Macurco Gd-6 | Lel Catalytic Bead | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   GD-6

MACURCO GD-6
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, CSA Approved.

GD-6   
481.90

Voltage
Modbus RS-485 Adapter
Housing Color

   2 Days  ]
2 Variants of base SKU
Features
  • 5A Control relay
  • 0.5A Alarm Relay
  • Digital Display
  • Internal Buzzer
  • 4-20mA current loop
  • DVP-120 compatible
  • ETL Listed
  • 5 year sensor
Applications

Methane, Propane, Hydrogen, battery charging, warehouses, vehicles, landfills, repair facilities, golf carts, battery back-up

Mode: Stand Alone or System
Area: 900 ft2 (84 m2)

The GD-6 is a versatile, easy-to-use device that allows you to select between methane, propane or hydrogen gas detection. It provides low-level detection of combustible gas in an easy-to-maintain monitor that is factory calibrated for simple installation.

This low voltage detector provides automatic feedback and fan control that can help reduce combustible gas concentrations in parking garages, maintenance facilities, and other locations that require combustible gas detection.

Selectable options include:

  • Measurement: Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2)
  • Output: Fan relay, alarm relay and 4-20 mA current loop
  • Controls: Digital display (0-50% LEL), buzzer, fan delay, fan minimum run time

The GD-6 is an advanced combustible gas detector with the selectable options that make it an effective solution for multiple applications that need an accurate combustible gas detector.

Combustible Gas Detection

  • Measures Methane (NG), Propane (LP) or Hydrogen (H2)
  • Low level meter capable of displaying from 0-50% LEL EX or Lower Explosive Limit

Display, Control & Calibration

  • Selectable (on/off) digital display, buzzer, fan delay (minutes), fan minimum run time
  • Selectable fan and alarm relay activation
  • Factory calibrated. Can also be field calibrated using 10% LEL Methane, 10% LEL Propane or 10% LEL Hydrogen gas, regulator and calibration hood
  • One screw allows access for calibration

Installation

  • Mounts on a standard 4" x 4" electrical box, no cover needed
  • 5 A SPDT fan relay controls starters of exhaust fans
  • 0.5 A N.O. or N.C. alarm relay connects to warning devices or control panels
  • 4-20 mA current loop
  • Optional calibration kits allow the GD-6 to be tested and field calibrated using Methane, Propane or Hydrogen gas

Other Features

  • Supervised system design: internal detector problem will cause the fan & alarm relay to activate
  • ETL Listed to UL 61010-1

Typical Connection to Alarm Control Panel

  • GD-6 can be used with 12VDC or 24VDC N.O. (fire) panels
  • Alarm panel provides battery backed up power to GD-6
  • GD-6 dry contact fan relay can use panel power or fan power. Check ratings on panel and fan
  • Match fan relay contacts to fan size, and coil voltage to power source
  • Alarm control panels are available with many features and can control other devices such as smoke detectors, fire detectors and burglar alarms

UPC 0 00 51131 49886 0
Accuracy ±5% of the LEL reading up to 50% LEL
Power 3 W (max) from 12 to 24 VAC or 12 to 48 VDC
Current @ 24VDC 75 mA in alarm (two relays), 50 mA (fan relay only) and 23 mA stand by
Shipping Weight 1 pound (0.45 kg)
Size 4.5 x 4 x 2.125 in. (11.4 X 11.4 X 5.3 cm)
Color Dark gray
Connections Plugs/terminals
Mounting Box (Not included) 4x4 electric
Fan Relay 5 A, 240 VAC, pilot duty, SPDT
Fan Relay Actuation Selectable at 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 (default),11, 12, 13, 14, 15, 16,17, 18, 19, 20% LEL
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Run Time Settings are OFF (default), 3, 5, 10, 15 minutes
Alarm Relay 0.5A 200 V, 10 VA
Alarm Relay Actuation Selectable N.O. default or N.C.
Alarm Relay Settings OFF, 5, 10, 15, 20 (default), 25% LEL
Current Loop 4-20 mA for 0-50% LEL
Operating Environment 0° F to 125° F (-18° C to 52° C) 10 to 90% RH
Sensor Life 5 years
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
GD-CH
(1863)

MACURCO  GD-CH

MACURCO Calibration Hood/cup for GD-6/12 combustibles LEL gas detector



$33.38 
MRS-485
(2947)

MACURCO  MRS-485

MACURCO Modbus RS-485 Slave Adapter for use with Macurco 6-Series gas leak detectors to convert the 4-20mA analog signal from Macurco 6-Series type detectors to a Modbus digital signal for use with multipoint addressable systems and control panels such as the DVP-120M. Plugs into the back of the detector.



