E2s D2xc1x10dc024cn1a1r/c | Horn + Beacon | Class I Div 2 And Class Ii Div 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   D2XC1X10DC024CN1A1R/C

E2S D2XC1X10DC024CN1A1R/C
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S D2xC1X10 Alarm Horn Sounder 116dB(A) and 10 Joule Xenon Strobe Beacon. Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for the harshest of hazardous location environments. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

D2XC1X10DC024CN1A1R/C   
Please Email us your request for quote   

Voltage
Cable Entries
Stopping plug/adaptor material
Bracket
Enclosure colour
Lens Color
Metric Adaptor

   2 Weeks  ]
251 Variants of base SKU / 30 Shown below

The D2xC1X10 features a high output, 116dB(A) alarm horn sounder combined with a 10 Joule Xenon strobe beacon.
One device, globally certified: ATEX, IECEx Zone 2 & 22; NEC/CEC CI D2 and CII D2; NEC CI Zone 2 and Zone 22; CEC Zone 2 & 22 and CII D2.

Low current consumption and high SPL in a robust Type 4/4X, IP66 enclosure ensure the D2xC1X10 is suitable for all haz loc general signalling applications including fire, security and process control. The corrosion proof, marine grade aluminium die cast enclosure is phosphated and powder coated providing resilience in the harshest of hazardous location environments.

Features:
  • 10 Joule Xenon beacon
  • High output, up to 116dB(A)
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching (DC units)
  • Choice of 64 alarm tone frequencies
  • Automatic synchronisation on multi-sounder system
  • Continuously rated
  • Compact form factor
  • Robust corrosion proof aluminium enclosure
  • Stainless steel fixings
  • Dual cable entries
  • Duplicate cable terminations (in & out for daisy-chain installations)
  • Available with custom tone configurations and frequencies.
  • Field changeable lens colours
Approvals:

  • UL File ref: E2 30764
    ANSI/ISA 12 .12 .01 – 2013
    CSA C2 2 .2 No. 2 13-M1987
    ANSI/UL60079-0-13
    ANSI/UL60079-15-2 013
    ISA60079-31-2 009
    CAN/CSA C2 2 .2 No. 60079-0-11
    CAN/CSA C2 2 .2 No. 60079-15-12
    CAN/CSA C2 2 .2 No. 60079-31-12
  • IECEx cert: IECEx ULD 14.0004X
    Standards:
    IEC60079-0: ed. 6.0 (2 011-06)
    IEC60079-15: ed. 4.0 (2 010-01)
    IEC60031-31: ed. 2 .0 (2 013-11)
  • ATEX cert: DEMKO 14 ATEX 4786493904X
    Standards:
    EN60079-0:2 012
    EN60079-15:2 010
    EN60079-31:2 009
Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 1000 Continuous - PFEER Toxic Gas T 3 T 2 T 44
T 2 1200/500 @ 1Hz Sweeping - DIN / PFEER P.T.A.P. T 1 T 3 T 44
T 3 1000 @ 0.5Hz (1s on, 1s off) Intermittent - PFEER Gen. Alarm T 1 T 2 T 44
T 4 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s - NF C 48-265 T 44 T 24 T 1
T 5 544(100mS)/440 (400mS) - NF S 32-001 T 52 T 19 T 1
T 6 1500/500 - (0.5s on , 0.5s off) x3 + 1s gap - AS4428 T 7 T 44 T 1
T 7 500-1500Hz Sweeping 2 sec on 1 sec off - AS4428 T 6 T 44 T 1
T 8 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) - NEN 2575 T 44 T 24 T 35
T 9 1000 (1s on, 1s off)x7 + (7s on, 1s off) - IMO Code 1a T 18 T 34 T 1
T 10 1000 (1s on, 1s off)x7 + (7s on, 1s off) - IMO Code 1a T 21 T 34 T 1
T 11 420(0.5s on, 0.5s off)x3 + 1s gap - ISO 8201 Temporal T 44 T 1 T 8
T 12 1000(0.5s on, 0.5s off)x3 + 1s gap - ISO 8201 Temporal T 44 T 1 T 8
T 13 422/775 - (0.85 on, 0.5 off) x3 + 1s gap - NFPA Temporal T 44 T 1 T 8
T 14 1000/2000 @ 1Hz - Singapore T 23 T 3 T 35
T 15 300 Continuous T 44 T 24 T 35
T 16 440 Continuous T 44 T 24 T 35
T 17 470 Continuous T 44 T 24 T 35
T 18 500 Continuous - IMO code 2 (Low) T 44 T 24 T 35
T 19 554 Continuous T 64 T 24 T 35
T 20 660 Continuous T 44 T 24 T 35
T 21 800 Continuous - IMO code 2 (High) T 44 T 24 T 35
T 22 1200 Continuous T 44 T 24 T 35
T 23 2000 Continuous T 15 T 3 T 35
T 24 2400 Continuous T 48 T 20 T 35
T 25 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent T 1 T 44 T 8
T 26 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent T 1 T 44 T 8
T 27 470 @ 5Hz (0.10s on, 0.10s off) Intermittent T 1 T 44 T 8
T 28 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent T 44 T 24 T 8
T 29 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent T 1 T 44 T 8
T 30 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent T 44 T 24 T 8
T 31 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent T 30 T 24 T 8
T 32 745 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 33 800 (0.25s on, 1.00s off) Intermittent T 53 T 24 T 8
T 34 800 @ 2Hz (0.25s on, 0.25s off) - IMO code 3.a (High) T 56 T 24 T 8
T 35 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 36 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent T 21 T 24 T 8
T 37 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent T 53 T 24 T 8
T 38 363/518 @ 1Hz (0.50s / 0.50s) Alternating T 1 T 8 T 19
T 39 450/500 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 40 554/440 @ 1Hz (0.50s / 0.50s) Alternating T 44 T 24 T 19
T 41 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating T 1 T 8 T 19
T 42 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating T 1 T 8 T 19
T 43 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating T 1 T 8 T 19
T 44 800/1000 @ 2Hz (0.25s / 0.25s) Alternating T 5 T 24 T 19
T 45 970/800 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 46 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating T 53 T 24 T 19
T 47 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating T 57 T 24 T 19
T 48 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping T 44 T 24 T 12
T 49 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping T 44 T 24 T 12
T 50 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping T 44 T 24 T 12
T 51 600/1250 @ 0.125Hz (4s / 4s) Sweeping T 44 T 24 T 12
T 52 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping T 64 T 24 T 12
T 53 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping T 56 T 24 T 12
T 54 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 55 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 56 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 57 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping T 47 T 24 T 12
T 58 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 59 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping T 44 T 24 T 12
T 60 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping T 44 T 24 T 12
T 61 800Hz Motor Siren T 44 T 24 T 12
T 62 1200Hz Motor Siren T 44 T 24 T 12
T 63 2400Hz Motor Siren T 44 T 24 T 12
T 64 Simulated Bell T 44 T 21 T 12
Country specific or custom tone configurations and alarm frequencies are available upon request.

