Simplex Tyco 4906-9102 | Horns | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SIMPLEX TYCO   4906-9102

SKU# (6851)



SIMPLEX TYCO 4906-9102

ALARM SIGNAL DEVICES / INDOOR
HORNS

  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex Tyco 4906-91XX TrueAlarm Non-Addressable multi-candela high intensity Strobe. Ceiling-Mounted. 24VDC. 1 Hz. 15, 30, 75, or 110 candela intensity selectable. High impact flame retardant housing. NEMA 1. Complies with ADA requirements. UL listed.

4906-9102   
Please Email us your request for quote   

Version

   4 Weeks  ]
Features Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount:
  • Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing
  • Operation is compatible with ADA requirements (refer to Installation Reference, Surface or Semi-Flush Wall Mounting)
  • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC)
  • Regulated circuit design ensures consistent flash output and provides controlled inrush current
  • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens
  • Listed to UL 1971 and ULC S526
  • NEMA 1 rated. See Product Selection for more information
Strobes provide synchronized flash for use with:
  • Simplex fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control
  • 4009 IDNet NAC Extenders
  • Separate strobe Synchronization Modules that are available for Class B or Class A operation
  • Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs
Strobe housings provides flexible, easy, and convenient semiflush or surface wall mounting:
  • Rear of housing does not extend into box
  • Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box
  • Ceiling mount strobes mount to single gang boxes
Optional adapters and wire guards:
  • Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to 2975-9145 boxes
  • UL listed red wire guards are available for wall or ceiling mount strobes*
Description

Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated.

Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number.

Strobe Intensity Selection

Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

Synchronized Strobes

Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules.

SmartSync Two-Wire Control

Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until- silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation).

Specifications
Rated Voltage RangeRegulated 24 VDC; see Note 1 below
Flash Rate1 Hz
Synchronized NAC LoadingUp to 35 synchronized strobes maximum per NAC
Temperature Range32° to 122° F (0° to 50° C)
Humidity Range10% to 93%, non-condensing at 100° F (38° C)
ConnectionsTerminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ); two wires per terminal for in/out wiring
Housing Dimensions (with lens)4-3/4" L x 2-5/16" W x 2-5/8" D (121 mm x 75 mm x 67 mm)
Maximum RMS Current Rating per Strobe Setting (see Note 2 below)15 cd: 75mA
30 cd: 125mA
75 cd: 233mA
110 cd: 316mA

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    73 Items found.
IS-PA1-G
(3692)

E2S  IS-PA1-G

E2S IS-pA1 compact Panel Mount Sounder 90dB(A). 16-28VDC. Produces a high frequency continuous tone. Ideal for control panels. IP66. ATEX, IECEx and GOST-R approved.



 
HA105NDC024G
(3654)

E2S  HA105NDC024G

E2S HA105N Electronic Siren, Buzzer, Claxon and Bell 112dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC or 230VAC Versions. IP66. GOST-R approved.

MA112DC024G
(3606)

E2S  MA112DC024G

E2S MA112 Alarm Horn Sounder 119dB(A). High output. With robust and fire retardant IP66 & IP67 housing. Suitable for harsh environments. Automatic synchronisation and Stainless Steel fixings. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. GOST-R Approved.

HA121DC024R
(3648)

E2S  HA121DC024R

E2S HA121 Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66. GOST-R approved.

D105DC024R
(5126)

E2S  D105DC024R

E2S D105 high output, 112dB(A) Alarm Sounder. Low current consumption and high SPL. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. Marine grade aluminium housing. Stainless steel fixings. Programmable version available. IP66. UL & cULs approved.

A121DC_24R
(3277)

E2S  A121DC24R

E2S A121 very high output Alarm Sounder 126dB(A). High SPL. 24VAC, 115VAC, 230VAC, 24V or 48V Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. UL version available.

A121AXDC024R-UL
(3281)

E2S  A121AXDC024R-UL

E2S A121AX Appello X User Recordable Alarm Sounder 112dB(A). Low current consumption. 10-30VDC or 90-250VAC Versions. Robust fire retardant Type 4/4X/3R/13, IP66 housing. UL approved.