$118.05 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
Cal-Kit 1*CANN10P
(2995)

MACURCO  Cal-Kit 1*CANN10P

Macurco Cal-Kit 1 Propane (C3H8) 10% LEL / 20% LEL gas field calibration kit to calibrate Macurco GD-6 fixed gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood 2ft. 1/cs. 30-0021-1110-2.

Configure

$468.23 
Cal-Kit 1*CANN10M
(2994)

MACURCO  Cal-Kit 1*CANN10M

Macurco Cal-Kit 1 Methane (CH4) 10% LEL / 20% LEL gas field calibration kit to calibrate Macurco GD-6 fixed gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood. 1/cs. 30-0021-1110-2.

Configure

$468.23 
Cal-Kit 1*CANN10H
(2993)

MACURCO  Cal-Kit 1*CANN10H

Macurco GDH-FCK Hydrogen (H2) 10% LEL / 20% LEL gas field calibration kit to calibrate Macurco GD-6 fixed gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood. 1/cs. 30-0021-1110-2.

Configure

$468.23 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
DVP-120M
(3973)

MACURCO  DVP-120M

Macurco DVP-120M Addressable Detection and Ventilation Panel. Modbus-Enabled with up to 87 Modbus RS-485 addressable sensors on three channels of 29 sensors per channel. Features 12 4-20mA sensor inputs (for a total of 99 channels) , three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,444.88 
> LEL CATALYTIC BEAD :    27 Items found.
52001AL-0-9070/100P/L0
(7121)

RC SYSTEMS  52001AL-0-9070/100P/L0

RC Systems SenSmart 5200 3-wire gas detector with Catalytic Bead sensor for Hydrocarbons and Hydrogen (ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, pentane, propane, propene, propylene) 0-100% LEL with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
XNXUTAVNNCB1
(852)

HONEYWELL  XNXUTAVNNCB1

Honeywell XNX Universal Gas Detector Transmitter including MPD CATALYTIC BEAD sensor combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2, INMETRO

Configure

$1,728.46 
XCDRFDL
(3004)

HONEYWELL  XCDRFDL

Honeywell Sensepoint XCD RFD (Remote Flammable Detector) Kit. Includes transmitter with LM25, 3/4“NPT Entry, 705 sensor, and 3 wire junction box. Tri-colour backit display. Outputs include 2 programmable alarm relays, 1 programmable fault relay, 4-20mAoutput (sink or source selectable). Sensor can be mounted up to 30 metres (100 feet) from transmitter. cCSAus Certified for North America. Class 1, Div 1, Groups B, C, & D.

Configure

$1,734.98 
967-521520-100
(5005)

DETCON  967-521520-100

Detcon FP-700 non-intrusive Smart Sensor designed to detect and monitor combustible gases with range 0-100% LEL using catalytic bead sensor technology. Aluminum or Stainless Steel Junction Box. 4-20mA and Modbus RS-485 outputs. LED Display. Explosion Proof. IP66. CSA, ATEX, CE and SIL2 Approved.

966-524520-100
(6100)

DETCON  966-524520-100

Detcon FP-624D Combustible 0-100% LEL Smart Sensor with catalytic bead. Includes detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. CSA approval for Class I, Division 1, Groups C & D.

32001AL-0-9071/100P/L0
(6894)

RC SYSTEMS  32001AL-0-9071/100P/L0

RC Systems SenSmart 3200 3 wire gas detector with Catalytic Bead sensor for Hydrocarbons and Hydrogen (ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, pentane, propane, propene, propylene) 0-100% LEL with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
6200AL1-0-109070/100P
(7019)

RC SYSTEMS  6200AL1-0-109070/100P

RC Systems SenSmart 6200 3 wire Dual Channel Gas Detector for Hydrocarbons and Hydrogen Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
Page: 1 | 2 | All