Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
all:    431 Items found.
(6385)

BW  BWS1-V-Y

BW Solo Serviceable Single-gas Detector for Chlorine Dioxide (ClO2) 0-1 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

(6392)

BW  BWS1-XL-Y

BW Solo Serviceable Single-gas Detector for Oxygen (O2) 0-30% v/v. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

(6388)

BW  BWS1-Z-Y

BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

(4315)

HONEYWELL  C01-3012-000

DigiPID flowthough Stainless steel Adapter (included standard with all DigiPID Sensor modules) for Honeywell RAEGuard 2 PID.



$297.56 
(2127)

GDS  C2-00-090-00/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. For Electrochemical/Toxic applications. Includes 1 x 4-20 mA input channel, 2nd channel optional.



 
(355)

GDS  C2-20-010-04/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Oxygen (O2) sensor with range 0-25% Vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(365)

GDS  C2-20-011-06/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Carbon Monixide (CO) sensor with range 0-100 to 0-9999 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(368)

GDS  C2-20-014-19/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Hydrogen (H2) sensor with range 0-1% or 0-4% vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(369)

GDS  C2-20-015-04/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Hydrogen Sulfide (H2S) sensor with range 0-25 to 0-5000 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(373)

GDS  C2-20-019-05/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Sulfur Dioxide (SO2) sensor with range 0-50 to 0-500 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(376)

GDS  C2-20-029-05/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Nitrogen Dioxide (NO2) sensor with range 0-20 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(366)

GDS  C2-22-012-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Chlorine (Cl2) sensor with range 0-5 to 0-50 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(374)

GDS  C2-22-020-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Ammonia (NH3) sensor with range 0-50 to 0-1000 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(3617)

MACURCO  CM-E1-IAK

MACURCO CM-E1-IAK Installation Adapter Kit used to retrofit Macurco-2 gang type installations (CM-15, CM-15A, CM-16A, etc) to CM-E1 single gang detectors.



$19.38 
(3618)

MACURCO  CM-E1-IAK/10

MACURCO CM-E1-IAK Installation Adapter Kit (10 Pack) used to retrofit Macurco-2 gang type installations (CM-15, CM-15A, CM-16A, etc) to CM-E1 single gang detectors.



$133.98 
(6829)

BW  CP-I-00000000-Y-00

Honeywell BW Icon+ Multigas detector for up to 4 gases: Carbon Monoxide (CO) 0 to 2000 ppm, Hydrogen Sulfide (H2S) 0 to 200 ppm, Sulfur Dioxide (SO2) 0 to 150 ppm, Oxygen (O2) 0 to 30% VOL and NDIR Methane (CH4) 0 to 100% LEL available. Icon Display. Intelligent sensors. Small, lightweight and wearable. One-button operation. Visual, vibrating and audible alarms. IP66/68. Bluetooth. ATEX and IECEx approvals.

(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

(4161)

MEDC  CU1HB024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones, Zone 1, Zone 2 and non-Ex use, Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. High Temperature version. -50C to +60C. Available Certifications: ATEX, IECEx, CENELEC, GOST R and K, BASEEFA and Inmetro.

Configure

$2,342.03 
(1598)

MEDC  CU1SB024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones, Zone 1, Zone 2 and non-Ex use, Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. -50C to +50C. Available Certifications: ATEX, IECEx, CENELEC, GOST R and K, BASEEFA and Inmetro.

Configure

$2,230.51 
(4160)

MEDC  CU1SW024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones. Weatherproof only version. Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. -50C to +50C.

Configure

$2,007.50 