Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (662)

HONEYWELL  SPXCDULNO1

DETECTORS / GAS DETECTORS
OXYGEN

$1,023.48     Availability: 3 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



HONEYWELL SPXCDULNO1 (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Literature

Honeywell XCD Sensepoint Gas Detector, Oxygen (O2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66 for oxygen (O2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 25%Vol. only UL/CSA Class I Division 1 or ATEX IECEx available.

Part# with Options:        SPXCDULNO1
Price with Options:        1,023.48

Options:    

Modbus RTU
(1) Honeywell XCD Transmitters
Enclosure
(2) Honeywell XCD Transmitters
Agency Approval
(3) Honeywell XCD Transmitters
Entry
(4) Conduit entry for Honeywell XCD detectors
Sunshade/Deluge Protection
(5) Honeywell XCD Transmitters
Custom Tag
(6) SSTAG Stainless Steel Custom Tag for Honeywell Gas Detectors

  Availability 3 Weeks  ]

XCD normal display (green) XCD Display in Fault/Warning (Yellow) XCD display in Alarm (Red)
Normal Fault/Warning Alarm
FEATURES

One-Stop Shop
  • Flammable (catalytic or infrared), toxic and oxygen versions available
  • New and retrofit applications
  • Suitable for indoor or outdoor use
  • Stainless steel or aluminium explosion-proof housing options
  • IP66 as standard
Proven and Reliable Sensor Technology
  • SurecellTM electrochemical sensors
  • Reflex® sensor health check
  • Poison immune infrared sensors
  • Poison resistant catalytic bead sensors
  • Long life sensors
Global Approvals
  • US and Latin America, European, Canadian and Asian
  • Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
  • User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
  • Fully configurable via magnetic switches
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance
  • MODBUS communications for remote diagnostics/configuration
Cost Effective
  • Common transmitter platform
  • Minimal training required
  • Reduced spares
  • Non-intrusive, one-man operation
  • Plug-in sensor replacement
  • MODBUS multi drop option offers cabling savings
Simple Installation
  • Plug-in display module removes to give access to terminal area
  • Integral mounting bracket
  • 2 x M20 or 3⁄4” NPT cable/conduit entries (certification dependent)
  • Removable plug/socket type terminal blocks for ease of wiring
  • Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
  • Remote sensor gassing kit
  • Duct mounting kit
  • Calibration gas flow housing
  • Collecting cone

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs

Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors, downtime is also reduced and on-going costs are minimized through the use of poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented SurecellTM toxic sensors and Reflex® sensor health check.

All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and Modbus.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or 3⁄4”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.

TYPICAL APPLICATIONS

  • Industrial manufacturing facilities
  • Power plants
  • Waste water facilities
  • Utilities
  • Food and beverage production
  • Refineries and chemical plants
  • Onshore oil and gas terminals
  • Production platforms
  • Exploration and drilling
Honeywell XCD detector components

1 Cover
2 Display module
3Terminal area
4 Blanking plug
5 Transmitter
6 Plug-in XCD sensor
7 Sensor retaining ring
8 Integral mounting plate
9 Weather protection assembly
10 Cable/conduit entry (x2)
11 Certification label

There are three different types of the XCD transmitter for use with three different families of sensors.

The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL, as well as Carbon Dioxide (CO2) in the range 0-2%Vol.

The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulfide, (H2S), Hydrogen (H2) and Nitrogen Dioxide (NO2).

The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors.

A transmitter can auto-recognize any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.

Sensepoint XCD uses three instantly recognizable ‘traffic light’ colors to indicate its status. The large tri-color backlit LCD is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.

Specifications
Gas Oxygen
Sensor Family O2
User Selectable Full Scale Range 25.0%Vol. only
Default Range 25.0%Vol.
Steps n/a
User Selectable Cal Gas Range 20.9%Vol. (Fixed)
Default Cal Point 20.9%Vol.
Response Time (T90) Secs <30
Accuracy <+/-0.5%Vol.
Min Operating Temperature -20°C / -4°F
Max Operating Temperature 55°C / 131°F
Default Alarm Point A1 19.5%Vol. ▲
Default Alarm Point A2 23.5%Vol. ▲

General Specifications
Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and Oxygen hazards. Incorporating a transmitter with local display and fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized
Communication RS485, MODBUS RTU
Construction
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: 316 stainless steel
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries UL\cUL versions: 2 x ¾"NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating; ATEX/IECEx versions: 2 x M20 cable entries
Environmental
IP Rating IP66 in accordance with EN60529:1992
Certified Temperature Range 40ºF to +149ºF (-40ºC to +65ºC)

Certification
US, Latin America, Canada UL/c-UL - Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40°C to +65°C
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
EMC CE: EN50270:2006 EN6100-6-4:2007
Performance UL508; CSA 22.2 No. 152 (flammable gasses, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors) “CCCF” Shenyang for Flammable (fire dept approval)

Honeywell Sensepoint XCD Part Number

Honeywell Sensepoint XCD Option Matrix

Export Info
Made inSouth Korea
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > HONEYWELL XCD
    SPXCDXSO1SS Replacement Sensor Cartridge for Oxygen (O2) XCD Detector 25.0%/Vol ..