Specification
Horn Sounder:
Maximum output: 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m]
Nominal output: 112 dB(A) @ 1m +/- 3dB - Tone 2 [103dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Adjustable -12 dB(A) [Tone 2]
Effective range: 125m/410ft @ 1KHz
Stage switching: DC units - Positive or Negative line.
AC units - common supply line
Strobe Beacon:
Energy: 10 Joules (10Ws)
Flash rate: 1Hz (60 fpm)
Peak Candela: 1,000,000 cd - calculated from energy (J)
Effective Intensity cd: 500 cd - calculated from energy (J)
Peak Candela: 101,784 cd* - measured ref. to I.E.S.
Effective Intensity cd: 288.8 cd* - measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life: Emissions are reduced to 70% after 8 million flashes
General:
Voltages DC: 24Vdc [20-28Vdc]
Voltages AC: 115Vac 50/60Hz; 230Vac 50/60Hz
Ingress protection: EN6052 9: IP66
UL50E / NEMA2 50: 4 / 4X / 3R / 13
Housing material: Marine grade aluminium Al Si12 Cu
Colour: Red (RAL3000), grey (RAL7038)
Cable entries: 2 x M20 x 1.5mm threaded gland entries
Terminals: 0.5 - 2.5mm2 (20-14 AWG)
Grounding stud: M5
Operating temp: -40 to +70°C [-40° to +158°F] - Class I Div 2
-40 to +50°C [-40° to +122 °F] - All other approvals
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 2.80kg/6.16Ibs AC:3.10kg/6.82 Ibs
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)8531800010

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORN + BEACON :    92 Items found.
E2XC1X05FAC115CN1A1B/A
(6419)

E2S  E2XC1X05FAC115CN1A1B/A

E2S E2xC1X05F Combination Alarm Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2XC1X05DC024CN1A1R/C
(4427)

E2S  D2XC1X05DC024CN1A1R/C

E2S D2xC1X05 Alarm Horn Sounder 116dB(A) and 5 Joule Xenon Strobe Beacon. Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for the harshest of hazardous location environments. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

GDS-450X-1-0/0/1-1-0
(4712)

GDS  GDS-450X-1-0/0/1-1-0

GDS GDS-450X Alarm Station Annunciator with Two Strobes and Horn. Corrosion-resistant stainless steel mounting plate. 24VDC or 110VAC configurations. Suitable for Class I Division 2 Hazardous Areas.

