Honeywell XNX Universal Gas Detector Transmitter for monitoring Nitrogen Dioxide (NO2) 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Part# with Options:        XNXUTAENNNNN-XNXXSN1SS
Price with Options:        2,004.78

Options:    

Agency Approval & Port Threads
(1) Honeywell XNX Transmitters
Enclosure
(2) Honeywell XNX Transmitters
Interface option
(3) Honeywell XNX Transmitters Output Option
Local HART Port
(4) Honeywell XNX Transmitters
Custom Tag
(5) SSTAG Stainless Steel Custom Tag for Honeywell Gas Detectors

  Availability 4 Weeks  ]

The XNX Universal Transmitter marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs.

FEATURES

High performance
  • Flammable gas detection 0 to 100% LFL/LEL
  • Point IR with heated optics provides immunity to poisoning and no hidden faults
  • Open-path IR flammable gas detection in LEL-m measurement
  • Electrochemical cell offers toxic gas detection in ppm
  • IR cell provides CO2 and combustible gas monitoring
  • Robust and reliable operation in explosive areas and harsh environments
Flexible Operation
  • 3 versions - supports mV (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection
  • Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability
  • 4-20mA with HART® as standard
  • Multiple communications options include up to 3 relays, MODBUS® and FOUNDATION® H1 Fieldbus (pending)
  • Optional local IS port for handheld HART configurator
Easy to Use
  • Large, backlit, easy-to-view LCD display offers multisensory indicators (visual icons, colored buttons, text, etc.) to display gas and sensor readings
  • User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese)
  • Self-test and fault indication features
  • Non-intrusive, one-man operation
  • Quick calibration with auto-inhibit
Easy to Install
  • 3 or 4 wire operation, source, sink or isolated
  • Use with conduit or cable installations
  • Simple plug-in sensors and replaceable cells
  • NEMA 4X IP66 rated for rugged indoor/outdoor use
Cost Effective
  • Minimal training required
  • One-man operation
  • Plug-in sensor replacement
  • All necessary accessories included
Applications
  • Offshore Oil & Gas production platforms
  • Onshore Oil terminals
  • Refineries
  • Gas Transmission
  • Gas Distribution
  • LNG terminals
  • Gas storage terminals
  • Chemical plants
  • Petrochemical plants
  • Solvent recovery operations

XNX is designed for flexible integration, simple installation, user friendly operation and straightforward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. Users are assured of being protected in all conditions with Honeywell Analytics gas monitoring solutions.

Bringing together the best solutions in gas detection

Electrochemical
  • Proven electrochemical sensing technology
  • Surecell™ electrochemical cells are ideal for hot and humid environments
  • Long life sensing cells (typical >2 years)
  • Patented 'Reflex' sensing element verification diagnostics
  • Sensor recognition software auto configures transmitter
  • Plug and play factory configured sensors
  • Intrinsically safe sensor connection permits hot swap, reducing down time
XNX Surecell Electrochemical sensors

XNX's modular design enables Honeywell Analytics to offer appropriate, cost effective solutions to a wide range of gas detection requirements.

With the XNX, you are freed from the need to add extra controllers, junction boxes, relays, monitors and other equipment accessories.

The XNX Universal Transmitter is an excellent choice for those who want a total integrated monitoring and safety solution for an industrial plant.

The XNX's powerful advanced communications module adds increased functionality and flexibility to a gas detection network. Standard HART communications, along with optional Modbus, Foundation Fieldbus (pending) or relays, interface with a PLC and a host of other protocol compatible devices found in industrial applications.

XNX Output Options

Back-lit, easy-to-read LCD display with icons includes a broad range of language options including English, Spanish, French, Italian, Portuguese, German, Russian and Chinese to meet global requirements.

Ordering Information

The XNX part numbering system contains all necessary information to convey the product configuration including options. Agency, Port Thread, Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or Fieldbus interfaces and factory installed local HART®. To order XNX parts, call 800-538-0363.

XNX Order Information Matrix

XNX Transmitter
Material LM25 Aluminum, painted (SS316 painted optional)
Cable Entries 5 conduits/cable entries – (2 right, 2 left, 1 bottom) Available in ¾" NPT, or M25
Termination Cage Clamp pluggable Terminal Blocks with retaining screws, 0.5 to 2.5mm (12-28 AWG)
Mounting XNX Enclosure Bracket (ears on casting for u-bolt). Integral cast mounting flanges provide secure mounting to surfaces, channels or up to 6" Pipe.
Optional Remote sensor (up to 50 ft / 15.2 M) for Cat Bead and Toxic
User interface Standard Custom Backlit LCD. 2.5" High Resolution DOT Matrix Display. Discrete Alarm and Status indication. Reliable Non-Intrusive 4 button interface magnetic wand access. Optional HART Handheld with IS Port
Signal Standard HART over 3-wire 4-20mA (sink or source). Optional Modbus over RS-485 and Foundation Fieldbus
Environmental
Temperature -40°C to +65°C / -40°F to +149°F (sensor dependent)
Humidity 20 to 90% RH non-condensing
IP Rating NEMA 4X IP65
Options
  Form C and SPDT 3 Relays, 240 VAC, 5A (2 Alarm, 1 Fault) (Mutually exclusive with Modbus and Fieldbus Options)
Power
  18V to 32V (24V nominal)
Hazardous Area Approvals
 
