Det-tronics CGS Catalytic Combustible Gas Sensor for UD10, UD30, DCUEX, U9500A, U8700, K-Series, 400, 405, 505, 500, 810, 820, and 880 Transmitters. Stainless steel catalytic sensor with %LEL range. FM, CSA, ATEX, IECEx, Brazilian and SIL 2 Approvals.

006824-001   
Please Email us your request for quote   

Model

   8 Weeks  ]
3 Variants of base SKU
DESCRIPTION

The Det-Tronics family of catalytic combustible gas sensors provide unmatched flammable gas detection performance in harsh environments and challenging conditions.

The heart of the catalytic sensor consists of a pair of computer matched pellistors (beads) that provide identical electrical resistance in clean air. When flammable gas is present, the active bead catalyzes the combustible gas molecules, while the inactive (reference) bead balances the reaction and compensates for normal changes in the ambient environment. The sophisticated design and construction of Det-Tronics catalytic sensors provides excellent sensitivity, response time, and resistance to physical shock and vibration.

All Det-Tronics catalytic gas sensors are poison-resistant, and are constructed with a one-piece 316 stainless steel housing. Other features include an integral thermal barrier to prevent bead interaction, and a sinter bonding technique to ensure superior protection against electromagnetic interference. All sensors are provided with a laser etched identification and approvals label that will withstand exposure to harsh outdoor industrial environments.

The CGS can be used for detection of virtually all combustible and flammable gases, including hydrogen, and is compatible with the FlexVu ® UD10, Infiniti® U9500, Model 505 transmitter, EQ22xxDCUEX, and STB.

FEATURES AND BENEFITS
  • One piece design with integral thermal barrier
  • Sinter bonded flame arrestor provides superior EMI protection
  • 316 stainless steel housing
  • Excellent impact and vibration resistance
  • Standard poison-resistant performance rating
  • FM/CSA/ATEX/IECEx/Brazilian Approvals
  • Compatible with all Det-Tronics combustible gas transmitters and controllers
  • Sensor Separation Termination Box (STB) options available
  • Extended operating temperature range
  • Comprehensive list of conversion K factors for proper calibration available
  • 3/4 inch NPT, 20 mm, or 25 mm thread types
  • Six inch or optional 30 inch wire lead lengths
  • Constant voltage or constant current sensor types available
  • SIL2 certified to IEC6

SPECIFICATIONS
Temperature Range Operating: –67°F to +257°F (–55°C to +125°C).
Performance: –40°F to +167°F (–40°C to +75°C).
Humidity Range 0 to 99% RH, non-condensing.
Response Time T50, s: <10
T90, s: <30
Verification: FM, CSA, ATEX
Recovery Time < 30 seconds after exposure to pure methane.
Accuracy / Linearity ±3% LFL from 0 to 50% LFL,
±5% LFL from 51% to 100% LFL.
Wiring 2x22 AWG, 1x16 AWG, 600V, 20"
Repeatability ±1% LFL.
Long Term Stability Zero: < 1% LFL per month.
Span: < 1% LFL per month in clean air.
Temperature Stability < ±5% LFL: –13°F to +167°F (–25°C to +75°C).
< ±10% LFL: –40°F to –13°F (–40°C to –25°C).
Sensor Life 3 to 5 years, when environment is free of substances and conditions known to be detrimental to catalytic sensing elements.
Storage Life Indefinite, when stored in unopened original packaging.
Calibration Cycle 30 days after initial calibration and every 90 days thereafter, or as required by the application and environment.
RFI/EMI Immunity Refer to selected transmitter specification.
Dimensions 1.5in (3.8cm) x 1.7in (4.4cm) x 2.0in (5.2cm)
Thread options • 3/4” NPT
• M20
• M25.
Certification FM/CSA:
Class I, Div. 1, Groups B, C, & D
Tamb = –40°C to +75°C
Explosion-proof verified:
–40°F to +257°F (–40°C to +125°C)
Performance verified:
–40°F to +167°F (–40°C to +75°C)
Complies with ANSI/ISA-12.13.01-2000.
ATEX:
CE 0539
II 2 G
Ex db IIC T3/T5
DEMKO 02 ATEX 131323X
T5 (Tamb = –40°C to +75°C)
T3 (Tamb = –55°C to +125°C)
IECEx:
Ex db IIC T3/T5
IECEx ULD 10.0001X
T5 (Tamb = –40°C to +75°C)
T3 (Tamb = –55°C to +125°C)
EN/IEC Standards:
EN/IEC 60079-0: 2012/2011
EN/IEC 60079-1: 2014
EN 60079-29-1: 2007
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027905910

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> DET-TRONICS :    26 Items found.
(7254)

DET-TRONICS  107427-040

Det-tronics 107427-040 O-ring Rear Cover (Viton) for X-Series flame detectors.



