Intec Sgc6-00 | Multi-gas (fixed) | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

INTEC   SGC6-00

INTEC SGC6-00
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Intec Controls PolyGard 2 SGC6 Standalone Gas Controller for up to 2 local and 1 remote SC2 sensors. Detects Carbon Monoxide, Ammonia, Nitrogen Dioxide, Formaldehyde, Ozone, Chlorine, Oxygen, Sulphur Dioxide, Hydrogen Sulfide, Carbon Dioxide, Methane, Ethyl Alcohol, Hydrogen, Propane or Gasoline Vapor. Wall Mounted. 2 SPDT alarm relays, 1 4-20mA analog input and 1 4-20mA analog output. Digital, RS-485, Modbus-RTU and DGC6 protocols. Audible and visual alarm. Multi-color LCD Display. 24 VAC/VDC. NEMA 4X enclosure. IP65. UL and SIL2 Listed.

SGC6-00   
561.00

Local SC2 Sensor
Local SC2 Sensor

   3 Days  ]
DESCRIPTION

Wall-mounted, NEMA 4X standalone ventilation controller with one, two, or three high-performance SC2-Series gas sensor modules.

Intuitive, menu-driven setup allows on/off, multi-speed, and variable speed control of ventilation equipment in response to user-specified gas concentration levels.

Multi-color LCD and standard horn/light module for local annunciation of escalating alarm levels.

Conforming to Safety Integrity Level 2 (SIL 2) and rigorous international standard EN 50545-1 for parking garages and tunnels, PolyGard ® 2 monitoring and control systems utilize advanced self-diagnostics and flexible ventilation control functions to ensure maximum human safety without compromising energy efficiency.

Advanced, microprocessor-based X-Change sensor modules meet or exceed the EN 50545-1 self diagnostic standards including notifying the controller when calibration is due. Although field calibration is possible, X-Change technology allows fast and cost effective sensor module swaps minimizing field service time, eliminating system downtime and ensuring peak system performance for many years.

APPLICATION

To detect and control levels of toxic and combustible gases in a wide variety of commercial applications such as carbon monoxide and nitrogen dioxide levels in parking structures, package sorting hubs, vehicle repair shops, tunnels, and equipment rooms. Although typically operating as a standalone controller directly activating ventilation equipment in response to rising gas levels, the SGC6 can also work in conjunction with building management systems via Modbus serial communications, analog (gas value) or binary (threshold / relay) output signals.

FEATURES
  • 1 or 2 on-board SC2-Series gas sensor modules
  • Optional 3rd gas sensor input with DR6 Digital Remote sensor
  • 2-Line, 16-character LCD display with dual color background
  • Two (2) SPDT alarm relays, 30 VAC/VDC, 0.5 A
  • One (1) 4-20mA analog output
  • Audible / visual alarm annunciation
  • RS-485 serial communications to DGC6-Series Digital Gas Controllers or other Modbus controllers
  • 24 VAC/VDC powered
  • Menu-driven controller setup
  • X-Change sensor technology for low-cost life cycle maintenance
  • Digital measurement processing with temperature compensation
  • Internal diagnostics including integrated hardware watchdog
  • High-impact polycarbonate enclosure, NEMA 4X (IP65)
  • Software conforms to SIL 2 standard

Specifications
Electrical
Power supply 24 VDC ±20%, reverse polarity protected;
24 VAC -10%/+15%, VAC allowed for standalone configuration only
Power consumption
base (with LCD)
sensors
horn & multi-status LED
analog output
24 VDC
80 mA
See SC2 datasheet
5 mA
22 mA
Alarm relays Two (2), 30 VAC/VDC, 0.5 A, potential‑free, contacts (SPDT);
1 alarm & 1 fault/alarm
Analog input One (1), 4-20 mA overload and short-circuit proof, input resistance 200 Ω
Analog output signal One (1), proportional, overload and short-circuit proof, load ≤ 500 Ω 4-20 mA = measuring range;
3.0 < 4 mA = under range;
> 20-21.2 mA = over range;
2.0 mA = fault
Output for local bus 5 VDC, 250 mA max.
Overload, short-circuit and polarity protected
Output signal for serial communication Digital, RS-485, Modbus-RTU and DGC6 protocol, 19200 baud
Horn & Status LED
Horn acoustic pressure > 85 dB (A) (dist. 0.1 m / 0.3 ft)
Horn frequency 2300 Hz
Horn protection class NEMA 4X (IP65)
Status LED color / mode Red = Alarm;
Yellow = Fault;
Green = Power (Normal);
Green (flashing) = Service
Status LED protection class NEMA 4X (IP65)
Liquid Crystal Display
LCD Two lines, 16 characters each, illuminated
Serial interface
local bus plug connector / 19200 Baud
field bus RS-485 / 19200 Baud
tool bus 2-wire / 19200 Baud
Physical
Enclosure “C”, standard material Polycarbonate, UL94 V-2, fire retardant
Enclosure color Light gray
Enclosure protection NEMA 4X (IP 65)
Enclosure installation Wall (surface) mounted, or single gang electrical box
Enclosure Dimensions (H x W x D) 5.12 x 5.12 x 2.95 in (130 x 130 x 75 mm)
Cable entry, knock outs 3 holes for 1/2 in. conduit, closed with silver “plugs”
Wire connection local bus (SC2): 3-pin removable connector
remote sensor (DR6): 3-wire, max. length 16.4 ft (5 m)
analog output: Screw-type terminal; 24 AWG (0.25 mm 2 ), min. 16 AWG (1.3 mm 2 ), max.
power supply, relays: Screw-type terminal; 24 AWG (0.25 mm 2 ), min. 14 AWG (2.5 mm 2 ), max.
Weight 1.32 lb (0.6 kg)
Conforms to EMC Directive 2014/30/EU
LVD 2014/35/EU
EN 50271
EN 61010-1:2010
ANSI/UL 61010-1
CAN/CSA-C22.2 No. 61010-1
Warranty Two years material and workmanship, 12 months normal exposure for sensor element

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.