Notifier P2rk | Horn + Beacon | Weatherproof | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   P2RK

NOTIFIER P2RK
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
NOTIFIER by Honeywell P2RK 2-wire horn and multicandela strobe. Wall mount. Red. 12 or 24 volts. 1 flash per second. For outdoor. NEMA 4X. IP56. UL, ULC, FM, MEA and CSFM Approvals.

P2RK   
Please Email us your request for quote   

Version

   4 Weeks  ]
2 Variants of base SKU
General

System Sensor® SpectrAlert® Advance selectable-output horns, strobes and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installation of individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes.

More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square, fourinch octagon, or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box.

Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate.

Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device will rotate into position, locking the product’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw.

SpectrAlert Advance products allow you to choose:
  • 12 or 24 volts.
  • 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of a rear-mounted slide switch and front viewing window.
  • Horn tones and volume by way of a rotary switch.
  • The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between –40°F and 151°F (–40°C and 66°C) in wet or dry applications.
Models available:
  • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe.
  • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe.
  • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire horn/strobe.
  • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire horn/strobe.
Features
  • Plug-in design.
  • Same mounting plate for wall- and ceiling-mount units.
  • Shorting spring on mounting plate for continuity check before installation.
  • Captive mounting screw.
  • Tamper-resistance capability.
  • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185.
  • Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela.
  • Outdoor wall and ceiling products.
  • Outdoor products rated from –40°F and 151°F (–40°C and 66°C).
  • Outdoor products rainproof per UL50 (NEMA 3R) and weatherproof per NEMA 4X, IP56
  • Minimal intrusion into the backbox.
  • Horn rated at 88+ dbA at 16 volts.
  • Rotary switch for tone selection.
  • Three horn volume settings.
  • Electrically compatible with existing SpectrAlert products.
Engineering Specifications

SpectrAlert Advance horns, strobes, and horn/strobes shall mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a doublegang backbox. Two-wire products shall also mount to a singlegang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12 volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F (0°C and 49°C) from a regulated DC, or full-wave-rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185.

STROBE

The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-sig- naling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe’s entire operating volt- age range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.

HORN/STROBE COMBINATION

The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector sys- tem. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non-Temporal (continuous) pattern. These options are set by a multiple posi- tion switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply.

OUTDOOR PRODUCTS

SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between –40°F and 151°F (–40°C and 66°C). The products shall be listed for use with a System Sensor outdoor/weatherproof backbox with half-inch and three-fourths-inch conduit entries.

SYNCHRONIZATION MODULE

The module shall be a System Sensor Sync•Circuit MDL3R or MDL3W listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) backbox. The module shall also control two Style Y (class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply.

Agency Listings and Approvals

The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus.

  • UL Listed: S4011 (HR__, HW__, P2__, P4__, PC2__, PC4__ models); S5512 (models SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, SRHK, SRK).
  • ULC Listed: S4011 (HRA, HRKA); S5512 (typically “A” models, with exception of outdoor strobes). See Canadian data sheet for listings and specifications.
  • FM approved
  • MEA: 452-05-E
  • CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); 7300-1653:0188 (P2_, P4_, PC2_, PC4_modules); 7135-1653:0189 (HR, HRK, HW); 7300-1653:0187 (SCRHK, SCRK, SRHK, SRK).

Operating Specifications
Standard operating temperature 32°F to 120°F (0°C to 49°C).
K Series operating temperature –40°F to 151°F (–40°C to 66°C).
Humidity range 10% to 93% non-condensing (indoor products).
Strobe flash rate 1 flash per second.
Nominal voltage Regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs.
Operating voltage range 8 V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). NOTE: P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 15/75 cd.
Input terminal wire gauge 12 to 18 AWG (3.31 to 0.821 mm²).
Ceiling-mount dimensions (including lens) 6.8" diame- ter x 2.5" deep (17.3 cm diameter x 6.4 cm deep).
Wall-mount dimensions (including lens) 5.6" H x 4.7" W x 2.5" D (14.2 cm H x 11.9 cm W x 6.4 cm D).
Horn dimensions 5.6" H x 4.7" W x 1.3" D (14.2 cm H x 11.9 cm W x 3.3 cm D).

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORN + BEACON :    92 Items found.
AL121AXXAC115R/R-UL
(5133)

E2S  AL121AXXAC115R/R-UL

E2S AL121AXX Appello X Recordable Sounder 126dB(A) and Xenon Beacon. 24VDC, 115VAC or 230 VAC Versions. Stainless steel fixings. IP66. EAC, UL & cULs approved.

