Notifier Ldm-32 | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   LDM-32

SKU# (6870)
NOTIFIER LDM-32
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier LDM-32 Lamp Driver Module for annunciation and control of NOTIFIER Intelligent Fire Alarm Control Panels. Up to 32 alarm indications. 24 VDC. EIA-485 interface. UL, ULC, MEA, CSFM and FM Listed.

Please Email us your request for quote   

   4 Weeks  ]

The LDM Series lamp driver modules, when combined with a custom graphic display, provide annunciation and control for Notifier’s intelligent fire alarm control panels. These modules use a serial communications interface, and may be located up to 6,000 feet from the panel.

Features
  • ALARM/CIRCUIT ON and TROUBLE lamp/LED per-point option, or more dense alarm-only option (field selectable).
  • Control switch option for remote control per point.
  • Lamps/LEDs may be programmed to display status of indicating circuits or control relays as well as system status conditions.
  • System trouble lamp/LED signal.
  • On-line/power LED indicator.
  • Alarm and trouble resound with flash of new conditions.
  • Local sounder for both alarm/circuit-on and trouble conditions with silence/acknowledge switch connection.
  • Serial EIA-485 interface for reduced installation costs.
  • May be powered by 24 VDC from the panel or by remote power supplies.
  • Efficient switch-power converter reduces power consumption.
  • Microprocessor-controlled electronics, fully supervised.
  • Plug-in terminal blocks for ease of installation and service.
  • Trouble monitor option for remote power supplies.
Construction

Two basic models are available; the LDM-32 control module and the LDM-E32 expander module. Each may be selected to provide 32 alarm indications; or 16 alarm, 16 trouble, and 16 control points.

Applications

The LDM-32/LDM-E32 with a custom graphic array may be used to indicate point status and, in some versions, to control the state of output points.

In addition, the LDM-R32 module may be used to provide 32 dry-contact relays for electrical isolation when connecting the system to other equipment.

Installation

The LDM-32 and LDM-E32 modules mount on four standoffs inside the custom annunciator graphic box. Alternately, the modules may be installed in a CHS-4L chassis. The module size is approximately 4.4” (11.2cm) x 7.1” (18cm).

Communications between the LDM Series annunciators and the host FIre Alarm Control Panel are made through a two-wire EIA-485 multi-drop loop, and a two-wire regulated 24 VDC power loop. Up to 32 LDM systems may be connected to a single control panel.

All field-wiring terminations use removable, compression-type terminal blocks for ease of installation, wiring, and circuit test- ing.

Operation

LDM Series modules, when used with a custom graphic annunciator, provide the Notifier’s intelligent fire alarm control panels with up to 32 unique or redundant annunciators, each with a capacity of 64 points for a total capacity of 2048 points.

Local or remote power supplies and serial communications allow the custom annunciators to be located anywhere on the protected premises.

AM2020/AFP1010 system alarm and/or trouble conditions may be annunciated on a per-point basis, or in a grouped-zone configuration.

AFP300/400 system panel points, intelligent addressable devices and software zones can be annunciated/controlled in a grouped fashion (see programming manual for details).

Control of system operational controls, such as Signal Silence, System Reset, and local annunciation controls (such as Local Acknowledge), and Lamp Test may be accomplished through special key- or push-switches.

Agency Listings and Approvals

These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S635
  • ULC Listed: S635
  • MEA Listed: 291-61-E Vol. 4 (System 500, LDM-R32); 289-91-E Vol. V (AM2020/AFP1010); 104-93-E (AFP-200); 17-96-E (AFP-300/400); 447-99-E (AFC-600)
  • CSFM: 7120-0028:0156, 7165-0028:0224 (NFS-3030, NFS2-3030); 7170-0028:0223 (NFS-3030, NFS2-3030)
  • BSA: 578-81-SA (System 5000, System 500 except LDM-R32)
  • FM Approved
  • City of Chicago approved: Class 1, Class 2
  • City of Denver approved
  • FDNY COA #6085 (NFS2-640); 6065 (NFS2-3030)
Product Line Information

LDM-32: Lamp Driver Module with 32 alarm lamp-driver tran- sistors (sink to power common on alarm). May be selected (dip switch) for 16 alarm/circuit on, 16 trouble, and 16 switch inputs if desired. Also includes system-trouble lamp driver and lamp-test/local-acknowledge switch input. Integral piezo sounder sounds for each new alarm or trouble and is silenced with the Local Acknowledge switch, or permanently disabled with a dip switch selection. Flash of new alarms or troubles is selectable through dip switches. 16 switch inputs may be used for panel SILENCE, RESET, or remote relay control. Instructions are included.

Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    40 Items found.
PF24V
(3237)

NOTIFIER  PF24V

Notifier PF24V ExitPoint Directional Sounder with Voice Messaging designed for open areas, corridors or stairs. Reduces evacuation times up to 75%. 24VDC. UL, FM, CSFM and MEA Approved.



 
BAT-1270-BP
(6944)

NOTIFIER  BAT-1270-BP

Notifier BAT-1270-BP rechargeable battery. 12VDC. 7 AH. 5-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12550
(6943)

NOTIFIER  BAT-12550

Notifier BAT-12550 rechargeable battery. 12VDC. 55 AH. Overcharge protected. ABS high-impact case.



 
BAT-12260-BP
(6941)

NOTIFIER  BAT-12260-BP

Notifier BAT-12260-BP rechargeable battery. 12VDC. 26 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
ISO-6
(6934)

NOTIFIER  ISO-6

Notifier ISO-6 Six Fault Isolator Module for Notifier Fire Alarm Control Panels (FACPs). Powered by SLC loop. Class B isolator circuits. UL, FM, CSFM Approved.



 
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

APS2-6R
(6938)

NOTIFIER  APS2-6R

Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HPFF12
(6600)

NOTIFIER  HPFF12

Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.