Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (6736)

PROSENSE  PQD-5535

$612.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



PROSENSE PQD-5535 (1)
  • Overview
  • Features
  • Specs
  • Related
  • Literature

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Part# with Options:        PQD-5535
Price with Options:        612.00

Options:    

Gas
(1) Gas for Prosense PQD-XY35 & P-XY35 (2)
Relays
(2) Relays for Prosense PQD
IP66 Adaptor
(3) Stainless Steel Sensor Adaptor for Prosense PQD & P
No calibration port
Stainless Series Enclosure
(4) Stainless Series Enclosure for Prosense PQD
Remote Display
(5) Remote Display for Prosense PQD over RS-232, ATEX
SIL2
(6) SIL2 Certification for Prosense PQ Detectors by TUV Rheinland

  Availability 2 Weeks  ]

OLED Display

PROSENSE "PQD" Series fixed gas detectors are certified with ATEX/IECEx and SIL2.

Ex-proof Safety

The continuous measurement of toxic and explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Performance Approval

It complies with the measurement performance criteria in accordance with the IEC EN 60079-29-1 standard.

Functional Safety

Prosense promotes SIL approved products to reduce safety risks associated with increasingly complicated systems as malfunctioning equipment could pose a potential risk. PQ series has ongoing process for SIL-2.

Robust and Durable

SS316 stainless steel sensor head performs perfectly under harsh environmental conditions with the IP65/ IP66 protection class.

Accurate Readings

Pellistor, Electrochemical, PID, and Infrared sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog and Modbus RS485 RTU outputs are provided onboard to operate properly without any additional setup.

Easy Maintenance

PQD Series detectors allow sensor replacement with pre-calibrated sensor head thanks to the Procell technology.

OLED Display

The OLED screen can be easily read from any angle.

SAFELOG Data Logger

PQD Series records status up to 250 events. In case of sudden power cut, you can save the data thanks to the cell battery.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Pellistor-Saver Mode

Detectors power off the sensor in high gas concentration in order to properly secure the operational lifetime of pellistor sensor.

Auto Analog Signal Calibration and Monitoring

PQD Series detectors continuously check the analog output signal level to match the measurement level before promptly transferred to the panel. PQD Series adjusts the signal level in case of any deviation and generates a fault signal when the adjustment fails.

Zero Suppression

Adjusting, the detector can show a certain measurement level as 0 (zero) to avoid unnecessary concerns.

Simple External Equipment Control

Optional relay module enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm.

Continuous Self-Test

The detectors check itself continuously to make sure it operates perfectly and indicates a fault in case of any failure.

Adjustable Parameters

All parameters can be easily changed according to the application requirements or facility standards.

Remote Display

Depending on the application requirements, the screen can be placed separately.

Easy Status Recognition

Colored LEDs (green, yellow and red) provide additional alarm and status information.

Maintenance via Software

Prosense provides software to maintain your active system easily and calibrate the gas detectors properly via computer.

Applications
  • Oil&Gas
  • Petrochemical
  • Onshore/Offshore
  • Steel-Metal Industry
  • Chemical Industry
  • Process Industry
  • Gas Distribution Stations
  • Water Treatment Plants

Specifications PQD-XY35
Sensor Technology Pellistor
Output Signal 4-20mA and Modbus RS485
Sensor Warm-Up 60sec
Response Time(T90) <25sec
Accuracy %1
Operating Temperature -40°C ~ +70°C
Humidity 0~ 100%RH Non-Condensing
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Display 128x64 Graphic OLED
5 LED indicator for detector status
Event Logging Records alarm, fault and maintenance events up to 250 logs
Power Consumption Max. 4W
Relay Outputs 2 Alarms (Programmable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 3 x 1/2" NPT
IP Rating IP65/IP66
Junction Box Epoxy Painted Die-Cast Aluminum / 316 Stainless Steel
Sensor Head 316L Stainless Steel
Dimensions/Weight 196,96x145,99x112mm / 2100gr
ATEX Marking II 2G Ex db IIC T6 Gb
II 2G Ex mb db IIC T6 Gb
I M2 Ex db I Mb
Hazardous Class Zone 1 - Zone 2 - M2
Certificates ExVeritas 18 ATEX 0371X
IECEx EXV 18.0021X
FTZU 18 ATEX 0086
IEP12 ATEX 6118X
Optional SIL2
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
IEC EN 60079-29-1
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

  • ACCESSORIES > GAS DETECTORS P/PQ
    PK-K30T Prosense Teflon Calibration cup/cap for P, PQ and B Series gas detectors, tubing entry 4mm diameter tubing. Optional SS316 ..

