Macurco Tx-12-hs | Hydrogen Sulfide | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   TX-12-HS

MACURCO TX-12-HS
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MACURCO TX-12-HS line voltage Gas Detector, controller and transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

TX-12-HS   
656.26

Voltage
Housing Color

   2 Days  ]
2 Variants of base SKU

The Macurco 12-Series are line voltage (100-240VAC), dual relay gas detector, controller and transducers. The 12-Series utilizes an internal switching power supply that is capable of using line voltage between 100 and 240VAC and 50-60Hz. The 12-Series have selectable 4-20mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of various gases and provide feedback and automatic control to help reduce gas concentrations in parking garages, maintenance facilities or other commercial applications.

Selectable options include:
  • Selectable relay actuation levels
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Buzzer, digital display, latching relay, relay delay, relay minimum runtime
Features:
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Supervised system design: detector problem will cause relay activation
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
12-Series Rear View

Specifications:
Power: 100-240VAC (50 TO 60 HZ)
Current: 1.0 A MAX
Shipping Weight: 1 pound (0.45 kg)
Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Color: Dark gray
Connections: plugs/terminals
Mounting box: (not included) 4x4 electri
Fan relay: 5A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation: Selectable within sensor range
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Runtime settings OFF (default), 3, 5, 10 or 15 minutes
Alarm relay: 0.5A 120 V, 60 VA
Alarm relay actuation: selectable N.O. default or N.C.
Alarm relay settings: Selectable within sensor range
Current Loop 4-20 mA
Operating Environment: 0°F to 125° F (-18°C to 52°C).10 to 90% RH
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
CX/TX-CH
(2117)

MACURCO  CX/TX-CH

MACURCO Calibration Hood/cup for CX, TX, OX, & RD series gas detectors: ammonia (NH3), hydrogen sulfide (H2S) and Nitrogen Dioxide (NO2).



$33.38 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
70-2900-0605-4
(2527)

MACURCO  70-2900-0605-4

MACURCO TX-6-HS (TX-12-HS) Hydrogen Sulfide H2S Replacement sensor. (Replaces 26-2900-0006-5)

Configure

$212.16 
Cal-Kit 2*H2S GAS 25PPM
(2997)

MACURCO  Cal-Kit 2*H2S GAS 25PPM

Macurco Macurco Cal-Kit 2 Hydrogen Sulfide (H2S) 25 ppm gas field calibration kit to calibrate Macurco TX-6 fixed gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood. 1/cs. 30-0021-1110-1 & 70-2900-0010-9.



$624.02 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
> HYDROGEN SULFIDE :    38 Items found.
1100ALD-109022/0010P-L0
(6914)

RC SYSTEMS  1100ALD-109022/0010P-L0

RC Systems SenSmart 1100 gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
GG-H2S-50-EXP
(5979)

CALIBRATION TECHNOLOGIES  GG-H2S-50-EXP

CTI GG-H2S-50-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen Sulfide (H2S) 0-50 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,341.51 
SPXCDULNHX
(663)

HONEYWELL  SPXCDULNHX

Honeywell XCD Sensepoint Gas Detector, Hydrogen Sulfide (H2S) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen sulfide (H2S) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. 0-50 ppm range. User-Selectable full scale range 10.0 to 100.0ppm. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,379.12 
965-015420-100
(5007)

DETCON  965-015420-100

Detcon MicroSafe TP-524D Smart gas detection Sensor designed to detect and monitor Hydrogen Sulfide (H2S) with range 0-100ppm using solid state metal oxide semiconductor technology. Aluminum Junction Box. 4-20mA output. LED Display. Explosion Proof. IP66. ATEX, ISA and CE Approved. CSA and FM Approved for Class I, Division 1, Groups B, C, & D.

100-0008-SS/100-0015-H2S
(4754)

ESP SAFETY  100-0008-SS/100-0015-H2S

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Hydrogen Sulfide (H2S) 0-20, 0-50 or 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
S3KUL2-XNXXSH1SS
(695)

HONEYWELL  S3KUL2-XNXXSH1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN SULFIDE (H2S) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-15ppm, 0-100ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,491.53 
41001AL-0-1022/0005P/L0
(7167)

RC SYSTEMS  41001AL-0-1022/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1022/0005P/L0
(7122)

RC SYSTEMS  51001AL-0-1022/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-240026-100G
(2132)

DETCON  961-240026-100G

Detcon DM-100-H2S Electrochemical Hydrogen Sulfide (H2S) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

967-242490-100
(6064)

DETCON  967-242490-100

Detcon DM-700-H2S Electrochemical Smart Hydrogen Sulfide (H2S) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNH2
(5104)

HONEYWELL  SPXCDULNH2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen Sulfide (H2S) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
967-011520-100
(4717)

DETCON  967-011520-100

Detcon TP-700 non-intrusive Smart Sensor for Hydrogen Sulfide (H2S) 0-100ppm using a solid state metal oxide semiconductor MOS technology. Aluminum or Stainless Steel Junction Box. 4-20mA and Modbus RS-485 outputs. LED Display. Explosion Proof. IP66. CSA, ATEX, CE and SIL2 Approved.

2100AL-0-9022/0010P/L0
(126)

RC SYSTEMS  2100AL-0-9022/0010P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
966-014520-100
(6101)

DETCON  966-014520-100

Detcon TP-624D Hydrogen Sulfide (H2S) 0-100ppm Smart Sensor with solid state metal oxide semiconductor technology. Includes MOS detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. ATEX and CSA approval for Class I, Division 1, Groups B, C & D.

XNXUTAENNNNN-XNXXSH1SS
(846)

HONEYWELL  XNXUTAENNNNN-XNXXSH1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Sulfide (H2S) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-15ppm, 0-100ppm

Configure

$1,963.60 
31001AL-0-9022/0010P/L0
(5784)

RC SYSTEMS  31001AL-0-9022/0010P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1(Explosion Proof).

Configure

$1,967.53 
6100AL1-0-1022/0005P
(7009)

RC SYSTEMS  6100AL1-0-1022/0005P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
QTU-QRU-C-111
(6855)

SPECTREX  QTU-QRU-C-111

SPECTREX SafEye Quasar 950 open path gas detector and source with ultraviolet technology to detect toxic Hydrogen Sulfide (H2S) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$29,843.47 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.