Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (6915)

RC SYSTEMS  1100ALD-109024/007P

$914.78     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



RC SYSTEMS 1100ALD-109024/007P (1)
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE

RC Systems SenSmart 1100 gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 1 (Explosion Proof).

Part# with Options:        1100ALD-109024/007P
Price with Options:        914.78

Options:    

Sensor Range
(1) Sensor Range for RC Systems SenSmart NO2
Enclosure Type
(2) Enclosure Type for RC Systems 1000 Div 1

  Availability 2 Weeks  ]


The RC Systems SenSmart 1100/1200/1300 are complete 2 or 3 wire Gas Detectors available in UL94 flame retardant plastic, or, Class 1 Div 1 316 stainless steel sensor head enclosures These easy-to-install and maintain gas detectors must be connected to an R. C. Systems single or multi-channel receiver to add user calibration and readout functions.

SenSmart 1100 utilizes our electrochemical temperature controlled SMART sensors to transmit O2, H2S, SO2, Cl2, HF, HCL, NO2 (to name a few) 2-wire 4-20mA gas values to R. C. Systems single and multi-channel receivers.

The SenSmart 1200, 1300, 1400 and 1500 utilize our 3-wire direct “bridge” sensor input, including catalytic, PID and infrared, to detect methane, propane, VOC’s, benzene, CO2 and many other compounds. The bridge output is compatible with R. C. Systems single and multi-channel receivers.

FEATURES HIGHLIGHT
  • Field swappable sensor module. Range and target gas configured on sensor module
  • Improves system noise immunity because low level sensor signals are protected within the sensor head
  • Industry standard 4-20mA signal may be transmitted thousands of feet on 2-wires
  • 316 SS model is suitable for Class 1 Div 1 hazardous areas.
  • Missing or failed sensor forces <2mA FAULT signal
  • Compatible with 1, 2, 4, 16 and 64 channel Receiver/Controllers (user calibration & readout are at the Receiver)
  • 2-wire milliamp signal is nonpolar with protective “steering diodes”

SPECIFICATIONS
Power SupplySenSmart 1100: 9-36 VDC @ 25mA 9-36 VDC @ 25mA
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor 2-4.25 VDC sensor specific
Accuracy+/- 1% of full scale range (typical)
Standard OutputSenSmart 1100 : Standard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor output
TempLess than .1% per degree C over ambient temperature range
Housing316 Stainless or aluminum enclosure suitable for Class 1 Groups A,B,C,D; Class 2, Groups E,F,G
Ul94 Poly Black Plastic Enclosure
ApprovalsDivision 1 and 2 Group A,B,C,D Exia. Suitable for Explosion Proof and Intrinsically Safe installations
UL94 Poly Black Plastic Enclosure: Non-Incendive Cl 1 Div 2 Gr ABCD
 


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
CYL-10474525
(4726)

PORTAGAS  CYL-10474525

Calibration Gas Nitrogen Dioxide (NO2) 10 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$211.36 
CYL-10474553
(1507)

PORTAGAS  CYL-10474553

Calibration Gas Nitrogen Dioxide (NO2) 50 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$211.36 
ISC-1810-2219-EQUIV
(2585)

PORTAGAS  ISC-1810-2219-EQUIV

Calibration Gas Nitrogen Dioxide 5ppm Balance Nitrogen 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID tag)

Configure

$264.49 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,486.18 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,108.42 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. User-friendly and visually powerful. UL and CSA approved for Class I, Division 2. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. 5 amp resistive Form C relays. Optional 4-20mA inputs/outputs and RS-485 serial port.

Configure

$10,740.31 
> NITROGEN DIOXIDE :    30 Items found.
PPS+-NO2
(6814)

PROSENSE  PPS+-NO2

Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



$261.00 
M001-0011-000
(6004)

MPOWER  M001-0011-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitrogen Dioxide (NO2) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$268.20 
TX1-4
(5967)

INDUSTRIAL SCIENTIFIC  TX1-4

Industrial Scientific Tango TX1 Gas Detector for Nitrogen Dioxide (NO2) 1-150 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

PC3-6824
(6809)

PROSENSE  PC3-6824

Prosense PC3-6824 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$396.00 
BWS_-D-Y
(6391)

BW  BWS-D-Y

BW Solo Serviceable Single-gas Detector for Nitrogen dioxide (NO2) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

10154078
(4445)

MSA  10154078

MSA ALTAIR 2X Portable Single Gas Detector with XCell Sensor Technology for Nitrogen Dioxide (NO2) Range 0-50 ppm. Low Alarm 2.5ppm, High Alarm 5ppm. Polycarbonate Housing. 25 feet drop test. 95dB audible alarm. Monochrome LCD Display. IP67. cCSAus, ATEX and IEC Approved.

Configure

$522.00 
G02-B510-100
(3020)

RAE  G02-B510-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Nitrogen Dioxide (NO2) 0-20 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

6302-0041
(6235)

BACHARACH  6302-0041

Bacharach MGS-410 Gas Detector Transmitter with electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$538.20 
6302-1041
(6245)

BACHARACH  6302-1041

Bacharach MGS-450 Gas Detector Transmitter with electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$603.00 
TX-6-ND
(2046)

MACURCO  TX-6-ND

Macurco TX-6-ND low voltage Gas Detector, Controller and Transducer for Nitrogen Dioxide (NO2) 0-20 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1.

Configure

$603.00 
TX-12-ND
(3417)

MACURCO  TX-12-ND

MACURCO TX-12-ND line voltage Gas Detector, controller and transducer for Nitrogen Dioxide (NO2) 0-20ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$609.75 
P-6834
(6784)

PROSENSE  P-6834

Prosense P-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$693.00 
6302-4041
(6255)

BACHARACH  6302-4041

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$740.70 
364-455-01-365-732-01
(6156)

DELPHIAN  364-455-01-365-732-01

Delphian GazTell Fixed Point Electrochemical Gas Detector for Nitrogen Dioxide (NO2) 0-100ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$768.00 
SPSTAXN1
(1924)

HONEYWELL  SPSTAXN1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Nitrogen dioxide (NO2) 0-10ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$804.52 
GG-NO2-B-10
(5982)

CALIBRATION TECHNOLOGIES  GG-NO2-B-10

CTI GG-NO2-B Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. NEMA 3RX polycarbonate housing. CSA and UL approved.

Configure

$900.90 
2106B1422
(1467)

HONEYWELL  2106B1422

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitrogen Dioxide (NO2) 0-10 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$921.03 
PQN-6834-1/2
(6957)

PROSENSE  PQN-6834-1/2

Prosense PQN-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$945.00 
PQD-6834-1/2
(6745)

PROSENSE  PQD-6834-1/2

Prosense PQD-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,071.00 
6600-8024
(6270)

BACHARACH  6600-8024

Bacharach MGS-550 Industrial Refrigerant Gas Detector with electrochemical sensor for Nitrogen Dioxide (NO2) 0-20ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. CE, UL and CSA Approvals.

Configure

$1,099.80 
Page: 1 | 2 | All