Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (6912)

RC SYSTEMS  1100ALD-109020/30P

$914.78     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



RC SYSTEMS 1100ALD-109020/30P (1)
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE

RC Systems SenSmart 1100 gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 1 (Explosion Proof).

Part# with Options:        1100ALD-109020/30P
Price with Options:        914.78

Options:    

Enclosure Type
(1) Enclosure Type for RC Systems 1000 Div 1

  Availability 2 Weeks  ]


The RC Systems SenSmart 1100/1200/1300 are complete 2 or 3 wire Gas Detectors available in UL94 flame retardant plastic, or, Class 1 Div 1 316 stainless steel sensor head enclosures These easy-to-install and maintain gas detectors must be connected to an R. C. Systems single or multi-channel receiver to add user calibration and readout functions.

SenSmart 1100 utilizes our electrochemical temperature controlled SMART sensors to transmit O2, H2S, SO2, Cl2, HF, HCL, NO2 (to name a few) 2-wire 4-20mA gas values to R. C. Systems single and multi-channel receivers.

The SenSmart 1200, 1300, 1400 and 1500 utilize our 3-wire direct “bridge” sensor input, including catalytic, PID and infrared, to detect methane, propane, VOC’s, benzene, CO2 and many other compounds. The bridge output is compatible with R. C. Systems single and multi-channel receivers.

FEATURES HIGHLIGHT
  • Field swappable sensor module. Range and target gas configured on sensor module
  • Improves system noise immunity because low level sensor signals are protected within the sensor head
  • Industry standard 4-20mA signal may be transmitted thousands of feet on 2-wires
  • 316 SS model is suitable for Class 1 Div 1 hazardous areas.
  • Missing or failed sensor forces <2mA FAULT signal
  • Compatible with 1, 2, 4, 16 and 64 channel Receiver/Controllers (user calibration & readout are at the Receiver)
  • 2-wire milliamp signal is nonpolar with protective “steering diodes”

SPECIFICATIONS
Power SupplySenSmart 1100: 9-36 VDC @ 25mA 9-36 VDC @ 25mA
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor 2-4.25 VDC sensor specific
Accuracy+/- 1% of full scale range (typical)
Standard OutputSenSmart 1100 : Standard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor output
TempLess than .1% per degree C over ambient temperature range
Housing316 Stainless or aluminum enclosure suitable for Class 1 Groups A,B,C,D; Class 2, Groups E,F,G
Ul94 Poly Black Plastic Enclosure
ApprovalsDivision 1 and 2 Group A,B,C,D Exia. Suitable for Explosion Proof and Intrinsically Safe installations
UL94 Poly Black Plastic Enclosure: Non-Incendive Cl 1 Div 2 Gr ABCD
 


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
CYL-90094700
(610)

PORTAGAS  CYL-90094700

Calibration Gas Hydrogen Cyanide HCN 10 ppm Balance Nitrogen, 34 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$149.31 
CYL-10320254
(1310)

PORTAGAS  CYL-10320254

Calibration Gas Hydrogen Cyanide (HCN) 10 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$211.36 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,486.18 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,108.42 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. User-friendly and visually powerful. UL and CSA approved for Class I, Division 2. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. 5 amp resistive Form C relays. Optional 4-20mA inputs/outputs and RS-485 serial port.

Configure

$10,740.31 
> HYDROGEN CYANIDE :    15 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$313.20 
BWS_-Z-Y
(6388)

BW  BWS-Z-Y

BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

G02-B710-100
(3022)

RAE  G02-B710-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen Cyanide (HCN) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

10076729
(1660)

MSA  10076729

MSA ALTAIR Pro Portable Single-gas Detector for Hydrogen Cyanide (HCN) 0-30 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 4.7 ppm, High 10 ppm, STEL 10 ppm, TWA 4.7 ppm



$635.27 
364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$897.60 
P-7534
(6789)

PROSENSE  P-7534

Prosense P-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,044.00 
PQN-7534-1/2
(6962)

PROSENSE  PQN-7534-1/2

Prosense PQN-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,170.00 
PQD-7534-1/2
(6750)

PROSENSE  PQD-7534-1/2

Prosense PQD-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,296.00 
2100AL-0-9020/30P/L0
(127)

RC SYSTEMS  2100AL-0-9020/30P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Poly or aluminum enclosure. Suitable for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,478.49 
961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

Configure

$1,479.21 
S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-30ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,704.47 
31001AL___-0-9020/30P/L0
(5783)

RC SYSTEMS  31001AL-0-9020/30P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 1 (Explosion Proof).

Configure

$1,722.50 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical "Smart" Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Configure

$1,948.46 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,103.21 
EX-HCN-50P-O
(6027)

MACURCO  EX-HCN-50P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Cyanide (HCN) 0-50ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. CSA approvals for Class I Division 2.

Configure

$2,268.75