HMA121DC024G
(3652)

E2S  HMA121DC024G

E2S HMA121 Electronic Siren, Buzzer, Claxon and Bell 124dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66 & IP67. GOST-R approved.

D112DC024R
(5127)

E2S  D112DC024R

E2S D112 high output, 119dB(A) Alarm Sounder. Low current consumption and high SPL. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. Marine grade aluminium housing. Stainless steel fixings. Programmable version available. IP66. VdS, UL & cULs approved.

IS-D105-G
(6425)

E2S  IS-D105-G

E2S IS-D105 105dB(A) intrinsically safe Alarm Sounder. 49 alarm tones and 2 remotely selectable stages. 2 M20 entries. 24VDC. IP66. ATEX and IECEx approvals.

DB5_B024NR
(1569)

MEDC  DB5B024NR

MEDC DB5 Sounder (up to 103 dB(A)) with 26 output tones, Zone 0, Zone 1, and Zone 2 use, Intrinsically Safe (Exia), Weatherproof, IP65, designed with a high weatherproof rating to cope with the harsh environmental condition. -20C to +55C. ATEX, IECEx and CCC approvals also available.

Configure

$522.63 
E2xS112FDC024A1A1B
(4423)

E2S  E2xS112FDC024A1A1B

E2S E2xS112 Alarm Sounder/Horn 116dB(A). Suitable for all general signalling duties in the harshest of environments. PPS & ABS high impact housing. 24VDC, 115VAC or 230VAC Versions. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX and IECEx Approved.

MV121DC024G-UL
(3608)

E2S  MV121DC024G-UL

E2S MV121 Appello X User Recordable Alarm Sounder 126dB(A). Low current consumption. With robust and fire retardant IP66 & IP67 housing. Volume Control. 14-30VDC or 90-260VAC Versions. UL and cULs Approved.

E2XS121FDC024A1A1B
(4424)

E2S  E2XS121FDC024A1A1B

E2S E2xS121 Alarm Sounder/Horn 121dB(A). Suitable for all general signalling duties in the harshest of environments. PPS & ABS high impact housing. 24VDC. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX and IECEx Approved.

DB7PW012NR
(4186)

MEDC  DB7PW012NR

MEDC DB7 Sounder (up to 110 dB(A)) with 27 output tones, Weatherproof only version, IP66 and IP67, intended for use in potentially explosive atmospheres. -55C to + 70C.

Configure

$608.91 
D2XS1AC115CN1A1G
(4426)

E2S  D2XS1AC115CN1A1G

E2S D2xS1 Alarm Horn Sounder 116dB(A). Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for all haz loc applications. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

E2XS1FDC024CN1A1B
(6423)

E2S  E2XS1FDC024CN1A1B

E2S E2xS1F 116dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

DB7PBB012NR
(1610)

MEDC  DB7PBB012NR

MEDC DB7 Sounder (up to 110 dB(A)) with 27 output tones, Zone 0, Zone 1, and Zone 2 use, Intrinsically Safe (Exia), Weatherproof, IP66 and IP67, intended for use in potentially explosive atmospheres. -55C to + 70C. ATEX Approved Ex II 1G, BASEEFA Certified, EExia IIB T4. CUTR version also available.

Configure

$675.71 
MA2FDC024CN1A1G
(3607)

E2S  MA2FDC024CN1A1G

E2S MA2F Alarm Horn Sounder 123dB(A). High output. Robust and fire retardant IP66 & IP67 housing. Automatic synchronisation. M20 or 1/2"NPT cable entries. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. 64 alarm tone frequencies.

DB7PBC012NR
(4185)

MEDC  DB7PBC012NR

MEDC DB7 Sounder (up to 110 dB(A)) with 27 output tones, Zone 0, Zone 1, and Zone 2 use, Intrinsically Safe (Exia), Weatherproof, IP66 and IP67, intended for use in potentially explosive atmospheres. -55C to + 70C. ATEX Approved Ex II 1G, BASEEFA Certified, EExia IIC T4. CUTR version also available.

Configure

$738.20 
Page: 1 | 2 | 3 | 4 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.