Det-tronics Ud10s5n28w2 | Det-tronics | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DET-TRONICS   UD10S5N28W2

SKU# (7262)



DET-TRONICS UD10S5N28W2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Det-tronics FlexVu UD10 Explosion-Proof Universal LCD Backlit Display Unit. 24 VDC. Includes 4–20 mA output with HART, relay contacts, and Modbus RS485. Eventm fault and alarm logs. FM, CSA, ATEX, IECEx and SIL 2 certified for Class I Div 1 and Div 2, Zone 1 and Zone 2.

UD10S5N28W2   
Please Email us your request for quote   

Material
Threads
Model

   18 Weeks  ]
8 Variants of base SKU
DESCRIPTION

The FlexVu ® Model UD10 is recommended for applications that require a gas detector with digital readout of detected gas levels as well as analog 4–20 mA output with HART, relay contacts, and Modbus RS485. The UD10 is designed for use with Det‑Tronics gas detectors such as GT3000, PIR9400, PIRECL, PIRECL CO 2 , C706x*, CTX10/CGS, CGS**, ATX10/AV10, PIRDUCT, or LS2000, as well as generic linear 4–20 mA sensors. The display unit is designed and approved as a “stand alone” device and performs all the functions of a gas controller.

Gas concentration and unit of measurement are indicated on a digital display. The display unit provides a linear isolated/non-isolated 4–20 mA DC output signal (with HART) that corresponds to the detected gas concentration.

All electronics are enclosed in an explosion-proof aluminum or stainless steel housing. The display unit is used with a single detector that may be either coupled directly to the UD10, or remotely located using a sensor termination box. The UD10 features non-intrusive calibration. A magnet is used to perform calibration as well as to navigate the UD10’s internal menu.

The UD10 can be used with various 4–20 mA gas detection devices, with or without HART. The unit provides display, output, and control capabilities for the gas detector.

The UD10 utilizes the following I/O:

  • Signal Inputs: 4–20 mA loop from the sensing device
  • User Inputs: Magnetic switches (4) on the display panel HART communication
  • Signal Outputs: 4–20 mA output loop with HART, Modbus RS485, Three alarm relays and one fault relay
  • Visible Outputs: Backlit LCD display, ART slave interface via HART Communicator
FEATURES AND BENEFITS
  • Universal design supports multiple Det-Tronics sensors or generic linear 4–20 mA sensors
  • Local digital LCD display continuously indicates gas level, gas type, and units measured
  • Backlit and heated display
  • Non-intrusive calibration quickly performed by one person
  • Rugged construction approved for use in classified hazardous areas
  • Linear isolated/non-isolated 4–20 mA output with HART
  • Non-intrusive menu allows device configuration without de‑classifying the hazardous area
  • Internal magnetic switches provide a non‑intrusive user interface
  • Smart capabilities with access to sensor information and measurement range
  • Event logs: Calibration with date and time stamp
  • Fault logs: Detector fault, Low power, and General fault
  • Alarm logs: High gas alarm, Low gas alarm, and Aux alarm
  • SIL2 models certified to IEC61508 by exida ®

SPECIFICATIONS
Operating Voltage 24 Vdc nominal, operating range is 18 to 30 Vdc.
Operating Power Standard model, with heater and backlight off:
No alarm: 1.5 watts @ 24 Vdc.
Alarm: 3 watts @ 24 Vdc (20 mA current output and all 3 alarm relays energized).
Backlight on: 0.5 watt additional.
Heater on: 3.5 watts additional.
CGS model: Add 4 watts with CGS interface board and CGS sensor installed.
Maximum power in alarm, with heater and backlight on:
7 watts @ 30 Vdc (Standard model)
11 watts @ 30 Vdc (CGS model)
NOTES:
– Heater turns on when the internal temperature drops below –10°C. Heater function can be disabled to save power.
– Appropriate relays will be activated when a fault or alarm occurs.
Current Output Linear isolated 4–20 mA output with HART.
Maximum loop resistance 600 ohms at 18 to 30 Vdc.
Relay Contacts Three Alarm Relays:
Form C, 5 amperes at 30 Vdc.
Selectable energized/de-energized.
Selectable latching/non‑latching.
One Fault Relay:
Form C, 5 amperes at 30 Vdc.
Normally energized for no fault condition with power FM applied.
Operating Temperature –55°C to +75°C.
Storage Temperature –55°C to +75°C.
Humidity Range 5 to 95% RH (Det-Tronics verified).
Wiring Terminals 14 to 18 AWG, 2.5-0.75 mm 2 wire can be used.
Conduit Entries 3/4" NPT or M25.
Enclosure Material Epoxy coated aluminum or 316 stainless steel.
Shipping Weight Aluminum: 4.15 pounds (1.88 kilograms).
Stainless Steel: 10.5 pounds (4.76 kilograms).
Warranty Find warranty information by clicking on the Terms and Conditions section of the Det-Tronics Resources page: https://www.det-tronics.com/resourcetypes
Electro-Magnetic Compatibility EMC Directive 2014/30/EUM
EN 50270:2015M
EN 61000-6-2:2005M
EN 61000-6-4:2007
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531200020