  • CALIBRATION GAS > HYDROGEN
    CYL-90301910 Calibration Gas Hydrogen (H2), 50% LEL 2% vol Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • CALIBRATION GAS > METHANE
    CYL-90090227 Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • CALIBRATION GAS > PROPANE
    CYL-90095187 Calibration Gas Propane (C3H8) 50% LEL 1.1%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas) ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    S-DP4 Prosense S-DP4 gas control panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer . Optional Modbus RS485 output and Alarm/Fault Relays. Polycarbonate Hous ..

  • MULTI-POINT CONTROLLERS > 8-CHANNEL
    S-DP8 Prosense S-DP8 gas control panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Optional Modbus RS485 output and Alarm/Fault Relays. Polycarbonate Housi ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal

> LEL CATALYTIC BEAD :    34 Items found.
GD-2A
(650)

MACURCO  GD-2A

MACURCO Combustible Gas Detector low voltage all-electronic monitor engineered to detect heating type gases, including methane (natural gas) and propane(bottled gas). 12-24 VAC or VDC input. SPDT alarm and NC trouble relays. Listed to UL Standard 2075. CSFM Approved.



$112.17 
GD-2B
(2047)

MACURCO  GD-2B

Macurco GD-2B Gas Detector for combustibles (heating type gases). Low voltage and designed for connection to Fire Alarm/Burglary Control Panels. 9-32 VDC or 12-24 VAC input. Meets UL 2075 standard. Alarm, trouble relays and 85dB buzzer.



$112.17 
BTN-3042
(6723)

PROSENSE  BTN-3042

Prosense BTN-XY42 Gas Detector with Catalytic sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Pentane, nButane) with range 0-100% LEL. ABS plastic housing. 2 Alarms and 1 Fault Relays and optional Modbus RS485 RTU output. IP54.

Configure

$117.00 
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$162.00 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$207.00 
P-3012PEK
(6800)

PROSENSE  P-3012PEK

Prosense P-XY12PEK Gas Detector with Catalytic and Motion sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$252.00 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$342.50 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Pentane, Hexane and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$351.00 
P-5535
(6774)

PROSENSE  P-5535

Prosense P-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$351.00 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$410.80 
GD-6
(1234)

MACURCO  GD-6

MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$483.29 
GD-12
(3416)

MACURCO  GD-12

MACURCO GD-12 line voltage Gas Detector, controller and transducer for Combustibles (EX) 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$495.08 
G02-B030-000
(3014)

RAE  G02-B030-000

ToxiRAE Pro LEL PGM-1820 Personal Portable Monitor For Combustible Gases (0-100% LEL) and Vapors with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging. CSA, ATEX, IECEx and China Ex Approved. Wireless-capable option.

Configure

$514.29 
SPC3-3355-200US
(2911)

INTEC  SPC3-3355-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Methane, Methyl Ethyl Ketone, n-Butane, n-Octane, n-Pentane, Propane, Acetone, Jet A, JP8 and Toluene.

Configure

$611.40 
SPC3-3380-200US
(2910)

INTEC  SPC3-3380-200US

Intec Controls PolyGard SPC3-3300 Sigle-Point Gas Detector for Combustibles 0-100% LEL (Catalytic Bead), 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. Available gases: Ammonia, Ethylene, Ethyl Alcohol, Ethyl Acetate, Benzene, n-Hexane, n-Heptane, Hydrogen, Isopropyl Alcohol and Methanol.

Configure

$611.40 
PQD-3035
(6718)

PROSENSE  PQD-3035

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Pentane, Hexane and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$612.00 
2106B2310
(1640)

HONEYWELL  2106B2310

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Configure

$616.70 
GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$837.20 
GDS-48-1-71-06
(343)

GDS  GDS-48-1-71-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with Catalytic Bead for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit). 3-Wire Bridge Output. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others. CSA Certified for Div. 1 Explosion Proof.

Configure

$845.00 
EX-_GENL-100L-O
(6021)

MACURCO  EX-GENL-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Combustible Gases 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. CSA approvals for Class I Division 2. Optional calibration to Methane, Propane, Pentane, Methanol, Hydrogen, Ethylene, Acetone, Butanol, Butane, Benzene and other combustibles.

Configure

$935.00 
Page: 1 | 2 | All