NOTIFIER   HPF24S6

SKU# (6601)
NOTIFIER HPF24S6
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier HPF24S6(C/E) (6 amp) or HPF24S8(C/E) (8 amp) Remote Fire Alarm Power Supply with battery charger for 12 or 24 volt fire alarm control panels (FACP). 4 configurable outputs. UL, ULC and NFPA listed. *** Phased Out Replaced by HPF-PS6***

Inquiry

The HPF24S6(C/E) and HPF24S8(C/E) are compact, cost-effective, 6-amp or 8-amp remote power supplies with battery charger.

They may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The supply provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. They also contains a battery charger capable of charging up to 18 Amp Hour batteries.

FEATURES AND BENEFITS
  • Extends and supports power for additional fire alarm devices
  • Instantaneous switchover to standby battery (if equipped) when AC fails, maintaining power to all attached devices without intervention
  • Strobe signal “passes through” allowing syncing of large systems
  • LED lights for quick and easy diagnosis, troubleshooting, and status indication
  • Two outputs can be used for constant power devices such as door holders (power drops upon alarm)
  • Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power)
  • UL Listed NAC Synchronization using System Sensor®, Wheelock®, or Gentex® (Commander Series) appliances
  • Cascade up to 10 power supplies (four with Gentex) with strobe timing maintained
  • Operates as a sync follower or a sync generator (default)
  • Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode])
  • Configured to internally house addressable SLC control module for alarm activation
  • Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits
  • 6.0A or 8A (depending on model) full load output (3.0 A maximum per circuit) in NAC expander mode (UL 864)
  • 4.0A or 6.0A continuous output in stand-alone mode (UL 1481)
  • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two
  • Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power
  • Power-limiting technology meets UL power-limiting requirements
  • Form-C normally-closed trouble relay
  • Fully supervised power supply, battery and Notification Appliance Circuits
  • Selectable earth fault detection
  • AC trouble report selectable for immediate or 8 hour delay
  • Requires input trigger voltage of 9.0 - 32 VDC
  • Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D)
  • Includes integral battery charger capable of charging up to 18 AH batteries; cabinet capable of housing 7.0 AH batteries
  • Battery charger may be disabled via dip switch for applications requiring larger batteries
  • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire
  • Power-limiting technology meets UL power-limiting requirements
  • Form-C normally-closed trouble relay
  • Fully supervised power supply, battery and Notification Appliance Circuits
  • Selectable earth fault detection
  • AC trouble report selectable for immediate or 8 hour delay
  • Requires input trigger voltage of 9.0 - 32 VDC
  • Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D)
  • Includes integral battery charger capable of charging up to 18 AH batteries; cabinet capable of housing 7.0 AH batteries
  • Battery charger may be disabled via dip switch for applications requiring larger batteries
  • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire
STANDARDS AND CODES
  • NFPA 72 National Fire Alarm Code
  • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode)
  • UL 1481 Power Supplies for Fire Alarm Systems (standalone mode)
  • CAN/ULC-S527-99
Listings

Listings and approvals below apply to the HPF24S6 and HPF24S8. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S6677
  • CAN/ULC Listed: S6677
  • CSFM: 7315-1637:0102
  • FM Approved

Specifications
Primary (AC) Power:HPF24S6/8(C): 120 VAC 60 Hz, 3.2 A maximum
HPF24S6/8E: 220/240 VAC, 50 Hz, 1.6 A maximum
Wire size: minimum 14 AWG (2.0 mm2) with 600V insulation
Control Input Circuit:Trigger Input Voltage: 9.0 to 32 VDC
Trigger Current: 2.0 mA (16 - 32 V)
(per input) 1.0 mA (9 - 16 V)
Trouble Contact Rating:5.0 A at 24 VDC
Auxiliary Power Output:Special Application Power - 500 mA maximum
Output Circuits:+24 VDC filtered, regulated
3.0 A maximum for any one circuit
4.0 A maximum total continuous current for all outputs (Stand-alone mode) for the HPF24S6 and 6A for the HPF24S8
6A or 8A (depending on model) maximum total short-term current for all outputs (NAC Expander mode)
Secondary Power (Battery) Charging Circuit:Supports lead-acid batteries only
Float-charge voltage: 27.6 VDC
Maximum current charge: 1.5 A
Maximum Battery capacity: 18 AH
> NOTIFIER :    43 Items found.
LCM-320
(6871)

NOTIFIER  LCM-320

Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.