Performance Approvals UL Certified Class 1, Div 1
ATEX Zone 1
Display Module & User Interface (Standard)
Display Type Backlit LCD
Information Displayed
Base Information: Gas Reading
Gas Name and Units of measurement
Fault and Alarm Status
Large Numeric concentration or LEL display
Bar graph showing current reading, set points and full scale.
Fault/Alarm and Operating Status Indication: Security settings allow multi level operator access for set-up, configuration and calibration
Event history stores Time and Date of all Alarm, Diagnostic, Configuration events
Interface Magnetic wand with terminal screwdriver (supplied each unit)
4-20mA & HART (Standard Supply)
Description Fully configurable isolated 4-20mA & HART output module providing current sink, current source and isolated modes of operation. (supports HART 6.0 protocol)
Non-intrusive Interface Optional local IS port to enable HOT connection of a HART handheld configurator
Operating Modes Current sink / Current source / Isolated current sink /Conventional or with HART data
Output Range 0 to 22mA
4-20mA Signal Accuracy +/- 1% FS
Max loop resistance 600 Ohms at 24Vdc loop supply
Functions Supported via HART
Gas Reading Detailed Sensor Information Including: RTC (Excel Only)
Gas Name and Units of measurement 4-20mA signal level Optical Signal Level Calibration and Configuration status
General/Device Information Dynamic Reserve (Excel Only) Detailed Fault and Warning Information
Installation Raw reading Fault and Alarm History
Configuration Temperature
Forcing of 4-20mA output
Local IS HART Port (Optional)
Description Provides externally accessible IS connections to the XNX transmitter to enable HOT connection of HC275/375 HART or equivalent hand held configurator.
Installation Fitted to one of the cable entries on the XNX transmitter.
Environmental Protection Terminals protected by cover to IP 66 when not in use
Relay Module (Optional)
Description Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault relays. Single Pole Double Throw SPDT. Option PCB Factory installed in display module.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Rating
Maximum: 240VAC, 5A (non inductive load) Minimum: 5V, 10mA (non inductive load)
Electrical Connections Fault: Common, Normally Open, Normally Closed
Alarm 1: Common, Normally Open, Normally Closed
Alarm 2: Common, Normally Open, Normally Closed
Configuration
Default Configurable Options
Fault Relay: Fault Relay:
Normally energized Normally energized / normally de-energized
Non latching None
Signal inhibit as fault Enable/disable
Alarm 1 / 2 Relays: A1 / A2 Relays:
Normally de-energized Normally energized / de-energized
Non latching Latching / non latching
Alarm rising on gas reading Alarm on rising / falling
Alarm level 20% and 40% of scale Alarm level 10% to 90% of full scale
Hysteresis of 2% of scale
Re-setting of Latched Relays Easily accessible interface on display (if used) or via HART interface (local or remote)
Note Use of the Relay Module or 'Other' Communications Module (E.g. Foundation Fieldbus) is mutually exclusive. However, relay function may be used in conjunction with standard communication output i.e. 4-20mA with HART.
Relay Specific Functions via HART Interface Relay status information / Reset of latched conditions / Configuration of relays Forcing of relay state
Reset through non intrusive User Interface. Remote Switch closure using Remote Reset input Remotely through HART
Foundation Fieldbus Module (Optional)
Description Foundation Fieldbus compliant digital communications interface enables connection of the XNX transmitter to a multi-drop Foundation Fieldbus H1 network.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections Sig+, Sig- and Screen
Physical Layer Conforms to IEC 1158-2 and ISA 50.02, 31.25Kbits/s
Maximum No. of Nodes 32
Functions Supported
Gas Reading Detailed Sensor Information Including: Detailed Fault and Warning Information:
Gas Name and Units of measurement Optical Signal Level Fault and Alarm History
Instrument status (OK, warning, fault, over-range) Dynamic Reserve (Excel Only) Zero Calibration
Remote zero and span calibration (detector dependent) 24V supply voltage
Remote zero and span calibration (detector dependent) Temperature
  RTC (Excel Only)
  Calibration and Configuration status
Modbus RTU Module (Optional)
Description The Modbus output module provides an Isolated RS485 output to enable the connection of the XNX transmitter to a multi-drop Modbus network
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections RS485+, RS485-, Drain
Physical Layer Isolated RS485, 1200 to 19.2K Baud
Maximum No. of Nodes 254 XNX compatible transmitters only
Protocol Modbus RTU
Functions Supported As per Foundation Fieldbus Module (Optional) - see above
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > HONEYWELL XNX AND SERIES 3000
    XNXXSN1SS Replacement Sensor Assembly for Nitrogen Dioxide (NO2) XNX Transmitter. 0-10.0ppm, user adjustable (5.0 to 50.0ppm, 5.0ppm increments) ..

