Features and Benefits
- Measures Particles in Four Sizes: >4, >6, >14 and >21 microns
- In-line or Manifold Mounting
- ISO or SAE codes can be output in 4-20 mA
- Compatible with Standard Mineral Fluids & Phosphate Esters
- Display and Keypad can be rotated (up to 270°)
- Inlet and Outlet Ports are Interchangeable (bidirectional) (without manifold only)
- Recommended recalibration: Only every 2 years
The Contamination Sensor 1000 (CS 1000) continuously measures solid contamination in hydraulic fluid.
Enclosed in a 4-inch diameter case, the CS 1000 utilizes an optical sensor and measures particles in four
sizes: >4, >6, >14 and >21 microns. Measurement results can be output as a contamination code according
to ISO 4406:1999 or SAE AS 4059(D).
The CS 1000 is designed for connection to hydraulic and lubrication lines with pressures up to 5075 psi (350 bar) and viscosities up to 4635 SUS (1000 cSt). The unit requires that a small flow of oil (between 30 mL/min and 500 mL/min) is diverted for measurement purposes.
The CS 1000 provides the user with a smaller, tougher, and more versatile stationary sensor. It provides instantaneous readings and is able to self-diagnose continuously with error indication via the status LED.
The attractive cost-to-performance ratio makes it especially applicable for OEM applications. Online,
real-time condition monitoring allows you to have total predictive maintenance.