 
(7438)

DET-TRONICS  104190-002

Det-tronics 104190-002 Aluminum Stop Plug. 3/4NPT. INMETRO approval.



 
101197-004
(7246)

DET-TRONICS  101197-004

Det-tronics 101197-004 Type A Stop Plug, 3/4" NPT. Stainless Steel. Hex Size 12. 14.8mm.



 
(7437)

DET-TRONICS  102740-002

Det-tronics 102740-002 Calibration Magnet for X-Series flame detectors and PIRECL, U5015 and LS2000 gas detectors.



 
(7265)

DET-TRONICS  009700-001

Det-tronics 009700-001 Magnetic tool for use with FlexSonic AC100, ATX10, FlexVu UD10, FlexVu UD20 and GT3000 detectors.



 
009640-001
(7261)

DET-TRONICS  009640-001

Det-tronics 009640-001 GTS Replacement Filter for GT3000 Series Detectors.



 
(7264)

DET-TRONICS  004532-002

Det-tronics 004532-002 Hydrophobic Replacement Filter for U8800 Controller



 
Q9033B1000
(7252)

DET-TRONICS  Q9033B1000

Det-tronics Q9033B Stainless steel Mounting Arm for all X-Series flame detectors (DNV approved with X3301).



 
007338-001
(7432)

DET-TRONICS  007338-001

Det-tronics 007338-001 Q2000 X-Series Weather Shield. Epoxy coated aluminum.



 
227117-001
(7258)

DET-TRONICS  227117-001

Det-tronics GT3000 Certified Calibration Gas Kit Replacement Cylinder for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm.

GTXSN26N5
(7249)

DET-TRONICS  GTXSN26N5

Det-tronics GTX Electrochemical Toxic Gas Transmitter for GT3000 Series Detectors. Two-wire loop powered. 12-30 VDC. 4-20 mAoutput signal with HART. Explosion proof. IP66. FM/CSA and IECEx approved. Suitable for Class I Div 1, Div 2 and Zone 1.

STB7S5NB
(7439)

DET-TRONICS  STB7S5NB

Det-tronics STB Series Sensor Termination Box / Separation Kit includes junction box, proper connector board for GT3000, NTMOS, and C706x series detectors, or any 4-20 mA device.



 
GTSH2S+100PSES
(7251)

DET-TRONICS  GTSH2S+100PSES

Det-tronics GTS Toxic Gas Sensor Module for GT3000 Series Detectors for Hydrogen Sulfide (H2S) 0-100 PPM.



 
CTX10S3F2T
(7435)

DET-TRONICS  CTX10S3F2T

Det-tronics CTX Catalytic Combustible Gas Transmitter. 4-20 mA output signal. Stainless Steel enclosure. M20 threads. FM, CSA, ATEX, IECEx and SIL approvals.



 
007525-005
(7429)

DET-TRONICS  007525-005

Det-tronics 007525-005 Horizontal Direct Duct Mounting Kit for PointWatch Eclipse Model PIRECL. FM approved.



 
006468-001
(7259)

DET-TRONICS  006468-001

Det-tronics PIRECL, PIR9400, and PIRDUCT Certified Calibration Kit for Methane 0-50% LEL, 2.5% vol. for field calibration of all PointWatch IR detectors. Kit includes Two 3.6 ft 3 (103 liters) cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 2.5 liter/minute regulator and pressure indicator, 3-foot tube and sturdy plastic carrying case.



 
006097-002
(7431)

DET-TRONICS  006097-002

Det-tronics 006097-002 Green Laser Aimer for use with the Q1201A and Q1201C Laser Holder in sighting and testing the area offlame detection coverage.



 
(7253)

DET-TRONICS  009208-002

Det-tronics 009208-002 oi Replacement Kit for X5200/X9800/X2200. Includes five (5) plates and a W6300B1003. Black Plastic Material.



 
005434-004
(7255)

DET-TRONICS  005434-004

Det-tronics 005434-004 Electrochemical Sensor Cell for Hydrogen Sulfide (H2S) 0-50ppm for use with Model C7064E housings.

010274-003
(7257)

DET-TRONICS  010274-003

Det-tronics GT3000 Certified Calibration Kit for Hydrogen Sulfide (H2S) 0-10 to 0-50ppm. Includes sturdy carrying case containing two cylinders of Class 2.2 non-flammable, non-toxic compressed gas, a 1 liter/minute regulator and pressure indicator, 3-foot tube and GT3000 Calibration Cup.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.