. No competitive product offers as many features or better performance to cost ratio. With a bright, vivid backlit color display, Modbus and programmable relays, it will satisfy the most demanding application’s requirements. The high performance, universal gas detector supports all temperature compensated smart sensor types including Electrochemical, Catalytic Bead, Infrared and Photoionization sensors. It even has Arctic options available for extreme low temperature installations.

FEATURES HIGHLIGHT
  • CSA Certification for Class 1, Div 1 and Class 1 Div 2 locations
  • Color backlit LCD Display
  • Display Color Changes with Alarm Status
  • Generation 2 Smart Sensor Compatible for increased signal stability
  • Sensor Life Indication
  • Remote Sensor Mount up to 4000’
  • Non-intrusive One-Man Calibration
  • Temperature Compensation
  • Two RS-485 Ports for Modbus
  • 2 Programmable Relays and Fault Relay Available
  • Heated elements available for low temperature
  • Remote SmartCal feature allows user to initiate calibrations from connected RCS controller via Modbus connection

SPECIFICATIONS
Power Supply10-30VDC at < 6.5 watts with relay board (all relays energized)
Display128x64 pixel color backlit LCD display
Sensor InputElectrochemical, Catalytic Bead, Infrared, Photoionization Detector sensor, Modbus 4-20mA
Standard Output3-wire 4-20mA current source. Max loop Resistance 600 ohms @ 24VDC
Optional OutputsTwo programmable relays plus dedicated FAULT relay
Dual master / slave MODBUS RS-485 serial interfaces
EnvironmentalOperating range -40°C to +60°C Sensors include sensor heater for low temperature operation Relative humidity to 95% for IR; to 85% noncondensing when using electrochemical sensors
HousingAluminum with epoxy paint standard; Optional #316 stainless steel, Optional Ul94 Poly Black Plastic Enclosure
Dimensions(Aluminum) Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
(Poly) Width 5” (127 mm), Height 7” (178 mm), Depth 4” (101 mm) Shipping weight 3 pounds (2 kg)
ApprovalsCSA Certification for: Class I, Div1, Group A, B, C, D , Class I, Zone 1, Group IIC, T4
Class I, Div 2 Groups A, B, C, D, Class I, Zone 2, Group IIC, T4,
Warranty1 year* see standard warranty clause on our website
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    11 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
90098576
(1580)

PORTAGAS  90098576

Calibration Gas Iso-Butylene (C4H8) 100 ppm Balance Air 34 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$105.82 
10386054
(1295)

PORTAGAS  10386054

Calibration Gas Iso-Butylene (C4H8) 1000 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
10386052
(1294)

PORTAGAS  10386052

Calibration Gas Iso-Butylene (C4H8) 500 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
90301684
(1293)

PORTAGAS  90301684

Calibration Gas Iso-Butylene (C4H8) 10 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
10-9030
(7104)

RC SYSTEMS  10-9030

RC Systems 10-9030/10-9027/10-9028/10-9029/10-9561/10-9562/10-9564/10-9564 Photoionization Detector (PID) Sensor Assembly for Series 1000, 3000, 5000, 6000 Gas Detectors with ST-44 & ST-48 transmitter, Volatile Organic Compounds (VOC) 10.0eV or 10.6eV, 0-40ppm to 0-1000ppm

Configure

$2,343.54 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20 mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20 mA input channels board.

Configure

$3,525.97 
ST71P-1
(7026)

RC SYSTEMS  ST71P-1

RC Systems ViewSmart 1600+ 8 or 16-Channel Gas Detector Integral Alarm Controller with standard 5x 5A SPDT relays, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 24VDC power supply. Optional 4-20 mA inputs, 4-20 mA outputs, discrete and programmable alarm relays channels boards.

Configure

$6,217.56 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Div 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20 mA inputs.

Configure

$12,179.52 
> VOC PID :    15 Items found.
SV-8106
(7391)

PROSENSE  SV-8106

Prosense SafeVader SV-8106 Fixed Gas Detector with 10.6 eV PID sensor for Volatile Organic Compounds (VOC) with range 0-100 ppm or 0-1000 ppm. 4-20 mA Analog, Modbus RS485 RTU and relay outputs (Alarm1, Alarm2, Fault). 12 to 28VDC. ABS Plastic enclosure. IP54.

