Tyco 4906-9127 | Horn + Beacon | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

TYCO   4906-9127

TYCO 4906-9127
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Tyco Simplex 4906-9127 Multi-Candela Audible/Visible Notification with high output Xenon Strobe and Synchronized Flash. Non-Addressable. Wall or ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4906-9127   
Please Email us your request for quote   

Model

   8 Weeks  ]
4 Variants of base SKU
Audible/visible (A/V) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount
  • Operation is compatible with ADA requirements (refer to important installation information on page 3)
  • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens
Operates over a two-wire SmartSync circuit to provide:
  • Horns that are controlled separately from strobes on the same two-wire circuit
  • “On-until-silenced” and “on-until-reset” operation on the same two-wire pair
  • SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously
  • Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate
  • Class B operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938
  • Class A operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs
Wall mount A/Vs features:
  • Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing
  • Covers are available separately to convert housing color
  • Available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.)
Optional adapters and wire guards:
  • Wall mount A/V adapters are available to cover surface mounted electrical boxes and to adapt to Simplex ® 2975-9145 boxes
  • UL listed red wire guards are available for wall or ceiling mount A/Vs
Visible notification appliance (strobe):
  • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing
  • UL listed to Standard 1971
  • Regulated circuit design ensures consistent flash output and provides controlled inrush current
Audible notification appliance (horn):
  • Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern)
  • UL listed to Standard 464
Description

Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated.

Wall mount A/V housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4” square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion.

Ceiling mount A/Vs install using standard 4” electric

Strobe Intensity Selection

During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens.

Strobe Application Selection

Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

Synchronized Strobes

Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC.

SmartSync Two-Wire Control

SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as “on-until-silenced” while the strobe operation is “on-until-reset.”

A/V Specifications
Wall Mount or Ceiling Mount, Common Specifications
Rated Voltage RangeUL Listed Rating: Regulated 24 DC; see Note 1 below
ULC Listed Rating: 20 VDC to 30 VDC per ULC S526-M878
Flash Rate and Synchronized NAC Loading1 Hz; with up to 35 synchronized strobes maximum per NAC
Environmental; Temperature and Humidity32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C)
ConnectionsTerminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ); two wires per terminal for in/out wiring
Horn Output Characteristics2400 to 3700 Hz sweep, modulated at 120 Hz rate
Wall Mount Housing Dimensions (with lens)5-1/8” H x 5” W x 2-3/4” D (130 mm x 127 mm x 70 mm)
Ceiling Mount Housing Dimensions (with lens)4-3/4 L” x 6-7/8” W x 2-5/8” D (121 mm x 175 mm x 67 mm)

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
4906-9154
(7083)

TYCO  4906-9154

Tyco Simplex 4906-9154 Multi-tapped Speaker with Multi-Candela Synchronized Strobe (selectable intensity as 15 cd, 30 cd, 75 cd, or 110 cd). Non-Addressable. Rugged, high impact, flame retardant thermoplastic housing. Ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

> HORN + BEACON :    91 Items found.
HAB121RTHDC012G/R
(3651)

E2S  HAB121RTHDC012G/R

E2S HAB121RTH Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Includes beacon with 40W halogen bulb. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 12VDC. IP66.

AL121HDC024R/A
(4431)

E2S  AL121HDC024R/A

E2S AL121H Alarm Horn Sounder (A121) 126dB(A) and High Output LED Beacon (L101H). 115VAC. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AL121XDC024R/R
(3556)

E2S  AL121XDC024R/R

E2S AL121X Alarm Horn Sounder (A121) 126dB(A) and 5 Joule Xenon Strobe Beacon (L101X). 115VAC, 230VAC, 24VAC, 24VDC or 48VDC Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AB121LDADC024G/A
(3604)

E2S  AB121LDADC024G/A

E2S AB121LDA Alarm Sounder 126dB(A) and LED Beacon with 9 user selectable operation modes. Heavy duty sounder. Automatic synchronisation. Stainless Steel fixings. 24VDC, 48VDC, 115 VAC or 230VAC Versions. IP65. VdS Approved.