  • ACCESSORIES > HONEYWELL XCD
    S3KCAL Calibration Cap/Cup for Honeywell Sensepoint XCD Sensors. ..

  • ACCESSORIES > HONEYWELL XCD
    SPXCDCC Collecting cone for use with lighter than air gases for Honeywell Sensepoint XCD Sensors. ..

  • ACCESSORIES > HONEYWELL XCD
    SPXCDDMK Duct mounting kit for Honeywell Sensepoint XCD Sensors. ..

  • ACCESSORIES > HONEYWELL XCD
    SPXCDHMANEN Hard Copy Manual in English for Honeywell Sensepoint XCD Sensors. ..

  • ACCESSORIES > HONEYWELL XCD
    SPXCDMTBR Mounting bracket for Honeywell Sensepoint XCD Sensors. Includes bolts, nuts and brackets ..

  • ACCESSORIES > HONEYWELL XCD
    SPXCDSDP Sunshade/Deluge Protection for Honeywell Sensepoint XCD Sensors. ..

  • MULTI-POINT CONTROLLERS > 8-CHANNEL
    TPPLBDWA2NNNNNN Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 16 gas detection channels (w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, Built-in sounder, 3 alarm relay outputs, datalo ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > OXYGEN :    43 Items found.
M014-0003-000
(6334)

MPOWER  M014-0003-000

mPower UNI 321 Disposable Single Gas Detector for detection of Oxygen (O2) 0.1%-30%. Up to 36 months of live. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$100.80 
BWC2-X
(4267)

BW  BWC2-X

BW Clip portable gas detector 2 year maintenance free for Oxygen O2. Low alarm set at 19.5%, High alarm set 23.5%. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.



$117.00 
M001-0032-000
(6005)

MPOWER  M001-0032-000

mPower UNI MP100 Portable Single Gas Detector for detection of Oxygen (O2) 0-25% or 0-30% vol. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.

Configure

$188.00 
BWC2R-X
(5151)

BW  BWC2R-X

BW Clip Real Time portable gas detector with 2 year maintenance free for Oxygen (O2). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

Configure

$191.40 
10092523
(2650)

MSA  10092523

MSA ALTAIR Portable Single-gas Detector for Oxygen, alarms at 19.5% Vol. and 23% Vol. (O2) coupled with LED/audible/vibrating alarms. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class 1, Division 1, Groups A, B, C and D. 2 years.



$271.32 
BWS_-XL-Y
(6392)

BW  BWS-XL-Y

Honeywell BW Solo Serviceable Single-gas Detector for Oxygen (O2) 0-30% v/v. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$338.80 
OX-6
(4089)

MACURCO  OX-6

MACURCO OX-6 low voltage Gas Detector, Controller and Transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$348.49 
OX-12
(4090)

MACURCO  OX-12

MACURCO OX-12 line voltage Gas Detector, controller and transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$356.99 
GAXT-X-DL-2
(479)

BW  GAXT-X-DL-2

BW GasAlertExtreme Portable detector with gas concentration readout for Oxygen O2 0-30%

Configure

$370.48 
10074137
(1638)

MSA  10074137

MSA ALTAIR Pro Portable Single-gas Detector for Oxygen (O2) 0-25% Vol. coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 19.50%, High 23.00%



$431.14 
G02-BE10-100
(3015)

RAE  G02-BE10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Oxygen (O2) 0-30% vol. with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$449.35 
SPSTAXO1
(1476)

HONEYWELL  SPSTAXO1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Oxygen (O2) 0-25% VOL complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$452.09 
6302-0003
(6232)

BACHARACH  6302-0003

Bacharach MGS-410 Gas Detector Transmitter with electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. RS485 MODBUS RTU output, audible & visual alarms. IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$477.00 
6302-1003
(6242)

BACHARACH  6302-1003

Bacharach MGS-450 Gas Detector Transmitter with electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, audible & visual alarms. IP41 or IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$513.00 
SPC3-1195-200US
(2909)

INTEC  SPC3-1195-200US

Intec Controls PolyGard SPC3-1195 Sigle-Point Gas Detector for Oxygen (O2) 0-25% Vol, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified.



$610.48 
6302-4003
(6252)

BACHARACH  6302-4003

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, audible & visual alarms. IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$634.50 
XT-X000-Y-NA
(578)

BW  XT-X000-Y-NA

GasAlertMax XT 4-Gas Detector for O2 (Oxygen). Monitors up to 4 gas hazards for confined space entry and remote sampling.

Configure

$636.40 
GG-O2-C0
(2968)

CALIBRATION TECHNOLOGIES  GG-O2-C0

CTI GasGuard O2 Oxygen Electrochemical Sensor (15-25% or 0-25%) for gas leak detection in food air quality monitoring, refrigeration systems, confined space and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$661.20 
364-455-01-365-251-11
(6157)

DELPHIAN  364-455-01-365-251-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Oxygen (O2) 0-21% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$681.60 
GDS-49-1-10-04
(124)

GDS  GDS-49-1-10-04

GDS GDS-49 Remote Gas Detector Transmitter with Stainless steel sensor head configured for Oxygen (O2) with range 0-25%, Explosion Proof (XP). 2-Wire 4-20 mA transmitter.

Configure

$710.00 
Page: 1 | 2 | 3 | All