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> DET-TRONICS :    16 Items found.
005434-004
(7255)

DET-TRONICS  005434-004

Det-tronics 005434-004 Electrochemical Sensor Cell for Hydrogen Sulfide (H2S) 0-50ppm for use with Model C7064E housings.

010569-001
(7247)

DET-TRONICS  010569-001

Det-tronics 010569-001 UD10 Display Module. Relay / 4-20 mA Output.



 
010970-004
(7248)

DET-TRONICS  010970-004

Det-tronics 010970-004 UPGRADE KIT UD10S5N25T2. Allows field conversion of a Digital Communication Unit (DCU) to a FlexVu UD10 Universal Display. Adds relay, 4-20 mA, RS485 and HART outputs. FM, CSA, ATEX, IECEx and SIL 2 Approvals.



 
Q9033B1000
(7252)

DET-TRONICS  Q9033B1000

Det-tronics Q9033B Stainless steel Mounting Arm for all X-Series flame detectors (DNV approved with X3301).



 
101197-004
(7246)

DET-TRONICS  101197-004

Det-tronics 101197-004 Type A Stop Plug, 3/4" NPT. Stainless Steel. Hex Size 12. 14.8mm.



 
(7254)

DET-TRONICS  107427-040

Det-tronics 107427-040 O-ring Rear Cover (Viton) for X-Series flame detectors.



 
006824-001
(7256)

DET-TRONICS  006824-001

Det-tronics CGS Combustible Gas Sensor for UD10, UD30, DCUEX, U9500A, U8700, K-Series, 400, 405, 505, 500, 810, 820, and 880 Transmitters. Stainless steel catalytic sensor with %LEL range. FM, CSA, ATEX, IECEx and SIL 2 Approvals.

010274-003
(7257)

DET-TRONICS  010274-003

Det-tronics GT3000 Certified Calibration Kit for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm. Includes sturdy carrying case containing two cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 1 liter/minute regulator and pressure indicator, 3-foot tube and GT3000 Calibration Cup.

227117-001
(7258)

DET-TRONICS  227117-001

Det-tronics GT3000 Certified Calibration Gas Kit Replacement Cylinder for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm.

006468-001
(7259)

DET-TRONICS  006468-001

Det-tronics PIRECL, PIR9400, and PIRDUCT Certified Calibration Kit for Methane 0-50% LEL, 2.5% vol. for field calibration of all PointWatch IR detectors. Kit includes Two 3.6 ft 3 (103 liters) cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 2.5 liter/minute regulator and pressure indicator, 3-foot tube and sturdy plastic carrying case.



 
(7253)

DET-TRONICS  009208-002

Det-tronics 009208-002 oi Replacement Kit for X5200/X9800/X2200. Includes five (5) plates and a W6300B1003. Black Plastic Material.



 
(7265)

DET-TRONICS  009700-001

Det-tronics 009700-001 Magnetic tool for use with FlexSonic AC100, ATX10, FlexVu UD10, FlexVu UD20 and GT3000 detectors.



 
GTSH2S+100PSES
(7251)

DET-TRONICS  GTSH2S+100PSES

Det-tronics GTS Toxic Gas Sensor Module for GT3000 Series Detectors for Hydrogen Sulfide (H2S) 0-100 PPM.



 
GTXSN26N5
(7249)

DET-TRONICS  GTXSN26N5

Det-tronics GTX Electrochemical Toxic Gas Transmitter for GT3000 Series Detectors. Two-wire loop powered. 12-30 VDC. 4-20 mAoutput signal with HART. Explosion proof. IP66. FM/CSA and IECEx approved. Suitable for Class I Div 1, Div 2 and Zone 1.

009640-001
(7261)

DET-TRONICS  009640-001

Det-tronics 009640-001 GTS Replacement Filter for GT3000 Series Detectors.



 
(7264)

DET-TRONICS  004532-002

Det-tronics 004532-002 Hydrophobic Replacement Filter for U8800 Controller



 
Cookie Notice