E2s Is-cp4a-pt-st-nl-rd | Call Points | Zone 0, Zone 1 And Zone 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   IS-CP4A-PT-ST-NL-RD

E2S IS-CP4A-PT-ST-NL-RD
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S IS-CP4A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PT-ST-NL-RD   
Please Email us your request for quote   

Type
Terminals
B type devices only
Label
Housing Color
E.O.L. Resistor
required for IS-CP4B type
Series Resistor
required for IS-CP4B type
Metric Adaptor

   2 Weeks  ]
60 Variants of base SKU / 30 Shown below

The IS-CP4A-PT and IS-CP4B-PT push button, tool resettable, manual call points are approved for Zones 0, 1, 2, 21 & 22 requiring intrinsically safe equipment for the control of fire and gas alarm systems. Available with and without monitoring resistors all versions are certified to ATEX and IECEx standards.

The push button mechanism is protected by a spring loaded cover therefore the switch requires a two- action activation. The push button is user resettable via the use of the special key supplied with the unit. The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is phosphated and powder coated.

Options:
  • Alternative housing colours are available to meet specific requirements.
  • DIN rail mounted terminal blocks: 8 x 2 .5mm2
  • Metalised Polyester “Duty” label.
  • Series and/or End of Line resistors.
Approvals:

  • ATEX certificate: SIRA 09ATEX2 287X, EN 60079-0 : 2012 ,EN 60079-11 : 2012 , IEC 60079-26 : 2014, EN 60079-31 : 2014
  • IECEx certificate: IECEx SIR 09.012 2X, IEC 60079-0 : 2011, IEC 60079-11 : 2011, IEC 60079-26 : 2014, IEC 60079-31 : 2013
  • GOST-R certificate: POCC G B.JB05.B03365

Specification
IS-CP4A-PT: II 1G Ex ia IIC T6 Ga
II 2 D Ex t IIIC T60°C Db
IP66
Ambient: Ta = -40°C to +55°C [-40°to +131°F]
Ingress protection: IP66
Housing material: Marine grade copper free LM6 Aluminium
Housing finish: Phosphated & powder coated finish: anti-corrosion.
Colour: RAL3000 Red (others available on request)
Cable entries: 2 x M20 clearance top and 1 x M20 clearance side. Back box can be rotated to give 2 x bottom and 1 x side entries.
Stopping plugs: 2 x nylon plugs as standard Brass and stainless steel plugs optional
Terminals: 6 x 4.0mm2 cables or or 8 x 2 .5mm2 DIN rail
Weight: 0.8Kg
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)8531909000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
SM87_BGLAD_NNNNNNNNNR
(1588)

MEDC  SM87BGLADNNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA (Class I Div 1), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,458.04 
STEXCP8PBSASDN1A1R
(6461)

E2S  STEXCP8PBSASDN1A1R

E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8PMSASDL1A1R
(6462)

E2S  STEXCP8PMSASDL1A1R

E2S STExCP8-PT/M Tool Reset or Momentary Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8BGSASDN1A1R
(6460)

E2S  STEXCP8BGSASDN1A1R

E2S STExCP8-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

PH1W1B3BSNNNR
(4246)

MEDC  PH1W1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof only version. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67.

Configure

$1,691.55 
PH1B1B3BSNNNR
(4244)

MEDC  PH1B1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. ATEX, Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85°C Db. IECEx version also available.

Configure

$1,879.54 
PH1UL11M3MSNNNR
(4245)

MEDC  PH1UL11M3MSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. UL Class 1, Division 1 Gas groups B, C & D or UL Class 1, Division 2. Gas groups A - D.

Configure