Bw Bws1-z-y | Hydrogen Cyanide | Gas Detectors (portable) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

BW   BWS1-Z-Y

BW BWS1-Z-Y
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

BWS1-Z-Y   
Please Email us your request for quote   

Wireless
Housing

   9 Weeks  ]
2 Variants of base SKU
The next-generation single-gas detector that helps you reduce cost, ensure compliance and know your workers are protected.

Honeywell BW Solo has everything you expect — plus additional features to make your compliance easier and more cost-effective than ever. All with a reliable life span, one-button operation and small, lightweight profile. Honeywell BW Solo is:

  • The easiest single-gas detector to service, with no need to take it apart to replace sensors, batteries and sensor filters. That means long life and low cost.
  • Complete with an extensive selection of sensor options. Count on comprehensive detection, whether you’re monitoring for common or exotic hazards.
  • The first single-gas detector with the 1-Series sensor for CO, H2S and O2. That means high accuracy, lower costs and faster sensor response time for the gases you monitor most often.
  • Compatible with IntelliDoX. Save time and centralize data with automated bump testing, calibration and instrument management. Use IntelliDoX docking stations with Honeywell Safety Suite Device Configurator software.
FEATURES & BENEFITS For even more time-saving convenience — plus remote visibility on alarms — choose the wireless version. And manage it from your smartphone.

Pair the wireless Honeywell BW Solo with our Safety Communicator mobile app and detector readings are sent instantly to Honeywell’s real-time monitoring software. Access it from any device with an internet connection, and get remote visibility on worker safety and location.

You can also use the wireless Honeywell BW Solo to share gas data with the desktop software — no dock required.

Other Honeywell BW Solo features:
  • Option to activate IntelliFlashTM or non-compliance flash
  • Ability to assign detectors to workers and locations
  • Easy-to-read display for multiple languages
  • Data logging with rolling 24-hour peak reading

Honeywell BWTM Solo Technical Specifications
SIZE 2.7 x 2.6 x 1.4 in. / 7.0 x 6.7x 3.6 cm (1-Series sensor models)
2.7 x 2.6 x 1.6 in. / 7.0 x 6.7x 4.1 cm (4-Series sensor models)
WEIGHT 3.6 to 4.1 oz. / 103 to 116 g, depending on installed sensor
HUMIDITY 5 - 95% RH (non-condensing)
INGRESS PROTECTION IP66/68
ALARMS AND TYPE Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, non-compliance
SELF-TEST Sensor integrity, circuitry, battery and audible/visual alarms on activation; battery (continuous)
TYPICAL BATTERY LIFE 12 months (6 months for 1-Series O 2 )
CONNECTED WORKER BluetoothTM Low Energy (BLE) – Ability to connect to Honeywell’s Safety Communicator App
USER OPTIONS Reset TWA, STEL and Peak readings
Change High, Low, TWA and STEL alarm setpoints
Latching alarms
Enable IntelliFlash and non-compliance indicators
Set calibration and/or bump test reminders
Assign worker and location assignments
Language select: English, French, Spanish, German, Italian, Russian, Japanese, Chinese, Korean, Portuguese, Dutch
CERTIFICATIONS AND APPROVALS CSA: Class I, Division 1, Groups A, B, C, D T4
Class I, Zone 0, AEx/Ex ia IIC T4 Ga -40°C≤ Tamb ≤ 60°C
ATEX: Sira 19ATEX2004
X 0518 g II 1G Ex ia IIC T4 Ga -40°C≤ Tamb ≤ 60°C
g I M1 Ex ia I Ma -40°C≤ Tamb ≤ 60°C
IECEx: IECEx SIR 19.0004
Ex ia IIC T4 Ga / Ex ia I Ma -40°C≤ Tamb ≤ 60°C
FCC ID: SU3BWS1
IC: 20969-BWS1
RED: RE-D Directive 2014/53/EU
WARRANTY 3 years for 1-Series sensors and 1-Series detectors (excluding battery)
2 years for 4-Series sensors and 4-Series detectors (excluding battery)
1 year for H2 , NH3 , Cl2 , O3 , ClO2 sensors

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    2 Items found.
(6397)

BW  DX-NEST-SOLO

BW IntelliDoX Nest for BW Solo Gas Detector



 
DX-SOLO
(6396)

BW  DX-SOLO

BW IntelliDoX automated instrument management system for BW Solo. 12V. Provides bump testing, calibration, configuration, and record-keeping support. Infrared communication. Ethernet and USB port. Includes 2GB internal data storage.

> HYDROGEN CYANIDE :    15 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$358.40 
364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

P-7534
(6789)

PROSENSE  P-7534

Prosense P-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
1100ALD-109020/30P-L0
(6912)

RC SYSTEMS  1100ALD-109020/30P-L0

RC Systems SenSmart 1100 gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
PQN-7534-1/2
(6962)

PROSENSE  PQN-7534-1/2

Prosense PQN-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,338.48 
PQD-7534-1/2
(6750)

PROSENSE  PQD-7534-1/2

Prosense PQD-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,492.92 
41001AL-0-1020/0030P/L0
(7165)

RC SYSTEMS  41001AL-0-1020/0030P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1020/30P/L0
(7128)

RC SYSTEMS  51001AL-0-1020/30P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2100AL-0-9020/30P/L0
(127)

RC SYSTEMS  2100AL-0-9020/30P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-30ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,899.32 
31001AL-0-9020/30P/L0
(5783)

RC SYSTEMS  31001AL-0-9020/30P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical Smart Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

6100AL1-0-1020/0030P
(7007)

RC SYSTEMS  6100AL1-0-1020/0030P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,391.48 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.