Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
HORNS:    89 Items found.
(6423)

E2S  E2XS1FDC024CN1A1B

E2S E2xS1F 116dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

(6424)

E2S  E2XS2FDC024CN1A1B

E2S E2xS2F 121dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
(6440)

E2S  GNEXS1DC024AB1A1R

E2S GNExS1 flameproof 117dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

(6441)

E2S  GNEXS1RDC024AB1A1R

E2S GNExS1-R flameproof 115dB(A) Radial Alarm Horn Sounder with Omni-directional sound output. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

(6442)

E2S  GNEXS2DC024AB1A1R

E2S GNExS2 flameproof 123dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

(3645)

E2S  GPH1SEDC024G

E2S GPH1 Surface Mount Alarm Horn-Buzzer 105dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66. UL and cULs Approved.

(3646)

E2S  GPH2FEDC024G

E2S GPH2 Flush Mount Alarm Horn-Buzzer 105dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 24VDC, 115VAC or 230VAC Versions. IP54. UL and cULs Approved.

(3647)

E2S  GPH3SEDC024G

E2S GPH3 Surface Mount Alarm Horn-Buzzer 110dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 10-30VDC/AC or 40-260VDC/AC Versions. IP66. UL and cULs Approved.

(4441)

E2S  GPH4FEDC024G

E2S GPH4 Flush Mount Alarm Horn-Buzzer 110dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 10-30VDC/AC or 40-260VDC/AC Versions. IP66. UL and cULs Approved.

(3587)

E2S  H100B030G

E2S H100B signalling Horn 100dB(A). Compact with high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

(3586)

E2S  H100T030G

E2S H100T signalling Horn with Trumpet 100dB(A). Compact with high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

(3593)

E2S  H110T030G

E2S H110T signalling Horn with Trumpet 110dB(A). With very high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 10-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

(3654)

E2S  HA105NDC024G

E2S HA105N Electronic Siren, Buzzer, Claxon and Bell 112dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC or 230VAC Versions. IP66. GOST-R approved.

(3648)

E2S  HA121DC024R

E2S HA121 Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66. GOST-R approved.

(3652)

E2S  HMA121DC024G

E2S HMA121 Electronic Siren, Buzzer, Claxon and Bell 124dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66 & IP67. GOST-R approved.

(3687)

E2S  IS-A105N-G

E2S IS-A105N high output Alarm Sounder 105dB(A). 16-28VDC. Stainless Steel fixings. IP66. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class I Div 1 and Class I Zone 0.

(6425)

E2S  IS-D105-G

E2S IS-D105 105dB(A) intrinsically safe Alarm Sounder. 49 alarm tones and 2 remotely selectable stages. 2 M20 entries. 24VDC. IP66. ATEX and IECEx approvals.

(3689)

E2S  IS-MA1-R

E2S IS-mA1 IS-minialarm compact Alarm Sounder 100dB(A). 16-28VDC. Stainless Steel fixings. IP65. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class I Div 1 and Class I Zone 0.

(3692)

E2S  IS-PA1-G

E2S IS-pA1 compact Panel Mount Sounder 90dB(A). 16-28VDC. Produces a high frequency continuous tone. Ideal for control panels. IP66. ATEX, IECEx and GOST-R approved.



 
Page: 1 | 2 | 3 | 4 | 5 | All


Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.