HAL121XAC115R/A
(5135)

E2S  HAL121XAC115R/A

E2S HAL121X Electronic Siren, Buzzer, Claxon and Bell 121dB(A) and 5 Joule Xenon Beacon. 24VDC, 115VAC or 230VAC Versions. Stainless steel fixings. IP56. GOST-R Approved.

REM-1L-R-FLASH
(5115)

COOL AIR  REM-1L-R-FLASH

Cool Air Indoor/Outdoor Remote Alarm Light & Horn Unit for LBW-50 or LBW-420 Ammonia Leak Detector. Provides a brighter light via a combination of long-life LEDs and a daybright lens. NEMA 4X box, light, horn, 24VDC. Output is 99db at 1 meter.

Configure

$541.20 
HMCA11205DC024G-AM
(3653)

E2S  HMCA11205DC024G-AM

E2S HMCA121-05 Electronic Siren, Buzzer, Claxon and Bell 122dB(A). With 5 Joules Xenon Beacon. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel guard and fixings. 24VDC or 230VAC Versions. IP66 & IP67. GOST-R approved.

MC1LD2FDC024AN1A1GA
(6826)

E2S  MC1LD2FDC024AN1A1GA

E2S MC1LD2F Alarm Sounder 117dB(A) and LED Beacon with 7 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 115VAC or 230VAC Versions. CE, RMRS Approvals.

MCA112L1DC024G-AM
(3610)

E2S  MCA112L1DC024G-AM

E2S MCA112-L1 Alarm Sounder 119dB(A) and LED Beacon with 9 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 24VAC, 115 VAC or 230VAC Versions. GOST-R Approved. ***phased out, replaced by MC1LD2F ***

HO-REM-HU-ST-24
(3696)

COOL AIR  HO-REM-HU-ST-24

Cool Air High Output Remote Alarm Horn & Strobe Unit for LBW-50 or LBW-420 Ammonia Leak Detector. NEMA 4X box. Max 117 dB(A), No Cable.

Configure

$582.20 
DL105HDC024G/A
(6463)

E2S  DL105HDC024G/A

E2S DL105H 112dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL105XDC012G/A
(6464)

E2S  DL105XDC012G/A

E2S DL105X 112dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112XDC012G/A
(6466)

E2S  DL112XDC012G/A

E2S DL112X 119dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112HDC024G/A
(6465)

E2S  DL112HDC024G/A

E2S DL112H 119dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

MC1X05FDC024CN1A1G/Y
(6925)

E2S  MC1X05FDC024CN1A1G/Y

E2S MC1X05F Alarm Sounder 117dB(A) and 5J Xenon Beacon with 1Hz flash rate. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 12VDC, 24VDC, 48VDC, 115 VAC or 230VAC Versions. GOST-R Approved.

E2XC1X05RAC115CN1A1B/A
(6420)

E2S  E2XC1X05RAC115CN1A1B/A

E2S E2xC1X05R Combination Radial Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1LD2FAC115CN1A1B/A
(6421)

E2S  E2XC1LD2FAC115CN1A1B/A

E2S E2xC1LD2F Combination Alarm Horn & LED Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1LD2RAC115CN1A1B/A
(6422)

E2S  E2XC1LD2RAC115CN1A1B/A

E2S E2xC1LD2R Combination Radial Horn & LED Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1X05FAC115CN1A1B/A
(6419)

E2S  E2XC1X05FAC115CN1A1B/A

E2S E2xC1X05F Combination Alarm Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2XC1X05DC024CN1A1R/C
(4427)

E2S  D2XC1X05DC024CN1A1R/C

E2S D2xC1X05 Alarm Horn Sounder 116dB(A) and 5 Joule Xenon Strobe Beacon. Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for the harshest of hazardous location environments. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice