Honeywell FireLite Alarms MDF-300 Dual Monitor Module for monitoring NO contact fire alarm and supervisory devices. 15 to 32 VDC. Two 2-wire IDC. FM and UL approvals.

MDF-300
$0.96      

   In Stock  ]
  • Built-in type identification automatically identifies this device as two monitor modules to the control panel.
  • Powered directly by the two-wire SLC loop. No additional power required.
  • High noise (EMF/RFI) immunity.
  • SEMS screws with clamping plates for ease of wiring.
  • Direct-dial entry of address 01 – 159 on the MS-9600.
  • LED flashes green during normal operation and latches on steady red to indicate alarm.

The MDF-300 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independant two-wire fault-tolerant Initiating Device Circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed security devices. The module has a single panel-controlled red LED indicator.

MDF-300 Applications

Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normallyopen supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms.

MDF-300 Operation

Each MDF-300 uses two of 99 (MS-9200) or 159 (MS-9600) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop).

INSTALLATION

MDF-300 module mount directly to a standard 4" (101.6 mm) square, 2.125" (53.975 mm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only.

Specifications
Normal Operating Voltage: 15 to 32 VDC
Maximum Current Draw: 6.4 mA (LED on)
Average Operating Current: 750µA (LED flashing)
EOL Resistance: 47K Ohms
Maximum SLC Wiring Resistance: 40 Ohms
Maximum IDC wiring resistance: 1,500 Ohms
Maximum IDC Voltage: 11 Volts
Maximum IDC Current: 240µA
Temperature Range: 32˚F to 120˚F (0˚C to 49˚C)
Humidity: 10% to 93% Non-condensing
Dimensions: 41/2 in H × 4.275 in W × 1.4 in D (Mounts to a 4 in square by 21/8 in deep box.)
Accessories: SMB500 Electrical Box

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.