  • ACCESSORIES > HONEYWELL XNX
    02000-A-1635 Honeywell Weatherproof cap for use with Toxic/Oxygen detector including remote gassing nozzle (for Toxic Sensepoint Zareba and Sieger, Signalpoint, Satellite -with adapter-, XNX MPD, Series 2000 and 705 sensors) ..

  • ACCESSORIES > HONEYWELL XNX
    1226A0354 Remote Gassing Kit for XNX transmitters ..

  • ACCESSORIES > HONEYWELL XNX
    S3KRMK Remote Electrochemical EC sensor mounting kit for Honeywell XNX transmitters. ..

  • ACCESSORIES > HONEYWELL XNX
    SPXCDWP Enclosed weather protection housing with bump port for Honeywell XNX. ..

  • CALIBRATION GAS > NITROGEN DIOXIDE
    CYL-10474525 Calibration Gas Nitrogen Dioxide (NO2) 10 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • CALIBRATION GAS > NITROGEN DIOXIDE
    CYL-10474553 Calibration Gas Nitrogen Dioxide (NO2) 50 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • CALIBRATION GAS INDUSTRIAL SCIENTIFIC > NITROGEN DIOXIDE
    ISC-1810-2219-EQUIV Calibration Gas Nitrogen Dioxide 5ppm Balance Nitrogen 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID tag) ..

  • MULTI-POINT CONTROLLERS > 8-CHANNEL
    TPPLBDWA2NNNNNN Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, Built-in sounder, 3 alarm relay outputs, data ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NITROGEN DIOXIDE :    28 Items found.
PPS+-NO2
(6814)

PROSENSE  PPS+-NO2

Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



$261.00 
M001-0011-000
(6004)

MPOWER  M001-0011-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitrogen Dioxide (NO2) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$268.20 
TX1-4
(5967)

INDUSTRIAL SCIENTIFIC  TX1-4

Industrial Scientific Tango TX1 Gas Detector for Nitrogen Dioxide (NO2) 1-150 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

PC3-6824
(6809)

PROSENSE  PC3-6824

Prosense PC3-6824 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$396.00 
BWS_-D-Y
(6391)

BW  BWS-D-Y

BW Solo Serviceable Single-gas Detector for Nitrogen dioxide (NO2) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

10154078
(4445)

MSA  10154078

MSA ALTAIR 2X Portable Single Gas Detector with XCell Sensor Technology for Nitrogen Dioxide (NO2) Range 0-50 ppm. Low Alarm 2.5ppm, High Alarm 5ppm. Polycarbonate Housing. 25 feet drop test. 95dB audible alarm. Monochrome LCD Display. IP67. cCSAus, ATEX and IEC Approved.

Configure

$522.00 
G02-B510-100
(3020)

RAE  G02-B510-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Nitrogen Dioxide (NO2) 0-20 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

6302-0041
(6235)

BACHARACH  6302-0041

Bacharach MGS-410 Gas Detector Transmitter with electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$538.20 
6302-1041
(6245)

BACHARACH  6302-1041

Bacharach MGS-450 Gas Detector Transmitter with electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$603.00 
TX-6-ND
(2046)

MACURCO  TX-6-ND

Macurco TX-6-ND low voltage Gas Detector, Controller and Transducer for Nitrogen Dioxide (NO2) 0-20 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1.

Configure

$603.00 
TX-12-ND
(3417)

MACURCO  TX-12-ND

MACURCO TX-12-ND line voltage Gas Detector, controller and transducer for Nitrogen Dioxide (NO2) 0-20ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$609.75 
P-6834
(6784)

PROSENSE  P-6834

Prosense P-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$693.00 
6302-4041
(6255)

BACHARACH  6302-4041

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$740.70 
364-455-01-365-732-01
(6156)

DELPHIAN  364-455-01-365-732-01

Delphian GazTell Fixed Point Electrochemical Gas Detector for Nitrogen Dioxide (NO2) 0-100ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$768.00 
SPSTAXN1
(1924)

HONEYWELL  SPSTAXN1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Nitrogen dioxide (NO2) 0-10ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$804.52 
GG-NO2-B-10
(5982)

CALIBRATION TECHNOLOGIES  GG-NO2-B-10

CTI GG-NO2-B Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. NEMA 3RX polycarbonate housing. CSA and UL approved.

Configure

$900.90 
1100ALD-109024/007P
(6915)

RC SYSTEMS  1100ALD-109024/007P

RC Systems SenSmart 1100 gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 1 (Explosion Proof).

Configure

$914.78 
2106B1422
(1467)

HONEYWELL  2106B1422

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitrogen Dioxide (NO2) 0-10 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$921.03 
PQD-6834-1/2
(6745)

PROSENSE  PQD-6834-1/2

Prosense PQD-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,071.00 
6600-8024
(6270)

BACHARACH  6600-8024

Bacharach MGS-550 Industrial Refrigerant Gas Detector with electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. CE, UL and CSA Approvals.

Configure

$1,099.80 
Page: 1 | 2 | All