Det-tronics 006300-012 | Lel Infrared | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DET-TRONICS   006300-012

SKU# (7250)
DET-TRONICS 006300-012
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Det-tronics PIR9400 PointWatch Infrared Hydrocarbon Gas Detector for Methane 0-100% LEL. Diffusion based. 18-30 VDC. 4-20 mA output signal. Explosion proof. IP66. Suitable for Class I Div 1, Div 2, Zone 1 and Zone 2 hazardous areas.

4-20 mA   DIV 1   DIV 2   ZONE 1   ZONE 2

Please Email us your request for quote   

   6 Weeks  ]
DESCRIPTION

The PointWatch TM detector is a diffusion-based point-type infrared gas detector approved to provide continuous monitoring of methane gas concentrations in the range of 0 to 100% LFL. The detector provides a 4-20 mA output signal, corresponding to the detected gas concentration. The detector has Division and Zone explosion proof ratings and is suitable for use in indoor and outdoor applications.

PointWatch is ideally suited for use in harsh environments and where the cost of required maintenance for conventional catalytic detectors is prohibitive. The PointWatch IR detector will perform reliably in the presence of silicone and other catalytic poisoning agents and can also operate in oxygen free environments or where high background gas levels are present. There are no known poisons that affect this technology.

The PointWatch detector is globally certified for use in Class 1, Divisions 1 and 2, and Zones 1 and 2 hazardous areas. It is also approved as a stand alone gas detector, and complies with global approvals when connected to a stand-alone approved controller for life safety. The approved Det-Tronics controllers are the FlexVu ® UD10, FlexVu ® UD30, Infiniti ® U9500, R8471, and Eagle Quantum Premier ® (EQP).

HIGHLIGHTS
  • Compliance to ANSI/ISA 12.13.01-2000 performance standard.
  • Requires no routine calibration to ensure proper operation.
  • Fail-safe operation.
  • Continuous self-test automatically indicates a fault or fouled optics condition.
  • Unique multi-layered filtering system protects optics from dirt and water ingress.
  • Internal heating system minimizes condensation, allowing reliable operation through temperature extremes.
  • There are no known poisons, e.g. silicones or hydrides, that compromise the integrity of the measurement.
  • Performs well in the presence of high concentrations or constant background levels of hydrocarbons, and in oxygen depleted atmospheres.
  • Standard 4–20 mA output (current source).
  • 0-2.4 mA indicates a calibration or fault condition.
  • Compact, lightweight, explosion-proof housing is designed for duty in harsh environments.
  • Standard 0 to 100% LFL detection range.

SPECIFICATIONS
Input Voltage 24 Vdc nominal. Operating range is 18 to 30 Vdc.
Power Consumption (Watts) Input Voltage: 18 Vdc 24 Vdc 30 Vdc
Nominal 3.5 4.6 6.2
Maximum 4.0 5.5 7.0
Detection Range 0 to 100% LFL.
Gases The Model PIR9400 Detector is approved to Methane, but most flammable hydrocarbon vapors (ethane, ethylene, propane, butane, and propylene) are also detectable.
Current Output Linear 0 to 20 mA current source
4 to 20 mA output indicates 0 to 100% LFL detection range (for linearized gases)
23.2 mA indicates over-range condition
0 to 2.4 mA levels indicate calibration, fault and fouled optics conditions.
Accuracy (Room Temperature) ±3% LFL from 0 to 50% LFL, ±5% LFL from 51% to 100% LFL.
Response Time (seconds) Multilayered aluminum weather baffle With hydrophobic screen Without hydrophobic screen: T50: 7.0 T90: 14.4
Multilayered aluminum weather baffle Without hydrophobic screen Without hydrophobic screen: T50: 5.0 T90: 10.0
Polyphthalamide (PPA) weather baffle With hydrophobic screen Without hydrophobic screen: T50: 6.0 T90: 16.0
Polyphthalamide (PPA) weather baffle Without hydrophobic screen Without hydrophobic screen: T50: 2.0 T90: 3.0
Stability (Temp) Zero: ±2% LFL from –40°C to +75°C (–40°F to +167°F).
Span: ±5% LFL at 50% LFL from –25°C to +75°C (–13°F to +167°F).
±10% LFL at 50% LFL from –40°C to –25°C (–40°F to –13°F).
Stability (Time) (10 months) ±2% LFL (Det-Tronics verified).
Repeatability (Room Temperature) Zero: ±1% LFL.
Span: ±2% LFL at 50% LFL (Det-Tronics verified).
Wiring Five 22 AWG wires, 20.0 inches (50.8 cm) long.
Temperature Range Operating: –40°C to +75°C (–40°F to +167°F).
Storage: –67°C to +85°C (–55°F to +185°F).
Humidity (non-condensing) 0 to 99% relative humidity (Det-Tronics verified) 5 to 95% relative humidity (FM/CSA verified)
RFI/EMI Protection Operates properly with 5.0 watt walkie-talkie keyed at 1 meter.
Ingress Protection IP66
Enclosure Materials Aluminum (clear anodized) enclosure and weather protection baffles. Content: 0.8% to 1.2% Mg, 0.15% to 0.40% Cu.
Stainless Steel (316 electropolished) enclosure, polyphthalamide (PPA) weather protection baffle.
Shipping Weight AL: 2.0 lbs. (0.95 kg)
SS: 4.0 lbs. (1.8 kg).
Certification FM / CSA:
Class I, Div. 1, Groups B, C & D (T5)
Class I, Div. 2, Groups A, B, C & D (T3C)
Performance per FM 6310/6320 &
CSA 22.2 #152.
ATEX:
CE 0539 II 2 G
Ex d IIB+H 2 T4-T6 Gb
DEMKO 09 ATEX 147301X
T6 (Tamb –55°C to +50°C)
T5 (Tamb –55°C to +60°C)
T4 (Tamb –55°C to +75°C)
IP66.
EN Standards:
EN 60079-0: 2009
EN 60079-1: 2007
EN 60529-1991+A1: 2000
EN 60079-29-1: 2007.
IECEx:
IECEx ULD 10.0017X
Ex d IIB+H 2 T4-T6 Gb
T6 (Tamb –55°C to +50°C)
T5 (Tamb –55°C to +60°C)
T4 (Tamb –55°C to +75°C)
IP66.
GOST–R:
GOST R Certificate of Compliance
VNIIFTRI:
Pattern Approval Certificate of Measuring
Instruments.
INMETRO:
CEPEL 97.0059X
Ex d llB+H 2 T6 Gb IP66
T6 (Tamb –55°C to +50°C)
T5 (Tamb –55°C to +60°C)
T4 (Tamb –55°C to +75°C)
Export Info
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> LEL INFRARED :    28 Items found.
012731-504
(7260)