HAB121RTHDC012G/R
(3651)

E2S  HAB121RTHDC012G/R

E2S HAB121RTH Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Includes beacon with 40W halogen bulb. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 12VDC. IP66.

AL121XDC024R/R
(3556)

E2S  AL121XDC024R/R

E2S AL121X Alarm Horn Sounder (A121) 126dB(A) and 5 Joule Xenon Strobe Beacon (L101X). 115VAC, 230VAC, 24VAC, 24VDC or 48VDC Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AL121HDC024R/A
(4431)

E2S  AL121HDC024R/A

E2S AL121H Alarm Horn Sounder (A121) 126dB(A) and High Output LED Beacon (L101H). 115VAC. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AB121LDADC024G/A
(3604)

E2S  AB121LDADC024G/A

E2S AB121LDA Alarm Sounder 126dB(A) and LED Beacon with 9 user selectable operation modes. Heavy duty sounder. Automatic synchronisation. Stainless Steel fixings. 24VDC, 48VDC, 115 VAC or 230VAC Versions. IP65. VdS Approved.

HAL121XAC115R/A
(5135)

E2S  HAL121XAC115R/A

E2S HAL121X Electronic Siren, Buzzer, Claxon and Bell 121dB(A) and 5 Joule Xenon Beacon. 24VDC, 115VAC or 230VAC Versions. Stainless steel fixings. IP56. GOST-R Approved.

REM-1L-R-FLASH
(5115)

COOL AIR  REM-1L-R-FLASH

Cool Air Indoor/Outdoor Remote Alarm Light & Horn Unit for LBW-50 or LBW-420 Ammonia Leak Detector. Provides a brighter light via a combination of long-life LEDs and a daybright lens. NEMA 4X box, light, horn, 24VDC. Output is 99db at 1 meter.

Configure

$541.20 
HMCA11205DC024G-AM
(3653)

E2S  HMCA11205DC024G-AM

E2S HMCA121-05 Electronic Siren, Buzzer, Claxon and Bell 122dB(A). With 5 Joules Xenon Beacon. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel guard and fixings. 24VDC or 230VAC Versions. IP66 & IP67. GOST-R approved.

MCA112L1DC024G-AM
(3610)

E2S  MCA112L1DC024G-AM

E2S MCA112-L1 Alarm Sounder 119dB(A) and LED Beacon with 9 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 24VAC, 115 VAC or 230VAC Versions. GOST-R Approved. ***phased out, replaced by MC1LD2F ***

MC1LD2FDC024AN1A1GA
(6826)

E2S  MC1LD2FDC024AN1A1GA

E2S MC1LD2F Alarm Sounder 117dB(A) and LED Beacon with 7 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 115VAC or 230VAC Versions. CE, RMRS Approvals.

HO-REM-HU-ST-24
(3696)

COOL AIR  HO-REM-HU-ST-24

Cool Air High Output Remote Alarm Horn & Strobe Unit for LBW-50 or LBW-420 Ammonia Leak Detector. NEMA 4X box. Max 117 dB(A), No Cable.

Configure

$582.20 
DL105XDC012G/A
(6464)

E2S  DL105XDC012G/A

E2S DL105X 112dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL105HDC024G/A
(6463)

E2S  DL105HDC024G/A

E2S DL105H 112dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112HDC024G/A
(6465)

E2S  DL112HDC024G/A

E2S DL112H 119dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112XDC012G/A
(6466)

E2S  DL112XDC012G/A

E2S DL112X 119dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

MC1X05FDC024CN1A1G/Y
(6925)

E2S  MC1X05FDC024CN1A1G/Y

E2S MC1X05F Alarm Sounder 117dB(A) and 5J Xenon Beacon with 1Hz flash rate. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 12VDC, 24VDC, 48VDC, 115 VAC or 230VAC Versions. GOST-R Approved.

E2XC1LD2FAC115CN1A1B/A
(6421)

E2S  E2XC1LD2FAC115CN1A1B/A

E2S E2xC1LD2F Combination Alarm Horn & LED Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1LD2RAC115CN1A1B/A
(6422)

E2S  E2XC1LD2RAC115CN1A1B/A

E2S E2xC1LD2R Combination Radial Horn & LED Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1X05RAC115CN1A1B/A
(6420)

E2S  E2XC1X05RAC115CN1A1B/A

E2S E2xC1X05R Combination Radial Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1X05FAC115CN1A1B/A
(6419)

E2S  E2XC1X05FAC115CN1A1B/A

E2S E2xC1X05F Combination Alarm Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.