Configure

$1,834.60 
PXN-8136-1/2
(7352)

PROSENSE  PXN-8136-1/2

Prosense PXN-8136 Gas Detector with 10.6 eV PID sensor for Volatile Organic Compounds VOC with range 0-100 ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$2,151.86 
PXD-8136-1/2
(7351)

PROSENSE  PXD-8136-1/2

Prosense PXD-8136 Gas Detector with 10.6 eV PID sensor for Volatile Organic Compounds VOC with range 0-100 ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. LCD Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$2,304.28 
PQN-8136-1/2
(6965)

PROSENSE  PQN-8136-1/2

Prosense PQN-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Marine Bureau Veritas Certification, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$2,376.01 
PQD-8136-1/2
(6720)

PROSENSE  PQD-8136-1/2

Prosense PQD-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Marine Bureau Veritas Certification, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$2,546.37 
M011-0004-000
(6337)

MPOWER  M011-0004-000

mPower NEO Photo-ionization Handheld Gas Detector for Volatile Organic Compounds (VOC). Ranges from 1 ppb up to 15,000 ppm with 10.6 eV lamp (Benzene version with 9.8 eV lamp). Audible (90dB0), Visual (flashing LEDs) and wireless remote alarms. Built-in wireless modem and pump. Includes Bluetooth Low Energy (BLE) connectivity, Lithium-ion battery and USB Micro charger. Backlight display. Stainless steel housing. IP66/IP67. UL approval for Class I Div 1.

Configure

$2,752.00 
GM/BX-1-61-R0005/0-00-R000/0
(7299)

GDS  GM/BX-1-61-R0005/0-00-R000/0

GDS GASMAX BX Gas Detector for VOC (Volatile Organic Compounds) 0-5 to 0-100ppm, PID Sensor 10.0, 10.6 or 11.7eV , 3-wire. Includes 4-20mA analog output and optional 3X isolated 5A alarm relays and MODBUS interface. TFT backlit display. CSA Class I Div 1.

Configure

$3,100.00 
TV2SXBMX-X
(7402)

ION SCIENCE  TV2SXBMX-X

Ion Science TVOC 2 Fixed Detector for Volatile Organic Compounds (VOCs) 0-10 to 0-1000 ppm. MiniPID 2 sensor with 10.6eV lamp. Diffusion sampling, optional pumped version with adaptor. 5-28 VDC. 4-20 mA output. LCD display. ATEX and IECEx approvals for Zone 1 and Zone 2. IP65.

Configure

$3,322.20 
35001AL-0-9029/0010P/L0
(6896)

RC SYSTEMS  35001AL-0-9029/0010P/L0

RC Systems SenSmart 3500 3 wire gas detector for Volatile Organic Compounds VOC 0-40ppm to 0-1000ppm Isobutylene with 'ST-48' smart transmitter with 10.0eV or 10.6eV PID sensor with arctic heater. Includes Graphic LCD Display, LED indicator and 4-20 mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class I Div 1 (Explosion Proof).

Configure

$3,771.42 
TXLLSLBMR-0000
(5956)

ION SCIENCE  TXLLSLBMR-0000

Ion Science Tiger XTL handheld detector for Volatile Organic Compounds (VOCs) with PID sensor (0-5000ppm). 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger LT ***

Configure

$4,171.65 
FA2XSXBXX-3000D
(5955)

ION SCIENCE  FA2XSXBXX-3000D

Ion Science Falco 2 Fixed Detector for Volatile Organic Compounds (VOCs) in condensing atmospheres and extreme weather. MiniPID sensor in both 10.6 eV and 10.0 eV variants. Pumped or diffused versions available. RS485 Modbus, 2 x Alarm/Control Relays and 4-20 mA outputs. Includes Multi-colored status display and Robust ExD Housing. ATEX and IECEx approvals. IP65.

Configure

$4,281.90 
967-PB5520-010A
(6066)

DETCON  967-PB5520-010A

Detcon PI-700 Universal Smart Gas Sensor with Photo Ionization Detector (PID) technology for VOC 0-10ppm to 0-5000ppm. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Built-in numeric display. Water-Proof, Corrosion-Proof and Vibration-Proof. NEMA4X. IP66. CSA (Class I Div 1) and ATEX Approvals. Optional Alarm Relays, HART.

TXSXSLBMP-0517
(5957)

ION SCIENCE  TXSXSLBMP-0517

Ion Science Tiger XTS Select handheld detector for Total Aromatic Compounds (TACs) including Benzene, Toluene and Acetone with PID sensor (up to 20000ppm). 10.0 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger Select ***

Configure

$6,553.05 
TXXXSLBMP-0005
(5163)

ION SCIENCE  TXXXSLBMP-0005

Ion Science Tiger XT Select PID (photoionization) handheld detector for Volatile Organic Compounds (VOCs) with dynamic range 1ppb to 20000ppm and internal gas table with over 750 compounds. 10.6 eV Krypton lamp, optional 11.7 eV lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger ***

Configure

$6,880.65 
H-D03-0009-000
(4307)

HONEYWELL  H-D03-0009-000

Honeywell RAEGuard 2 PID Photoionization Detector for VOCs (Volatile Organic Compounds), 10.6 eV Lamp only. 10 to 28 VDC. 4-20 mA three-wire and RS-485 Modbus outputs. Explosion-proof stainless-steel enclosure. Graphic display. LED light status indicator. IP65. UL approved for Class I Div 1. (Zone 1). ATEX and IECEx also available.

Configure

$8,385.74 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.