  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S BExDCS110-L1D flameproof Alarm Horn 117dB(A) and LED Beacon with 9 user selectable operation modes. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, GOST-R (1ExdIICT4) and SIL1 Approved.

BEXDCS110L1D24DC-AM   
Please Email us your request for quote   

Voltage
Lens colour
Metric Adaptor

   2 Weeks  ]
12 Variants of base SKU

The BExCS110-L1 features sound level ouputs of up to 117dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages. The beacon contains an array of 32 high output, multi-function L.E.D.s. with a total of 9 modes of operation - 4 rotating effect modes, 4 flashing modes and a steady mode for use in indicator / status applications. Based on the mode selected the user can also select two alternative L.E.D. modes remotely.

Features:
  • Glass dome with optically enhanced prismatic PC lens
  • Stainless Steel guard
  • Very large termination area.
  • Ratchet adjustable stainless steel ‘U’ bracket.
  • The sounder & beacon may be connected from a single supply for simultaneous operation or from separate supplies for independent operation
  • ‘Programmable’ version available:
    • 45 alarm tones
    • 4 remotely selectable stages
    • Any tone can be assigned to any stage
    • User configurable continuous frequency tone
Approvals:

  • ATEX certificate: KEMA 01ATEX22 23X,
    EN 60079-0 : 2 006, EN 60079-1 : 2007,
    EN 61241-0 : 2 006, EN 612 41-1 : 2004
  • IECEx certificate: IECEx KEM 10.0025,
    IEC 60079-0 : 2004 (Ed4), IEC 60079-1 : 2007 (Ed6),
    IEC 61241-0 : 2004 (Ed1), IEC 61241-1 : 2004 (Ed1)
  • GOST-R certificate: PO CC G B.JB05.B03365
  • Safety-integrity suitability: SIL1
Stage 1 WAV file Frequency Description. Stg 2 Stg 3
T 1 Continuous 1000Hz Toxic Gas Alarm T 31 T 11
T 2 Alternating 800/1000Hz at 0.25s intervals T 17 T 5
T 3 Slow Whoop 500/1200Hz at 0.3Hz with 0.5s gap repeated T 2 T 5
T 4 Sweeping 800/1000 at 1Hz T 6 T 5
T 5 Continuous at 2400Hz T 3 T 27
T 6 Sweeping 2400/2900Hz at 7Hz T 7 T 5
T 7 Sweeping 2400/2900Hz at 1Hz T 10 T 5
T 8 Siren 500/1200/500Hz at 0.3Hz T 2 T 5
T 9 Sawtooth 1200/500Hz at 1Hz T 15 T 2
T 10 Alternating 2400/2900Hz at 2Hz T 7 T 5
T 11 Intermittent 1000Hz at 0.5Hz General alarm T 31 T 1
T 12 Alternating 800/1000Hz at 0.875Hz T 4 T 5
T 13 Intermittent 2400Hz at 1Hz T 15 T 5
T 14 Intermittent 800Hz 0.25s on 1s off T 4 T 5
T 15 Continuous at 800Hz T 2 T 5
T 16 Intermittent 660Hz 150mS on, 150mS off T 18 T 5
T 17 Alternating 544Hz (100mS)/440Hz(400mS) T 2 T 27
T 18 Intermittent 660Hz 1.8s on, 1.8s off T 2 T 5
T 19 1400Hz to 1600Hz sweep up over 1s -1600Hz to 1400Hz sweep down over 0.5s T 2 T 5
T 20 Continuous 660Hz T 2 T 5
T 21 Alternating 554/440Hz at 1Hz T 2 T 5
T 22 Intermittent 554Hz at 0.875Hz T 2 T 5
T 23 800Hz pulsing at 2Hz T 6 T 5
T 24 Sweeping 800/1000Hz at 50Hz T 29 T 5
T 25 Sweeping 2400/2900Hz at 50Hz T 29 T 5
T 26 Simulated bell sound T 2 T 1
T 27 Continuous 554Hz T 26 T 5
T 28 Continuous 440Hz T 2 T 5
T 29 Sweeping 800/1000Hz at 7Hz T 7 T 5
T 30 420Hz repeating 0.625s on, 0.625s off Australian alert signal T 32 T 5
T 31 1200/500Hz at 1 Hz Prepare to Abandon Platform T 11 T 1
T 32 Sweeping 500/1200Hz 3.75s on, 0.25s off 15Hz T 26 T 1
Country specific or custom tone configurations and alarm frequencies are available upon request.