DET-TRONICS  012731-504

Det-tronics FlexSight LS2000 Infrared gas detection system for combustible hydrocarbon gases 0-5% LEL. 4-20 mA output, HART and RS-485 Modbus communication. 24 VDC. Stainless steel transmitter and receiver. IP66/IP67. NEMA Type 4X. Suitable for Class I, Div 1 and Div 2; Class II, Div 1; Class I, Zone 1; and Zone 1, Zone 2. FM, IEC and SIL 2 Approvals.



 
116-014048-232
(7230)

AUTRONICA  116-014048-232

Autronica AutroPoint HC200 Infrared IR Hydrocarbon Gas Detector calibrated to methane, propane, ethylene, or butane 0 to 100% LEL. Explosion-proof stainless steel housing. 4-20 mA signal with HART communication. MODBUS and ASCII supported. SIL2, FM/CSA, DEMKO, IECEx and ATEX certified for use in Class I, Div 1 and Div 2, and Zone 1 and Zone 2.



 
P-3033
(6722)

PROSENSE  P-3033

Prosense P-XY35 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$797.94 
PQN-3033-1/2
(6946)

PROSENSE  PQN-3033-1/2

Prosense PQN-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$978.12 
PQD-3033-1/2
(6719)

PROSENSE  PQD-3033-1/2

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,413.89 
1300ALD-109050/100P-L0
(6904)

RC SYSTEMS  1300ALD-109050/100P-L0

RC Systems SenSmart 1300 Infrared (IR) Gas Detector for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide 0-100% LEL or %Vol with 'ST-48' smart transmitter. Infrared (IR) sensor. 3-Wire bridge. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,432.47 
100-0001-M11-SS-C1
(4722)

ESP SAFETY  100-0001-M11-SS-C1

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases, Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Div 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Configure

$1,490.40 
100-0008-SS/100-0015-C1
(4756)

ESP SAFETY  100-0008-SS/100-0015-C1

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Div 1 certification. Optional 2nd sensor available.

Configure

$1,593.90 
53001AL-0-9050/100P/L0
(7136)

RC SYSTEMS  53001AL-0-9050/100P/L0

RC Systems SenSmart 5300 3-wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with GEN2 smart sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$1,809.09 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,813.32 
967-215520-100
(2133)

DETCON  967-215520-100

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor Optional Alarm Relays, HART.

2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$2,123.32 
2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$2,123.32 
33001AL-0-9050/100P/L0
(6898)

RC SYSTEMS  33001AL-0-9050/100P/L0

RC Systems SenSmart 3300 3 wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
PIRECLA11A1BT2
(7027)

DET-TRONICS  PIRECLA11A1BT2

Det-tronics PointWatch Eclipse PIRECL Infrared Gas Detector for detection of Hydrocarbons (methane, propane, ethylene, butane) 0 to 100% LFL. Diffusion based. 4-20 mA signal with HART and RS-485 serial communication. Optional relay output. Explosion-proof and stainless steel housing. 24 Vdc. Certified for use in Class I, Div 1 and Div 2. FM, CSA, ATEX, IECEx, DNV/MED, and INMETRO certifications.

GDS-IR-1-110-0
(436)

GDS  GDS-IR-1-110-0

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Combustibles LEL (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Methane (CH4), Propane (C3H8), Isobutane (C4H10), Pentane (C5H12), Cyclopentane (C5H10), n-Butane (C4H10), Ethanol (C2H6O), Methanol (CH4O), Hexane (C6H14), Jet-A, Diesel and Gasoline.

XNXUTAVNNIF1
(1225)

HONEYWELL  XNXUTAVNNIF1

Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20 mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional Alarm Relays, Modbus, Fieldbus. *** Detector will be provided as two separate items: XNX transmitter & MPD sensor head, to be assembled by the end user ***

Configure

$2,276.97 
XNXUTAVNNIV1
(2141)

HONEYWELL  XNXUTAVNNIV1

Honeywell XNX Universal Gas Detector Transmitter including MPD-AM1V1 IR Infrared sensor combustible 0-5% Vol 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART over 4-20 mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional Alarm Relays, Modbus, Fieldbus. *** Detector will be provided as two separate items: XNX transmitter & MPD sensor head, to be assembled by the end user ***

Configure

$2,380.43 
2108N5100N
(1965)

HONEYWELL  2108N5100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane (Natural Gas), Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit), for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output.

Configure

$2,482.01 
Page: 1 | 2 | All
Cookie Notice