Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

2108N4000N   
2,123.32

Remote Gassing Cell
HART Output
Certification
Calibration (ATEX)
Please select one curve only
Calibration (UL)
Please select one curve only
Calibration (UL)
Please select one curve only
Calibration (UL)
Please select one curve only

   12 Weeks  ]
12 Variants of base SKU
2108N4000N contains : 2108B2001 and it also includes Dust Barrier 2108B0259, Deluge and Heat Shade 2108D0275, Weather housing 2108B0276, fully assembled and tested as a complete unit.

Largest selling point IR hydrocarbon gas detector in the world.

Advanced infrared point gas detector

FEATURES

Why Searchpoint Optima Plus is the right choice...
  • The proven strengths of the original Searchpoint OPTIMA design
  • Experience gained from over 30,000 units installed worldwide
  • The latest technology and techniques used to develop the successful Sieger open path gas detector, the Searchline Excel
  • Improved reliability
Why Infrared?
  • Failsafe operation
  • Fast speed of response
  • Reduced routine maintenance
  • Immune to catalytic poisons
  • Long operating life
  • Works in inert atmospheres
Why Searchpoint Optima?
  • Can detect a wide range of hydrocarbon gases including solvents
  • Increased reliability with no moving parts
  • Increased stability from self compensating optics
  • Immune to long term component drift
  • Remote functional gas test facility
  • Certified for North American and European Hazardous areas
Why Searchpoint Optima Plus?
  • Increased false alarm rejection with ✔2 SOFTWARE™
  • Increased uptime with contaminated optics warning
  • Dynamic Heating Control ensures condensation free optics
  • No undetected failures
  • Improved diagnostics
  • Integral event logging
  • Reduced power consumption
  • Certified to many hazardous area classification schemes including: European (ATEX), UL, CSA and more
Optics Block

The 4-channel (dual compensated) optics-block is the heart of the Searchpoint OPTIMA PLUS. It is specifically designed to compensate for changes in the external environment similar to 2- channel designs, but also compensates for long term component drift such as infrared sources and detectors. This combined with the de-focussed beam provides the Searchpoint OPTIMA PLUS with the most stable optics design possible.

Searchpoint Optima Plus Specification
Output
Measuring range 4-20 mA sink or source, (Default current source)
Inhibit 1-3 mA (Default 2 mA)
Warning 0-4 mA (Default 4 mA)
Fault 0 mA
Over range 20-21.5 mA (Default 21 mA)
Digital Output Optional Multidrop Modbus RS485 (via DVC/DX100(m))
Material 316 stainless steel
Weight 1.6 kg
Accuracy
Optima PLUS (HC) Baseline < ±1% LEL, 50% FSD <±2% LEL
Optima PLUS (ET) Baseline < ±2% LEL, 50% FSD <±3% LEL
Repeatability < ±2% LEL at LEL 50% FSD
Linearity < 5% FSD
Response time T50 < 4.5 seconds, T90 < 6.5 seconds (for methane, including weather protection)
Operational and certified -40°C to +65°C temperature range
Drift with time and over temperature range -40°C to +65°C
Baseline < ±2% LEL
50% FSD < ±4% LEL
Variation with pressure 0.1% (of reading) per mbar
Power supply 18-32 V (24 V nom) DC, < 4.5 W max
Environmental protection IP 66/67
Diagnostics (and re-calibration) Via certified Hand Held Interrogator
Safety approvals

ATEX,
II 2 G EEx d IIC
   T5 (Tamb -40°C to +55°C)
   T4 (Tamb -40°C to +65°C)
UL/CSA Class 1, Div 1, groups B, C, and D (-40°C to +65°C)
GOST and SAA

Performance approvals EN50054, EN50057, CSA C22.2 152.
EMC compliance EN 50270
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    11 Items found.
2108B0259
(1975)

HONEYWELL  2108B0259

Dust Barrier for Honeywell Optima Plus.



$110.94 
CYL-90095187
(6713)

PORTAGAS  CYL-90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90090227
(1313)

PORTAGAS  CYL-90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10624200
(1305)

PORTAGAS  CYL-10624200

Calibration Gas Propane (C3H8) 50% LEL 1.06%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
2108D0275
(1980)

HONEYWELL  2108D0275

Deluge / Heat Shade for Honeywell Optima Plus



$218.76 
2108B0276
(1976)

HONEYWELL  2108B0276

Weather housing for Honeywell Optima Plus.



$384.65 
(4709)

HONEYWELL  OPTIMACALKIT

Honeywell Optima Plus calibration kit, 3/16" ID Tubing, gas cover, C-10 inlet regulator for Optima without RGC Remote Gassing Cell (contains 998-100-004 tubing, 2108D0258 gas cover, 998-100-002 C-10 regulator (2LPM), W/GAS CELL), 998-100-003 carrying case. Calibration gas cylinder not included-



$709.17 
XNXUTAINNNNN
(1944)

HONEYWELL  XNXUTAINNNNN

Honeywell XNX Universal Display and Transmitter for IR infrared input compatible with Optima Plus and Excel Open Path sensors, with aluminum alloy LM25 housing (optional stainless steel), 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs, UL, ATEX or INMETRO certified.

Configure

$982.65 
04200-A-1015
(1971)

HONEYWELL  04200-A-1015

Optima duct mounting kit for Honeywell Optima Plus. Use only with ATEX and SAA Versions



$1,301.12 
2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$2,123.32 
04230-A-1001
(1981)

HONEYWELL  04230-A-1001

Hand Held Interrogator ATEX SHC-1 Certified (4V0 software) for Optima, Optima Plus and Excel



$2,665.09 
> LEL INFRARED :    23 Items found.
3300MAL-0-0498/100L/L0
(7039)

RC SYSTEMS  3300MAL-0-0498/100L/L0

RC Systems SenSmart 3300M 3 wire gas detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-48' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof). Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,518.18 
6300MAL-0-0498/100L/L0
(7041)

RC SYSTEMS  6300MAL-0-0498/100L/L0

RC Systems SenSmart 6300M 3 wire Dual Channel Gas Detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-44' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66. Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,940.25 
GD10-PE0-17DE-0XH-00
(3083)

SIMTRONICS  GD10-PE0-17DE-0XH-00

Simrad GD10PE IR Extended Point Gas Detector for Methane (CH4) 0-20% LEL for offshore installations. 4-20 mA output with HART. 24 VDC. IP66 and IP67. Available Approvals: UL Class I Division 1, ATEX, CSA, IECEx, INMETRO and SIL.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.