Notifier Lcm-320 | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   LCM-320

SKU# (6871)
NOTIFIER LCM-320
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.

Please Email us your request for quote   

   4 Weeks  ]

The LCM-320 Loop Control Module and the LEM-320 Loop Expander Module provide NOTIFIER’s ONYX® Series of Fire Alarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). The ONYX® Series NFS-640/NFS2-640 supports one LEM-320; the NFS-3030/NFS2-3030 supports up to five LCM-320s and five LEM-320s. The LEM-320 module is used to expand the NFS-640/NFS2-640 to a second loop, and to expand each LCM-320 used on the NFS-3030/NFS2-3030 — each NFS-3030/NFS2-3030 LCM-320 supports an expansion LEM-320.

Features
  • Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop (twisted-unshielded).
  • Built-in degraded mode increases survivability.
  • Very simple installation — plug-in style.
  • Permits multiple loops in small enclosure.
Product Line Information

LCM-320: Loop Control Module. Adds SLCs to NFS-3030/ NFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s.

Agency Listings and Approvals

The listings and approvals below apply to the basic LCM-320 and LEM-320. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status.

  • UL: S635
  • ULC: S635/CS118
  • FM Approved
  • CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 with NFS-3030/NFS2-3030). 7165-0028:214, 7170-0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170-0028:244 (LEM-320 with NFS2-640).
  • FDNY: COA#6025 (LEM-320 with NFS2-640)
  • FDNY: COA#6026 (LCM-320/LEM-320 with NFS2-3030)
  • City of Denver
  • Hong Kong

Specifications
Voltage 24 VDC nominal, 27.6 VDC maximum.
Maximum loop length The maximum wiring distance of an SLC using 12 AWG (3.1 mm²) twisted-pair wire is 12,500 feet (3810 m) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm²) to 18 AWG (0.78 mm²):
Distance with 12 AWG: 12,500 ft (3,810 m).
Distance with 14 AWG: 8,000 ft (2,438 m).
Distance with 16 AWG: 4,875 ft (1,486 m).
Distance with 18 AWG: 3,225 ft (983 m).
50 ohms maximum per length of Style 6 & 7 loops.
50 ohms maximum per branch for Style 4 loop.
Maximum current 130 mA; for single SLC loop: 400 mA maximum.
NOTE: Maximum short circuit — loop will shut down until short-cir- cuit condition is corrected.
Maximum resistance 50 ohms (supervised and power-limited).
Temperature and humidity ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F.
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment