NOTIFIER   RP-2001

NOTIFIER RP-2001
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier RP-2001 Deluge/Preaction six-zone Control Panel for single and dual hazard applications. 4 outputs for NACs or releasing circuits. Three programmable Form-C relays and 24 VDC resettable and non-resettable power outputs. 120 VAC and 240 VAC versions. LCD display. UL, FM and CSFM Approved.

RP-2001   
Please Email us your request for quote   

Version

   6 Weeks  ]

The RP-2001 is a six-zone FACP for single and dual hazard deluge and preaction applications. The RP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The RP-2001 is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.

Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The RP-2001 supervises all wiring, AC voltage, battery charger and battery level.

Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.

The RP-2001E offers the same features as the RP-2001 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and 240 VAC versions of the panels.

Features
  • Listed to UL Standard 864, 9th edition.
  • FM Approved.
  • Designed for sprinkler standards NFPA 13, 15 and 16.
  • Dual hazard operation.
  • Adjustable waterflow discharge timer and two soak timers.
  • Cross-zone (double-interlock) capability.
  • Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
  • System Sensor i 3 series detectors compatible.
  • Four programmable Style Y (Class B) output circuits - (special application power).
  • Strobe Synchronization:
    • System Sensor
    • Wheelock
    • Gentex
    • Faraday
    • Amseco
  • Three programmable Form-C relays.
  • 7.0 amps total 24 VDC output current.
  • Resettable and non-resettable output power.
  • Built-in Programmer.
  • ANN-BUS for connection to optional devices (up to 8 total of any of the following):
    • N-ANN-80 Remote LCD Annunciator
    • N-ANN-I/O LED Driver
    • N-ANN-S/PG Printer Module
    • N-ANN-RLY Relay Module
    • N-ANN-LED Annunciator Module
  • 80-character LCD display (backlit).
  • Real-time clock/calendar with daylight savings time control.
  • History log with 256 event storage.
  • Piezo sounder for alarm, trouble and supervisory.
  • 24 volt DC operation.
  • Low AC voltage sense.
  • Outputs Programmable for:
  • Releasing circuits or NACS
  • NACs programmable for:
  • Silence Inhibit
  • Auto-Silence
  • Strobe Synchronization
  • Selective Silence (horn-strobe mute)
  • Temporal or Steady Signal
  • Silenceable or Non-silenceable
  • Release Stage Sounder
  • Disable/Enable control per input zone and output zone.
  • Extensive transient protection.
  • Automatic battery charger with charger supervision.
  • Optional Dress Panel DP-51050 (red).
  • Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet.
  • Optional N-CAC-5X Class A Converter Module for Outputs and IDCs.
  • Optional 4XTM Municipal Box Transmitter Module.
  • Optional Digital Alarm Communicators (411, 411UD,411UDAC).
  • Optional ANN-SEC card for a secondary ANN-BUS.
  • PROGRAMMING AND SOFTWARE:
    • Custom English labels (per point) may be manually entered or selected from an internal library file.M
    • Three programmable Form-C relay outputs.M
    • Pre-programmed and custom application templates.M
    • Continuous fire protection during online programming at the front panel.M
    • Program Check automatically catches common errors not linked to any zone or input point.M
    USER INTERFACE:
    • Integral 80-character LCD display with backlighting.M
    • Real-time clock/calendar with automatic daylight savings adjustments.M
    • ANN-Bus for connection to remote annunciators.M
    • Audible or silent walk test capabilities.M
    • Piezo sounder for alarm, trouble, and supervisory.M
    NFPA Standards

    The RP-2001(E) complies with the following NFPA 72 Fire Alarm Systems requirements:

    • NFPA 13 Installation of Sprinkler Systems
    • NFPA 15 Water Spray Fixed Systems
    • NFPA 16 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems
    • NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems (requires an optional Remote Station Output Module)
    Agency Listings and Approvals

    The listings and approvals below apply to the basic RP-2001(E) and RP-2001(E)E fire alarm control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

    • UL: S635
    • FM approved
    • CSFM: 7165-0028:0245
    • MEA: 333-07-E

    SYSTEM SPECIFICATIONS
    System Capacity 8 Annunciators
    Electrical Specifications RP-2001 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps.
    RP-2001E (FLPS-7 Power Supply): 240 VAC, 50/60 Hz, 2.085 amps.
    Wire size minimum 14 AWG (2.0 mm²) with 600 V insulation, supervised, nonpower-limited.
    Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR- CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide.
    Weight: 20.7 lbs. (9.4 kg)
    Dimensions: – Height 20.00" (50.80cm)
    – Width 22.50" (57.15cm)
    – Depth 8.50" (21.59cm)
    Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F.
    Export Info
    Made inUnited States

     Info/Quote Request
     Reseller & Volume Discounts
     Shipping Rates

    B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
    Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

    Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

    > ACCESSORIES - RELATED - CONSUMABLES :    11 Items found.
    FST-951
    (3228)

    NOTIFIER  FST-951

    Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

    FMM-1
    (3695)

    NOTIFIER  FMM-1

    Notifier FMM-1/FMM-101 Series Monitor Module for supervised dry-contact input devices or monitor and power two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.

    FSP-951
    (2038)

    NOTIFIER  FSP-951

    NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

    FRM-1
    (3694)

    NOTIFIER  FRM-1

    Notifier FRM-1 Series Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. Two Form-C dry contacts. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



     
    FCM-1
    (3236)

    NOTIFIER  FCM-1

    Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



     
    NBG-12LX
    (2042)

    NOTIFIER  NBG-12LX

    NOTIFIER by Honeywell NBG-12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel.

    FCO-951
    (3502)

    NOTIFIER  FCO-951

    Notifier IntelliQuad® PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



     
    FSV-951R
    (3229)

    NOTIFIER  FSV-951R

    Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW®) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360° viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

    XP10-M
    (3724)

    NOTIFIER  XP10-M

    Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan® or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



     
    ACPS-610
    (6936)

    NOTIFIER  ACPS-610

    Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

    HS-NCM-MF__
    (4326)

    NOTIFIER  HS-NCM-MF

    Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET™ with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

    > SMOKE THERMAL IONIZATION :    1 Items found.
    NFS-320
    (2039)

    NOTIFIER  NFS-320

    NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

    Cookie Notice

    This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.