Specification
Sounder/Horn
Maximum output: 117dB(A) @ 1 metre [108dB(A) @ 10ft/3m]
Nominal output: 110dB(A) @ 1m +/- 3dB - Tone 2 [101dB(A) @ 10ft/3m]
No. of tones: 32 (UKOOA / PFEER compliant)
No. of stages: 3
Volume control: Max. 110dB(A); Min. 72 dB(A) - Tone 2
Effective range: 100m/32 8ft @ 1KHz
Voltages DC: 12 vdc; 24vdc; 48vdc
Voltages AC: 115vac; 230vac
Stage switching: Negative or positive
Beacon:
Light source: Array of 32 high output L.E.D.s
Effective Candela: 11cd* - measured ref. to I.E.S.
Lens colours: Amber, Blue, Green, Red & Yellow
Voltages DC: 10-50V dc
Voltages AC: 115 Vac; 230V ac
General:
Ingress protection: IP66/67
Housing material: Marine grade copper free LM6 Aluminium
Housing finish: Phosphated & powder coated
BExCS110-L1: Horn - High impact UL94 V0 & 5VA FR ABS (Red)
BExDCS110-L1: flare: Horn - Anti-Static High impact ABS (Black)
Cable entries: Dual M20 ISO (one stopping plug inc)
Terminals: 0.5 to 2.5mm2 cables.
Line monitoring: Min. 500 Ohm 2w, or 3k3 Ohm 0.5w res. or diode (dc versions).
Relative humidity: 90% at 2 0°C [68°F]
Weight: DC: 2.00kg/4.4Ibs AC:2 .30kg/5.06Ibs
*Candela measurements representative of performance with clear lens at optimum voltage.
*SPL data +/-3dB(A). Measured at optimum voltage.
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)8531800010

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORN + BEACON :    92 Items found.
D1xC1X10FDC024AB1A1R/A
(4415)

E2S  D1xC1X10FDC024AB1A1R/A

E2S D1xC1X10F Alarm Horn 117dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC1X10RDC024AB1A1R/A
(4416)

E2S  D1xC1X10RDC024AB1A1R/A

E2S D1xC1X10R Radial Alarm Horn 117dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X10FDC024AB1A1R/A
(4419)

E2S  D1xC2X10FDC024AB1A1R/A

E2S D1xC2X10F Alarm Horn 125dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X10RDC024AB1A1R/A
(4420)

E2S  D1xC2X10RDC024AB1A1R/A

E2S D1xC2X10R Radial Alarm Horn 118dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

CU1S_W_024F06RNNNN1BN
(4160)

MEDC  CU1SW024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones. Weatherproof only version. Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. -50C to +50C.

Configure

$2,007.50 
XB12-DB3BWN0481BNNNNN
(1620)

MEDC  XB12-DB3BWN0481BNNNNN

MEDC XB12/DB3B Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Heavy Duty Industrial & Marine Xenon 10J. Sounder up to 110dB(A). IP66 and IP67.

Configure

$2,198.99 
CU1S_B_024F06RNNNN1BN
(1598)

MEDC  CU1SB024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones, Zone 1, Zone 2 and non-Ex use, Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. -50C to +50C. Available Certifications: ATEX, IECEx, CENELEC, GOST R and K, BASEEFA and Inmetro.

Configure

$2,230.51 
CU1H_B_024F06RNNNN1BN
(4161)

MEDC  CU1HB024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones, Zone 1, Zone 2 and non-Ex use, Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. High Temperature version. -50C to +60C. Available Certifications: ATEX, IECEx, CENELEC, GOST R and K, BASEEFA and Inmetro.

Configure

$2,342.03 
STEXC1X05FDC012AS2A1R/A
(6455)

E2S  STEXC1X05FDC012AS2A1R/A

E2S STExC1X05F 117dB(A) Alarm Horn & 5 Joule Xenon Strobe Beacon with 1Hz, 1.5Hz and double flash rates. IP66 corrosion proof 316L stainless steel enclosure with guard. 3 x M20 ISO entries. Suitable for For All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXC1X05RDC012AS2A1R/A
(6456)

E2S  STEXC1X05RDC012AS2A1R/A

E2S STExC1X05R 115dB(A) Radial Alarm Horn & 5 Joule Xenon Strobe Beacon with 1Hz, 1.5Hz and double flash rates. IP66 corrosion proof 316L stainless steel enclosure with guard. 3 x M20 ISO entries. Suitable for For All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

SM87HXB+DB3D024RRA1
(4403)

MEDC  SM87HXB+DB3D024RRA1

MEDC SM87HXB/DB3 Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Explosionproof Xenon 5J; Sounder up to 115dB(A). ATEX Certified Ex II 2GD, Ex d IIC T4/T5 Gb, Ex tb IIIC T100°C/T135°C Db. IP66 and IP67. LM25.

SM87HXB+DB3BUL024RR3B
(1619)

MEDC  SM87HXB+DB3BUL024RR3B

MEDC SM87HXB/DB3B Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Explosionproof Xenon 5J; Sounder up to 122dB(A). Class I Div 1, IP66 and IP67. LM25. Available certifications: UL.

Configure

$3,581.33 
Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.