Gds Rmii-00-00-00/02-50-06/1-0-1-0 | Lel Infrared | Gas Detectors (rapid Deployment) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   RMII-00-00-00/02-50-06/1-0-1-0

GDS RMII-00-00-00/02-50-06/1-0-1-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS RigMAX Single Channel Gas Monitor with Integrated strobe and 99dB horn with Infrared sensor for Methane with range 0-100% LEL (Lower Explosive Limit). Includes backlit display and 100 ft #18GA neoprene power cable. 24 VDC. Aluminium Housing and 4 point magnetic mount. CSA Certified for Class 1, Div 1, Groups B, C & D. Available calibrated to Methane (Natural Gas), Propane (LP) and other hydrocarbons. *** phased out ***

Inquiry

The RigMAX II is a single point, highly reliable and easily-deployed toxic or combustible gas monitor designed especially for onshore petrochemical monitoring applications.

Based on the GASMAX family of gas monitors widely used in onshore and offshore applications worldwide, the RigMAX II combines a gas monitor, local or remote sensor, warning strobe, horn sounder and 75 ft power cable into one convenient package.

Powered by 24VDC, the RigMAX II includes a magnetic mounting plate that makes installation a snap on any metal vertical surface. In addition, the plate is pre-drilled to support 1 1/2” pole mount U-bolt hardware or standard through-bolts.

Intuitive User Interface

The backlit LCD and highly visible LEDs display alarm status and real-time gas values or 30-minute trend data while an event log stores time-stamped calibration and alarm events for later review. An intuitive menu-driven operator interface (no blinking LEDs!) and built-in, text- prompted calibration procedure makes it easy to keep the RigMAX II operating at peak efficiency.

Flexibilty

The RigMAX II supports a wide range of toxic sensors, including Hydrogen Sulfide, Sulfur Dioxide, Hydrogen, Hydrogen Cyanide and many more, including an Hydrogen Sulfide sensor designed specifically for low humidity applications. The RigMAX II can also be configured for infrared or catalytic bead sensors to detect a wide range of combustibles. A selection of red, amber, blue or purple strobes are available for rapid recognition of any gas emergency, and the horn can be programmed to provide a range of unique warning tones.

The RigMAX II is a convenient and easy solution for toxic gas monitoring in rough field conditions where reliability and rapid installation are critically important.

FEATURES

  • Robust, highly reliable single-point monitor for Hydrogen Sulfide gas
  • Integrated warning strobe and 99 dB horn provide quick response
  • Local or remote sensor with optional high visibility stand
  • Four-point magnetic mount makes installation quick and easy
  • Easy-to-use prompted calibration for rapid setup and commissioning
  • Fault supervision circuitry detects failed or missing sensor element
  • Backlit display for better visibility at night or in low light conditions
  • Security software lock prevents tampering or resetting alarms
  • Automatic recognition of GDS Corp Smart Sensors
  • Built-in Event Log records alarms, power cycles and calibrations
  • Includes 100 ft #18GA neoprene power cable wth flying leads
  • Remote sensor includes jbox, cable glands and 10’ neoprene cable
  • Manufactured in USA

RIGMAX II SPECIFICATIONS
Power Input: +24VDC ± 10% at less than 10 watts
Display GASMAX II gas monitor with backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units. Alarm LEDs show Alarm 1, Alarm 2 and Fault.
Sensor Input Local or remote toxic sensor for oxygen, carbon monoxide, chlorine, hydrogen, hydrogen sulfide (normal and low humidity), sulfur dioxide, ammonia and mercaptan.
Catalytic bead or Infrared sensor for detection of combusible levels of hydrocarbons or hydrogen Photoionization detector (PID) for detection of benzene, toulene and other volatile organic compounds in low ppm levels.
Output Alarm 1 Ouput: High visibility 24V strobe in red, amber, blue or purple. Sixty to 80 flashes per minute; 10,000 hour strobe lamp; 1.9 joules / flash; 190,000 candlepower.
Alarm 2 Output: Horn sounder, 91-97 dB at 10 feet. Eight user selectable tones: horn, chime, siren, slow whoop, temporal, hi-lo and single stroke bell.
Temp -10°C to +50°C operating range
Housing Aluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)
Mounting Four-point magnetic mount designed for flat surface. Mounting plate drilled for 2” pole mount and standard through-bolts
Dimensions Local Sensor: Width 11” (280 mm), Height 18” (457 mm), Depth 5” (127 mm)
Shipping weight 9 pounds (3 kg)
Approvals GASMAX CSA Certified for Class I, Div 1, Grps B, C, D.
Optional Class 1 Div 2 rated strobes
Horn sounder not for use in hazardous areas
Warranty 2 years on electronics and one year on sensors
> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

10-9570-R06
(342)

GDS  10-9570-R06

Catalytic Smart LEL sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit).



 
1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

> LEL INFRARED :    25 Items found.
XNXUTAINNNNN-2108N4110
(851)

HONEYWELL  XNXUTAINNNNN-2108N4110

Honeywell XNX Universal Gas Detector Transmitter with Optima Plus Infrared Hydrocarbon Gas Detector combustible 0-100% LEL (Lower Explosive Limit) and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2 . Available for over 100 gas and vapour calibrations.

Configure

$3,478.59 
2108N5110N
(1966)

HONEYWELL  2108N5110N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for gas ranges 0–100 %v/v Methane (CH4), 0–600,000 ppm Propane (C3H8) and 0–400,000 ppm Propane (C3H8). 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration fitted with remote gassing cell and flow housing.

Configure

$3,571.00 
3300MAL-0-0498/100L/L0
(7039)

RC SYSTEMS  3300MAL-0-0498/100L/L0

RC Systems SenSmart 3300M 3 wire gas detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-48' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof). Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,518.18 
6300MAL-0-0498/100L/L0
(7041)

RC SYSTEMS  6300MAL-0-0498/100L/L0

RC Systems SenSmart 6300M 3 wire Dual Channel Gas Detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-44' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66. Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,940.25 
GD10-PE0-17DE-0XH-00
(3083)

SIMTRONICS  GD10-PE0-17DE-0XH-00

Simrad GD10PE IR Extended Point Gas Detector for Methane (CH4) 0-20% LEL for offshore installations. 4-20 mA output with HART. 24 VDC. IP66 and IP67. Available Approvals: UL Class I Division 1, ATEX, CSA, IECEx, INMETRO and SIL.

Page: 1 | 2 | All