Medc Bg2wnn1nr | Call Points | Weatherproof | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MEDC   BG2WNN1NR

MEDC BG2WNN1_NR

ALARM SIGNAL DEVICES / WEATHERPROOF
CALL POINTS

$324.48  [9 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. Weatherproof. IP66 and IP67.

BG2WNN1NR   
324.48

Options
Flap

   9 Weeks  ]
14 Variants of base SKU

This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where lightweight combined with a high level of corrosion resistance is required.

FEATURES

  • Zone 0, Zone 1 and Zone 2 use.
  • Exed, Exia or weatherproof.
  • ATEX approved
    • Ex II 1G (Exia)
    • Ex II 2G (Exed)
  • BASEEFA certified.
  • IP66 and IP67.
  • Certified temperature: –40°C to +50°C*.
  • Corrosion resistant red painted GRP
  • Retained stainless steel cover screws.
  • Optional lift flap.
  • Key operated test facility.
  • Lightweight and robust.
  • Breakglass hammer available. (Contact sales office for details)

Specification
Model: BG2W BG2E BG2I
Protection: Dust-tight and Weatherproof Explosion Protected Exed (Increased Safety) Explosion Protected Exia (Intrinsically Safe)
Certification: Not Applicable CENELEC EN50014, 018, 019, 028
Cert. No. BAS02ATEX2105X
ExedIICT6 (switch only)
ExedmIICT4 (other versions)
Suitable for use in Zones 1 & 2
American Bureau of Shipping Type Approval
CENELEC EN50014, 020
Cert. No. Baseefa03ATEX0084X
Exia IIC T4
Suitable for use in Zones 0, 1 & 2
Voltage: Up to 254V Up to 250V (Switch only)
Up to 24V (Resistors & Switch)
Up to 28V (IS)
Certified Temperature: –40°C to +55°C –20°C to +50°C –40°C to +50°C
Ingress Protection: IP66 & 67. IP66 & 67. IP66 & 67.
British Standard for Call Points: BS 5839 : Part 2 : 1983 (BG). BS 5839 : Part 2 : 1983 (BG). BS 5839 : Part 2 : 1983 (BG).
Switch Ratings: d.c.: 0-30V 5A (resistive) or 3A (inductive)
30V-50V 1A resistive or inductive
a.c.: 0-254V 5A resistive or inductive
NOT APPLICABLE
Resistor Values: 100R Minimum* 100R Minimum, 39k Maximum* 470R Minimum*
Cable Entries: 2 x M20 bottom.
Terminals: 6 x 2.5mm2 6 x 2.5mm2 6 x 2.5mm2
Weight: 1.2 Kg.
Material: U.V. resistant glass reinforced polyester.
Finish: Painted Red
Export Info
Made inUnited Kingdom

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
SM87_BGLAD_NNNNNNNNNR
(1588)

MEDC  SM87BGLADNNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA (Class I Div 1), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,458.04 
STEXCP8PBSASDN1A1R
(6461)

E2S  STEXCP8PBSASDN1A1R

E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8PMSASDL1A1R
(6462)

E2S  STEXCP8PMSASDL1A1R

E2S STExCP8-PT/M Tool Reset or Momentary Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8BGSASDN1A1R
(6460)

E2S  STEXCP8BGSASDN1A1R

E2S STExCP8-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

PH1W1B3BSNNNR
(4246)

MEDC  PH1W1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof only version. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67.

Configure

$1,691.55 
PH1B1B3BSNNNR
(4244)

MEDC  PH1B1B3BSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. ATEX, Ex II 2 GD, Ex d IIC T6 Gb, Ex tb IIIC T85°C Db. IECEx version also available.

Configure

$1,879.54 
PH1UL11M3MSNNNR
(4245)

MEDC  PH1UL11M3MSNNNR

MEDC PH1 Pull Handle Call Point with GRP enclosure. Exd. Weatherproof. Designed for use in flammable atmospheres and harsh environmental conditions. IP66 & IP67. UL Class 1, Division 1 Gas groups B, C & D or UL Class 1, Division 2. Gas groups A - D.

Configure

$1,879.54 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.