Honeywell S3kul2-xnxxsp1ss | Phosphine | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   S3KUL2-XNXXSP1SS

HONEYWELL S3KUL2-XNXXSP1SS
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring PHOSPHINE (PH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-1.2ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

S3KUL2-XNXXSP1SS   
1,976.66

Agency Approval/Enclosure
Splash Guard
Custom Tag

   3 Weeks  ]
6 Variants of base SKU
Honeywell Series 3000 Display
FEATURES

Reliable detection
  • Proven electrochemical sensing technology
  • Uses Surecell™ electrochemical cells, ideal for hot and humid environments
  • Long life sensing elements (typical >2 years)
  • Patented 'Reflex' sensing elemen verification diagnostics
Reduced installation costs
  • Universal mounting bracket included, supplied as standard
  • Explosion proof transmitter allows field wiring to be run along with other non IS instruments
  • Plug-in sensor removes wiring
Reduced commissioning costs
  • Sensor recognition software auto configures transmitter
  • Non-intrusive configuration
  • Plug and play factory configured sensors
Reduced maintenance costs
  • IS sensor connection permits hot swap, reducing down time
  • User programmable calibration frequency
  • Integral fault diagnostic software
  • Menu/icon driven calibration procedure
  • IP 66 rated to protect against dust/water ingress
Regulatory compliance
  • US (UL)
  • Canadian (cUL/CSA)
  • International (IECEx)
  • European (ATEX)
Range of optional accessories
  • Remote sensor mounting kit
  • Duct mounting kit (for H2, CO and H2S only)
  • Calibration cup to apply test gas
  • Collecting cone (for H2 and CO only)
Typical applications
  • Exploration and drilling platforms
  • Production platforms
  • Onshore oil and gas terminals
  • Refineries and chemical plants
  • Power plants
  • Waste water facilities
  • Utilities
Honeywell Series 3000 components

The Series 3000 MkII provides comprehensive monitoring of toxic and oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry standard 2-wire 4-20mA loop, making it ideal for both new and retrofit applications. Users can configure the detector without the need of a ‘hot work permit’ by using the LCD and magnetic switches. Fault diagnostic software and configurable calibration intervals simplify maintenance procedures.

The Intrinsically Safe smart sensors are supplied pre-configured and can be ‘hot swapped’ without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 50’ (15m) from the transmitter, making it ideal for operation in areas that are difficult to access.

Series 3000 MkII is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or support pole using the universal bracket provided. Electrical installation can be made using either conduit or cable with suitable mechanical protection. A ¾” NPT entry and M20 adapter are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions.

Detectable Gas
Gas Formula Selectable Full Default Range Default Range Operating Temperature**
Min Max
Phosphine PH3 1.2ppm only 1.2ppm -20°C / -4°F 55°C / 131°F
Series 3000 MkII Detector
Use Rugged and reliable gas detector for the protection of personnel from toxic and Oxygen gas hazards. Suitable for use in Zone 1 or 2 hazardous areas and North American Class I and II Division 1 or 2 areas.
Electrical
Connections and Power 2-wire loop powered
17VDC (+ / -10%) to 24VDC (max) operation
22mA max. over range
Signal 2-wire with screen (90% coverage) or conduit
0.5mm2 (20AWG) to 2.0mm2 (14AWG)
Connections and Power 0-100% FSD 4-20mA
Fault = 3mA
Calibration due selectable off or 3mA
Max. over range 22mA
Inhibit (toxic sensors) = Selectable 3mA or 4mA Inhibit
(Oxygen sensors) = Selectable 3mA or 17.4mA
Construction
Material Transmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel
Sensor: 316 Stainless Steel with PTFE filter
Maximum Dimensions 164mm x 201mm x 99mm
6.4" x 7.9" x 3.9"
Weight Aluminium alloy LM25: 1.7kg (3.75lbs.) Stainless Steel 316: 3.7kg (8.16lbs.)
Environmental
IP Rating IP66 (EN 60529), NEMA 4X
Certified Temperature ATEX/IECEX: -20°C to +55°C (-4°F to +131°F)
UL/c-UL: -40°C to +55°C (-40°F to +131°F)
Operating Humidity Continuous 20-90% RH (non-condensing)
Intermittent 0-99% RH (non-condensing)
Operating Pressure 90-110kPa
Storage Conditions 15°C to 30°C (59°F to 86°F) 30-70% RH (non-condensing)
Certification UL/c-UL Class I, Div 1 & 2, Groups B, C & D; Class II, Div 1, Groups E, F, G; Class II, Div 2, Groups F & G, Class I Zone 1, Group 2B + H2 Hazardous Locations
ATEX: II 2 (1) G Ex d [ia] IIB+H2 T4 (Tamb -20°C to +55°C / -4°F to 131°F)
IECEx Ex d [ia] IIB + H2 T4
Approvals CE compliant in accordance with:
ATEX Directive 94/9/EC
EMC Directive 2004/108/EC
EN 50270
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
S3KCAL
(715)

HONEYWELL  S3KCAL

Calibration cup (flow adaptor) for Honeywell Series 3000 transmitters. (for use with XNX EC sensors)



$117.16 
(261)

GDS  10-0263

GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent



 
ISC-1810-7797-EQUIV
(2597)

PORTAGAS  ISC-1810-7797-EQUIV

Calibration Gas Phosphine 5ppm Balance Nitrogen 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID tag)

Configure

$315.53 
ISC-1810-4059-EQUIV
(2595)

PORTAGAS  ISC-1810-4059-EQUIV

Calibration Gas Phosphine 1ppm Balance Nitrogen 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID tag)

Configure

$315.53 
S3KRMK
(716)

HONEYWELL  S3KRMK

Remote sensor mounting kit for Honeywell Series 3000 transmitters.

Configure

$700.84 
S3KP1SS
(713)

HONEYWELL  S3KP1SS

Replacement Sensor Cartridge for Phosphine (PH3) S3000 transmitter 0-1.2ppm



$774.49 
> PHOSPHINE :    9 Items found.
M001-0016-000
(6007)

MPOWER  M001-0016-000

mPower UNI MP100 Portable Single Gas Detector for detection of Phosphine (PH3) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$318.40 
BWS1-P-Y
(6394)

BW  BWS1-P-Y

BW Solo Serviceable Single-gas Detector for Phosphine (PH3) 0-5 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

P-8434
(6793)

PROSENSE  P-8434

Prosense P-8434 Gas Detector with Electrochemical sensor for Phospine (PH3) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$952.38 
PQN-8434-1/2
(6967)

PROSENSE  PQN-8434-1/2

Prosense PQN-8434 Gas Detector with Electrochemical sensor for Phospine (PH3) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,132.56 
PQD-8434-1/2
(6754)

PROSENSE  PQD-8434-1/2

Prosense PQD-8434 Gas Detector with Electrochemical sensor for Phospine (PH3) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,287.00 
961-200026-005G
(6374)

DETCON  961-200026-005G

Detcon DM-100-PH3 Electrochemical Phosphine (PH3) 0-5ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

31001AL-0-9073/10P/L1
(5788)

RC SYSTEMS  31001AL-0-9073/10P/L1

RC Systems SenSmart 3100 3 wire gas detector for Phosphine (PH3) 0-10ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure with splash guard. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,145.28 
967-192090-005
(6098)

DETCON  967-192090-005

Detcon DM-700-PH3 Electrochemical Smart Phosphine (PH3) 0-5 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSP1SS
(850)

HONEYWELL  XNXUTAENNNNN-XNXXSP1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Phosphine (PH3) 0-1.2ppm compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,391.48 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.