DET-TRONICS   EQ3016

SKU# (7736)
DET-TRONICS EQ3016
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Det-tronics Eagle Quantum Premier (EQP) Controller EQ3016 for fire and gas system communication and control. LON/SLC loop. Supports up to 246 field devices. RS-485 MODBUS RTU, Ethernet MODBUS TCP/IP and Allen Bradley ControlNet protocols. 24 VDC. FM, CSA, ATEX, CE, IECEx and SIL 2 approvals.

Please Email us your request for quote   

   4 Weeks  ]

The Eagle Quantum Premier Controller is a microprocessor based module that performs all the communication and control functions for the fire and gas system. The controller is approved as an annunciation and releasing device for fire alarm systems.

The Local Operating Network/Signaling Line Circuit (LON/SLC), through which all field devices communicate, starts and ends its loop at the Controller. The Controller continuously monitors the field devices on the LON/SLC and performs the logic functions needed to generate the appropriate output(s).

The Controller performs both static and user programmable logic operations. Static logic activates built-in annunciation circuits, consisting of both visible and audible alarms, per ANSI NFPA 72.

Programmable logic allows the Controller to be customized to perform a variety of complex logic operations. Using Det-Tronics Safety System Software (S³), the Controller can be programmed to implement any cross-zone monitoring, voting, or timed operations that might be needed in a fire suppression system.

FEATURES
  • Approved annunciation and releasing device per NFPA 72
  • Meets FM/CSA guidelines as an approved gas system
  • SIL 2 capable model available
  • Redundant controller capability
  • Programmable logic
  • Uses RS-485 MODBUS RTU, Ethernet MODBUS TCP/IP, and Allen Bradley ControlNet protocols
  • Four-line, 20 character alphanumeric display
  • LED status indicators
  • Fault tolerant communication loop
  • Extensive built-in diagnostics
  • Supports up to 246 field devices
  • FM/CSA/ATEX/CE/IECEx
  • Model available with US Coast Guard type approval under 46 CFR 161.002
REDUNDANCY

Two EQP controllers can be configured as a redundant pair, thereby increasing the availability of the system. The controllers work in "Master" and "Hot Standby" mode. Under normal operating conditions, the Standby controller receives the same inputs and update information as the Master, but has no control over the outputs and does not execute user logic. In the event of a switchover, a bumpless transfer occurs. Controller redundancy offers the following features:

  • Automatic configuration of the standby controller
  • Bumpless transfer
  • Forced and automatic switchover
  • No downtime on controller replacement
  • Automatic synchronization between controllers
  • Increased system availability

Specifications
Input Voltage 24 Vdc nominal, 18 to 30 Vdc. 10% overvoltage will not cause damage to the equipment.
Input Power 9 watts nominal, 12 watts maximum.
I/O Ports The Controller provides two electrically isolated serial ports, which can be active simultaneously. Port 1 is a RS-232 port used for system configuration. Port 2 is a RS-485 port that supports MODBUS RTU protocol.
An optional dual media ControlNet board is available. This provides a ControlNet interface, which enables users to monitor status information as well as configure various controller parameters.
Optional Interface Boards

The EQP Controller supports either one Ethernet Board or one Serial Board.

Ethernet Interface Board

The optional Ethernet board supports one additional serial port and two Ethernet ports. Ethernet supports 10/100 Mbs communication. For a redundant controller configuration, the board is required in both controllers.

Serial Interface Board

The optional serial board supports up to three additional serial ports. For a redundant controller configuration, the board is required in both controllers.

