Rc Systems 1100ald-109019/10p-l0 | Hydrogen Chloride | Gas Detectors (division 2 Non-incendive) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

RC SYSTEMS   1100ALD-109019/10P-L0

RC SYSTEMS 1100ALD-109019/10P-L0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
RC Systems SenSmart 1100 gas detector for Hydrogen Chloride (HCl) 0-10 to 0-30ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

1100ALD-109019/10P-L0   
1,801.30

Sensor Range
Enclosure Type
Splash Guard

   3 Weeks  ]
8 Variants of base SKU

The RC Systems SenSmart 1100/1200/1300 are complete 2 or 3 wire Gas Detectors available in UL94 flame retardant plastic, or, Class 1 Div 1 316 stainless steel sensor head enclosures These easy-to-install and maintain gas detectors must be connected to an R. C. Systems single or multi-channel receiver to add user calibration and readout functions.

SenSmart 1100 utilizes our electrochemical temperature controlled SMART sensors to transmit O2, H2S, SO2, Cl2, HF, HCL, NO2 (to name a few) 2-wire 4-20mA gas values to R. C. Systems single and multi-channel receivers.

The SenSmart 1200, 1300, 1400 and 1500 utilize our 3-wire direct “bridge” sensor input, including catalytic, PID and infrared, to detect methane, propane, VOC’s, benzene, CO2 and many other compounds. The bridge output is compatible with R. C. Systems single and multi-channel receivers.

Improved design and direct replacement of the GDS Corp. GDS-49

FEATURES HIGHLIGHT
  • Field swappable sensor module. Range and target gas configured on sensor module
  • Improves system noise immunity because low level sensor signals are protected within the sensor head
  • Industry standard 4-20mA signal may be transmitted thousands of feet on 2-wires
  • 316 SS model is suitable for Class 1 Div 1 hazardous areas.
  • Missing or failed sensor forces <2mA FAULT signal
  • Compatible with 1, 2, 4, 16 and 64 channel Receiver/Controllers (user calibration & readout are at the Receiver)
  • 2-wire milliamp signal is nonpolar with protective “steering diodes”

SPECIFICATIONS
Power SupplySenSmart 1100: 9-36 VDC @ 25mA 9-36 VDC @ 25mA
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor 2-4.25 VDC sensor specific
Accuracy+/- 1% of full scale range (typical)
Standard OutputSenSmart 1100 : Standard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor output
TempLess than .1% per degree C over ambient temperature range
Housing316 Stainless or aluminum enclosure suitable for Class 1 Groups A,B,C,D; Class 2, Groups E,F,G
Ul94 Poly Black Plastic Enclosure
ApprovalsDivision 1 and 2 Group A,B,C,D Exia. Suitable for Explosion Proof and Intrinsically Safe installations
UL94 Poly Black Plastic Enclosure: Non-Incendive Cl 1 Div 2 Gr ABCD
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
CYL-90097257
(931)

PORTAGAS  CYL-90097257

Calibration Gas Hydrogen Chloride (HCl) 10 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$252.43 
10-9019-10P
(7101)

RC SYSTEMS  10-9019-10P

RC Systems 10-9019/10-9517 Gen I EC Smart Sensor for Series 1000, 2000, 3000 Gas Detectors with ST-48 transmitter, Hydrogen Chloride (HCL) up to 30ppm (0-10, 0-30)ppm

Configure

$1,087.01 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Division 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20mA inputs.

Configure

$12,179.52 
> HYDROGEN CHLORIDE :    13 Items found.
M001-0008-000
(5998)

MPOWER  M001-0008-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Chloride (HCI) 0-15ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$518.40 
P-7934
(6791)

PROSENSE  P-7934

Prosense P-7934 Gas Detector with Electrochemical sensor for Hydrogen Chloride (HCl) with range 0-50ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
PQN-7934-1/2
(6964)

PROSENSE  PQN-7934-1/2

Prosense PQN-7934 Gas Detector with Electrochemical sensor for Hydrogen Chloride (HCL) with range 0-50ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,338.48 
PQD-7934-1/2
(6752)

PROSENSE  PQD-7934-1/2

Prosense PQD-7934 Gas Detector with Electrochemical sensor for Hydrogen Chloride (HCL) with range 0-50ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,492.92 
961-090026-030G
(6365)

DETCON  961-090026-030G

Detcon DM-100-HCL Electrochemical Hydrogen Chloride (HCl) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

S3KUL2-XNXXSR1SS
(692)

HONEYWELL  S3KUL2-XNXXSR1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CHLORIDE (HCI) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-10ppm, user adjustable (10.0 to 20.0ppm, 1.0ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,782.81 
41001AL-0-1014/0010P/L0
(7164)

RC SYSTEMS  41001AL-0-1014/0010P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen Chloride (HCl) 0-10 to 0-30ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,025.97 
51001AL-0-1014/0010P/L0
(7127)

RC SYSTEMS  51001AL-0-1014/0010P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Chloride (HCl) 0-10 to 0-30ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$2,081.82 
967-090990-030
(6090)

DETCON  967-090990-030

Detcon DM-700-HCL Electrochemical Smart Hydrogen Chloride (HCL) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSR1SS
(843)

HONEYWELL  XNXUTAENNNNN-XNXXSR1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Chloride (HCl) 0-10ppm, user adjustable (10.0 to 20.0ppm, 1.0ppm increments) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,268.94 
2100AL-0-9019/10P/L0
(129)

RC SYSTEMS  2100AL-0-9019/10P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Chloride (HCl) 0-10 to 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,276.62 
31001AL-0-9019/10P/L0
(6890)

RC SYSTEMS  31001AL-0-9019/10P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Chloride (HCl) 0-10 to 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,454.54 
6100AL1-0-1014/0010P
(7006)

RC SYSTEMS  6100AL1-0-1014/0010P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Chloride (HCl) 0-10 to 0-30ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,876.62 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.