PROSENSE   PPS+-NO2

PROSENSE PPS+-NO2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.

PPS+-NO2
$429.00      

   3 Weeks  ]
Certified with EN 50545-1

PPS+ is the first system which acquired the certification of EN 50545-1, the standard for carparks.

Specially Designed for Carparks

Prosense PPS+ addressable gas detectors are designed and developed for continuously monitoring carbon monoxide for vehicles with gasoline and nitrogen dioxide for vehicles with diesel in closed car parks and tunnels.

Easy Communication

PPS+ Series gas detectors are managed by PPS Manager Control Panel via Modbus RS485 RTU serial connection

Increasable Number of Zones

PPS Manager Control Panel has up to four zones and each zone capable to manage up to 32 detectors.

Different Gases in Same Zone

The detectors for different gases can be integrated into same zone and can be monitored separately. Totally, 128 detectors can be managed by PPS Manager.

Suitable Solution for Ventilation System

PPS Manager has three relay outputs for each zone in order to manage fan ventilation levels. Also, 1 Alarm and 1 Fault relay contacts are integrated into the panel to monitor overall status.

Visual Indicators

Four individual LEDs in each zone inform the operator about current status as an addition to the panel display.

Power-Cut Protection

PPS Control Manager offers optional battery connections in case of power cut.

Management System Integration Output

PPS Manager provides Modbus RS 485 RTU output that can be integrated with SCADA, DCS or BMS systems.

Automatic Recognition of Detectors

PPS monitoring system automatically detects the type of detectors and adjusts the related measurement ranges and alarm levels.

Monitoring Options

You can select an average or an maximum value for every single zone and monitor that value.

Single Detector Monitoring

Monitoring every single detector in every single zone is possible with PPS Manager.

Specifications PPS+-NO2
Target Gas Nitrogen Dioxide
Sensor Type Electrochemical
Output Signal Modbus RS485 RTU
Sensor Warm-Up 60sec
Response Time/b> <30sec
Measuring Range/b> 0-30ppm
Accuracy %±1
Operating Temperature ‐20°C ~ +50°C
Humidity 5 ~ 95%RH
Input Voltage Min 10VDC - Max 18VDC - Nominal 12VDC
Power Consumption Max. 2W
Cable Entry PG11
Junction Box ABS Plastic / IP54
Dimensions 150x94,5x58mm
Weight 250gr
Standards EN 50545-1:2015 EN 50270
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
PPS+-CO
(6813)

PROSENSE  PPS+-CO

Prosense PPS+-CO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm, 0-500ppm or 0-1000ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.

Configure

$214.50 
PPS-RCO
(6811)

PROSENSE  PPS-RCO

Prosense PPS-RCO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$214.50 
PPS-LPG
(6815)

PROSENSE  PPS-LPG

Prosense PPS-LPG Addressable Gas Detector with Catalytic Bead sensor for Liquid Petroleum Gas (LPG) with range 0-100% LEL. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



$219.12 
CYL-10474555
(595)

PORTAGAS  CYL-10474555

Calibration Gas Nitrogen Dioxide (NO2) 25 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$252.43 
PPS-RNO2
(6812)

PROSENSE  PPS-RNO2

Prosense PPS-RNO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$429.00 
PPS-KP1
(6816)

PROSENSE  PPS-KP1

Prosense PPS Manager, Addressable Gas Detector Controller, Alarm Panel with up to 4 open loops (32 detectors each) for up to 128 detectors. Polycarbonate housing. LCD screen, LED Indicators (Alarm, Fan and Fault), Buzzer, 2 Fan + 1 Fault Relays for each zone and Common 1 Alarm + 1 Fault Relays; 1 Modbus RTU Output. IP66. For detection of carbon monoxide (CO), Nitrogen Dioxide (NO2) and Propane (LPG) with optional Modbus RTU addressable detectors. For Parking Garages and Tunnels.

Configure

$489.06 
> NITROGEN DIOXIDE :    27 Items found.
2100AL-0-9024/007P/L0
(237)

RC SYSTEMS  2100AL-0-9024/007P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,789.61 
S3KUL2-XNXXSN1SS
(696)

HONEYWELL  S3KUL2-XNXXSN1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring NITROGEN DIOXIDE (NO2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,789.84 
31001AL-0-9024/007P/L0
(5786)

RC SYSTEMS  31001AL-0-9024/007P/L0

RC Systems SenSmart 3100 3 wire gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,967.53 
967-646490-010
(6096)

DETCON  967-646490-010

Detcon DM-700-NO2 Electrochemical Smart Nitrogen Dioxide (NO2) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSN1SS
(847)

HONEYWELL  XNXUTAENNNNN-XNXXSN1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Nitrogen Dioxide (NO2) 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,275.97 
6100AL1-0-1024/0005P
(7012)

RC SYSTEMS  6100AL1-0-1024/0005P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class 1 Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
I-900G-NO2-0010
(7112)

INTERSCAN  I-900G-NO2-0010

Interscan GASD 8000 Portable Trace Gas Detector with smart sensor for continuous air sampling of Nitrogen Dioxide (NO2). Anodized aluminum enclosure. Includes rechargeable batteries.

Configure

$6,750.00 