Unsupervised Outputs (8 Relays) Dry Contact Rating: 1 ampere at 30 Vdc maximum. SPDT normally open/normally closed contact, configurable for normally energized or de-energized (de-energized is the default mode).
Trouble Output SPDT normally open/normally closed contact. Non-configurable, normally energized only.
Relay Response Time Output relays actuate in < 0.1 second after acknowledging an alarm command message.
Unsupervised Digital Inputs (8 Channels) Two state input (on/off). User selectable normally open or normally closed contact (N.O. is the default).
Temperature Range Operating: Refer to Certification section in EQP manual (95-8533).
Storage: -40°C to +85°C (-40°F to +185°F). Excluding communication port optional modules.
Humidity Range 5 to 95% RH, non-condensing.
Mounting DIN rail or panel mount specified at the time of order.
Vibration FM 3260, FM 6310/6320
CERTIFICATION FM/CSA: Class I, Div. 2, Groups A, B, C, D (T4). Class I, Zone 2, Group II (T4). Tamb = -40°C to +80°C. Performance verified.
ATEX/CE: ATEX/EMC Directive Compliant 3 G. Ex nC IIC T4 Gc. EN 60079-29-1 & EN 60079-29-4. DEMKO 02 ATEX 133867X. Tamb = -40°C to +80°C. Tamb = -40°C to +70°C.
IECEx: IECEx ULD 10.0004X. Ex nC IIC T4 Gc. Tamb = -40°C to +80°C. Tamb = -40°C to +70°C.
Applicable only if relays 1-7 (terminals 21-41) are configured such that the relay contacts are normally open and de-energized.
SIL: IEC 61508 Certified SIL 2 Capable
Applied to specific models
Refer to the EQP Safety manual (95-8599).
Shipping Weight (Approximate) 5.0 lbs. (2.3 kg).
Dimensions See Figure 2 (Controller with Ethernet option shown).
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100045

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> DET-TRONICS :    30 Items found.
006097-002
(7431)

DET-TRONICS  006097-002

Det-tronics 006097-002 Green Laser Aimer for use with the Q1201A and Q1201C Laser Holder in sighting and testing the area offlame detection coverage.



 
(7253)

DET-TRONICS  009208-002

Det-tronics 009208-002 oi Replacement Kit for X5200/X9800/X2200. Includes five (5) plates and a W6300B1003. Black Plastic Material.



 
005434-004
(7255)

DET-TRONICS  005434-004

Det-tronics 005434-004 Electrochemical Sensor Cell for Hydrogen Sulfide (H2S) 0-50ppm for use with Model C7064E housings.

010274-003
(7257)

DET-TRONICS  010274-003

Det-tronics GT3000 Certified Calibration Kit for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm. Includes sturdy carrying case containing two cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 1 liter/minute regulator and pressure indicator, 3-foot tube and GT3000 Calibration Cup.

010569-001
(7247)

DET-TRONICS  010569-001

Det-tronics 010569-001 UD10 Display Module. Relay / 4-20 mA Output.



 
(7434)

DET-TRONICS  012287-002

Det-tronics 012287-002 LS2000 Alignment Tool



 
UD10S5N28W2
(7262)

DET-TRONICS  UD10S5N28W2

Det-tronics FlexVu UD10 Explosion-Proof Universal LCD Backlit Display Unit. 24 VDC. Includes 4-20 mA output with HART, relay contacts, and Modbus RS485. Eventm fault and alarm logs. FM, CSA, ATEX, IECEx and SIL 2 certified for Class I Div 1 ... more

010970-004
(7248)

DET-TRONICS  010970-004

Det-tronics 010970-004 UPGRADE KIT UD10S5N25T2. Allows field conversion of a Digital Communication Unit (DCU) to a FlexVu UD10 Universal Display. Adds relay, 4-20 mA, RS485 and HART outputs. FM, CSA, ATEX, IECEx and SIL 2 Approvals.



 
009174-013
(7430)

DET-TRONICS  009174-013

Det-tronics 009174-013 EQ3730 8 Channel Enhanced Discrete Input/Output Module (EDIO) with DIN Rail mounting. FM, CSA, ATEX, IECEx and SIL 2 approvals.



 
EQ3001PCSW-C
(7433)

DET-TRONICS  EQ3001PCSW-C

Det-tronics EQ3001 Eagle Quantum Premier Controller for up to 246 Nodes. Includes 3 RS-232, 2 RS-485 ports and 8 Programmable Relay Outputs. Modbus RTU, Modbus TCP/IP or Allen Bradley protocols. FM, IEC, SIL 2 approvals.



 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.