DETCON  961-500026-100G

DETCON 961-500026-100G (1)
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE

Detcon DM-102-NH3 Electrochemical Ammonia (NH3) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

Part# with Options:        961-500026-100G
Price with Options:        Please Email us your request for quote   

Options:    

Terminal Material
(1) Terminal Material for Detcon DM-100
Approval
(2) Approval for Detcon DM-100
Alarm Relay Module
(3) Remote Control/Alarm Relay module 975-70000A for Detcon

  Availability 3 Weeks  ]



Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a 3⁄4 inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.

Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

Features
  • XP-intrinsically Safe
  • Class I, Div. 1, Groups B, C & D
  • 2 Wire Loop powered
  • Field Replaceable Electrochemical Sensor
  • Non-intrusive Magnetic Interface
  • Built-in Diagnostics
  • Fully Encapsulated ITM Electronics
  • Electropolished 316SS Construction ITM
  • Quick Thread Release (for sensor replacement)
  • Integral Calibration Port
Applications
  • Oil and Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Waste Water Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type
Span Drift<5% signal loss per year (in first 2 years)
OutputsLinear 4-20 mA DC
Electrical ClassificationExplosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Measurement Range0-100 ppm, Other ranges available
Safety ApprovalsCCSAUS
Sensor Life/WarrantyPlug-in cell - 2 years (2 years expected life) ; Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-40 to 122oF/-40 to 50oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range0% to 99% RH non-condensing (continuous)
0%-100% RH (intermittent)
Operating Pressure RangeAtmospheric ±10%
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5" (140mm) center to center
Weight2 lbs; 0.907 kg (sensor only)
6 lbs; 2.72 kg (w/aluminum j-box)
9 lbs; 4.08 kg (w/stainless steel j-box)
Electrical Specifications
Power Input11 - 30 VDC
Power ConsumptionNormal operation = 30mA @ 24V (<0.75 watt)
Maximum = 50mA @ 24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)< br/> 0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Status IndicatorsOptional 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
 


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    2 Items found.
943-000006-132
(6566)

DETCON  943-000006-132

Detcon Calibration adapter/hood for series FP, IR, DM, O2



 
371-444400-0100
(6200)

DETCON  371-444400-0100

Detcon Carbon Monoxide (CO) plug-in sensor for DM-100-CO

> AMMONIA :    47 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$313.20 
PC3-4824
(6803)

PROSENSE  PC3-4824

Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$346.50 
BWS_-A_-Y
(6382)

BW  BWS-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

6302-0026
(6233)

BACHARACH  6302-0026

Bacharach MGS-410 Gas Detector Transmitter with electrochemical or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-30000ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$544.50 
P-4834
(6778)

PROSENSE  P-4834

Prosense P-4834 Gas Detector with Electrochemical sensor for Amonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$577.50 
6302-1026
(6243)

BACHARACH  6302-1026

Bacharach MGS-450 Gas Detector Transmitter with electrochemical or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-30000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$603.00 
TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$639.00 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$642.00 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$700.80 
6302-4026
(6253)

BACHARACH  6302-4026

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-30000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$740.70 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$792.47 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$866.25 
1100ALD-109012/0300P
(6908)

RC SYSTEMS  1100ALD-109012/0300P

RC Systems SenSmart 1100 gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 1 (Explosion Proof).

Configure

$914.78 
PQD-4834-1/2
(6739)

PROSENSE  PQD-4834-1/2

Prosense PQD-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$981.75 
6600-8019
(6269)

BACHARACH  6600-8019

Bacharach MGS-550 Industrial Refrigerant Gas Detector with electrochemical, catalytic or semiconductor sensor for Ammonia (NH3) 0-100ppm to 0-10000ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals.

Configure

$983.70 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$985.32 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$1,041.95 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,082.90 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,119.30 
LBW-50-RLV-115-SS
(914)

COOL AIR  LBW-50-RLV-115-SS

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$1,132.95 