BEXCTS11005DR230AC-GN
(4406)

E2S  BEXCTS11005DR230AC-GN

E2S BExCTS110-05 flameproof telephone initiated and Omni-directional Alarm Horn 117dB(A) and Green Xenon Beacon. 32 selectable sounds. LM6 aluminium enclosure. 230 VAC.Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R Approved.

D2xC2LD2DC024CN0H1R/C
(6414)

E2S  D2xC2LD2DC024CN0H1R/C

E2S D2xC2LD2-H Haz Loc Synchronized Horn & LED Beacon tested to UL464 & UL1971. 24VDC. Up to 116dB(A). Up to 180cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.



 
D2xC2LD2DC024CN1A1R/C
(6415)

E2S  D2xC2LD2DC024CN1A1R/C

E2S D2xC2LD2 Haz Loc Horn & LED Beacon tested to UL1638. Up to 116dB(A). Up to 180cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2xC2XH1DC024CN0A1R/C
(6416)

E2S  D2xC2XH1DC024CN0A1R/C

E2S D2xC2XH1 auto-synchronizing Horn & 5 Joule Xenon Strobe tested to UL464 & UL1971. 24VDC. Up to 116dB(A). Up to 250cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.



 
BEXDCS11005D_24DC-AM
(3674)

E2S  BEXDCS11005D24DC-AM

E2S BExDCS110-05D flameproof Alarm Horn 117dB(A) and 5 Joule Xenon Strobe. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

D2xC2XH2DC024CN0A1R/C
(6417)

E2S  D2xC2XH2DC024CN0A1R/C

E2S D2xC2XH2 auto-synchronizing Horn & 10 Joule Xenon Strobe tested to UL464 & UL1971. 24VDC. Up to 116dB(A). Up to 500cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.



 
BEXDCS11005DR115AC-RD
(4405)

E2S  BEXDCS11005DR115AC-RD

E2S BExDCS110-05D-R flameproof Alarm Horn 117dB(A) and 5 Joule Xenon Red Strobe. Omni-directional. 115 VAC. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

BEXDCS110L1D_24DC-AM
(3677)

E2S  BEXDCS110L1D24DC-AM

E2S BExDCS110-L1D flameproof Alarm Horn 117dB(A) and LED Beacon with 9 user selectable operation modes. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, GOST-R (1ExdIICT4) and SIL1 Approved.

XB13-DB3BWN0481BNNNNN
(6047)

MEDC  XB13-DB3BWN0481BNNNNN

MEDC XB13/DB3B Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Heavy Duty Industrial & Marine Xenon 10J. Sounder up to 110dB(A). IP66 and IP67.

Configure

$1,557.17 
BEXCS11005DPFDC012AB1A1R/A
(3673)

E2S  BEXCS11005DPFDC012AB1A1R/A

E2S BExCS110-05D flameproof Alarm Horn 117dB(A) and 5 Joule Xenon Strobe. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

BEXCS11005DPRDC012AB1A1R/A
(3675)

E2S  BEXCS11005DPRDC012AB1A1R/A

E2S BExCS110-05-R flameproof Omnidirectional Horn 117dB(A) and 5 Joule Xenon Strobe. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

BEXCS110L2DPFDC024AB1A1R/A
(3676)

E2S  BEXCS110L2DPFDC024AB1A1R/A

E2S BExCS110-L2D flameproof Alarm Horn 117dB(A) and LED Beacon with 7 user selectable operation modes. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX and IECEx Approvals.

BEXCS110L2DPRDC024AB1A1R/A
(4407)

E2S  BEXCS110L2DPRDC024AB1A1R/A

E2S BExCS110-L2-R flameproof Omni-directional Alarm Horn 117dB(A) and Red LED Beacon with 7 user selectable operation modes. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX and IECEx approvals.

D1xC1X05RDC024AB1A1R/A
(4414)

E2S  D1xC1X05RDC024AB1A1R/A

E2S D1xC1X05R Radial Alarm Horn 115dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC1X05FDC024AB1A1R/A
(4413)

E2S  D1xC1X05FDC024AB1A1R/A

E2S D1xC1X05F Alarm Horn 117dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X05FDC024AB1A1R/A
(4417)

E2S  D1xC2X05FDC024AB1A1R/A

E2S D1xC2X05F Alarm Horn 125dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X05RDC024AB1A1R/A
(4418)

E2S  D1xC2X05RDC024AB1A1R/A

E2S D1xC2X05R Radial Alarm Horn 118dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.