  • Overview
  • Benefits
  • Specs
  • Literature

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Part# with Options:        364-455-01-365-790-11
Price with Options:        897.60

Options:    

Remote Display
(1) External Display Module for Delphian Gaz Tell IR/EC via RS-485
Alarm Relays
(2) Simple Local Alarm Module for Delphian Gaz Tell IR
Communications Module
(3) Communications Module for Delphian Gaz Tell IR and Determinator
Mounting Options
(4) Mounting Options for Delphian GazTell Electrochemical
Sensor Adaptors
(5) Adaptors for Delphian GazTell Electrochemical
Splash Guard
(6) Splash Guard for Delphian GazTell

  Availability 2 Days  ]

Hassle free safety:
  • Simple to use and install
  • Shock & vibration resistant
  • Low power consumption
  • Checks itself every second
  • Plain English displays
  • Tough
  • Reliable
  • Affordable
  • Accurate
THE DETECTOR HEAD

The GazTell detector head for electrochemical cells can be used alone or with the optional modules.

  • The small size (5”L x 2”W) makes it inconspicuous and allows placement in tight areas.
  • User-friendly, alpha-numeric LED display with understandable instructions and prompts.
  • Automatically recognizes the sensor cell with no configuration necessary.
  • Scrolls gas type every few seconds.
  • Low maintenance and low cost of ownership. The detector head logs and will display the last time it was calibrated.
  • Connects directly to conduit eliminating the need for expensive and bulky junction boxes.
  • Smart Sensor saves operator time and money. The sensor knows the highest reading since last calibration, the number of days since last calibration, how long the detector head has been in service, the percentage of life remaining in the sensor and highest/lowest temperatures observed during operation. It checks itself and its vital functions continuously.
  • Power consumption is very low. Even at its maximum power consumption (with the display at its brightest), the detector head uses only 77mA @ 24VDC.
OPTIONAL SLAM
Remote Relay Module
  • Set alarm levels without software, using simple jumper selection.
  • The module can be placed anywhere relays are needed.
  • Flexible design allows the relays to be placed next to the functions they operate.
  • The relay module has robust relays rated at 6 amp@120 volt relays for Fail, Low and High Alarms, so auxiliary relays are often not needed. Alarm relays can be latching or non-latching, energized or de-energized, normally open or closed. A 5 second alarm delay can be turned on to avoid false alarms.
  • FM Approvals tested the SLAM module for operation at -4 oF to 140 oF (-20 oC to +60 oC).
OPTIONAL EXMO
Remote Display Module

The EXMO communicates directly with the detector head and mimics its display. If the detector head is located remotely high or low, or in a difficult-to-calibrate place, locating the EXMO in an accessible position gives immediate access to the detector head’s sensor. It displays everything the detector head displays. It gives control via bi-directional RS-485 communication.

Remote calibration has never been so easy.

The small extension module has the same alpha numeric LED displays and color coded operation as the remotely placed detector head.

  • Check the sensor before entering a dangerous area.
  • Take the sensor online or offline
  • Calibrate
  • Cancel calibration

SPECIFICATIONS
DimensionsDetector Head: 5"L x 2"W
EXMO, SLAM & COMO: (each) 6"L x 3.5"W x 2"H
Shipping Weight Detector Head: .875 lbs (.4 kg)
EXMO, SLAM & COMO: (each) 1.25 lbs (.6 kg)
Power: Detector Head: 77 mA max
EXMO: 16mA max
SLAM: 56 mA max
COMO: 35 mA max
Operating Voltage Nominally 12-42 VDC
Output Signal Range 4-20mA or 1-5 mA (user selectable, 4 - 20mA is default). Modbus RTU available as an option.
Output is linear and proportional to the gas scale.
Load (maximum resistance) 300 Ohms
Measurement Ranges ppm according to toxic gas electrochemical cell and % by volume for oxygen.
Temperature Range Cell Storage: +32 oF (0 oC) to +68 oF (+20 oC)
The detector head: (depending upon cell installed)
-20 oC (-4 oF) to +70 oC (+158 oF)
The EXMO/SLAM/COMO:
-20 oC (-4 oF) to +60 oC (+140 oF)
Pressure The operating pressure range for toxic cells is normally ambient +/-10%
Mean Time Between Failures (MTBF@70F) 8 years (electronics)
SLAM Relays 6 amps@120 volts
SLAM Response Time Less than a second from the time the detector head sees sufficient gas to trigger an alarm to the relay operating.
EXMO Response Time Less than a second from the time the detector head sees gas to the EXMO displaying that gas concentration.
Detector Head RFI/EMI Immunity Less than 1% of full scale change with 5w transceiver keyed within three feet. RFI/EMI Protection complies with EN50270, EN61000-6-4, ISA/IEC 6001-4-3
Area Hazard Classification: Class I, Divisions 1 & 2, Groups C, D
SIL (Safety Integrity Level) SIL 2
Warranty Detector Head, SLAM, EXMO and COMO: two years from date of shipment.
Cell: one year from date of shipment.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HYDROGEN CYANIDE :    20 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$348.00 
BWS_-Z-Y
(6388)

BW  BWS-Z-Y

BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$399.50 
0401075
(6487)

DEGA  0401075

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Hydrogen cyanide (HCN) with range 0-100ppm. 4-20mA 3-Wire and RS-485 outputs. IP54.



$420.33 
0402082
(6519)

DEGA  0402082

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Hydrogen Cyanide (HCN) with range 0-100ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$439.88 
0407223
(6549)

DEGA  0407223

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Hydrogen Cyanide (HCN) with range 0-100ppm. Designed for explosive environments. 4-20mA 3-Wire and RS-485 (Dega/Modbus) outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$498.53 
G02-B710-100
(3022)

RAE  G02-B710-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen Cyanide (HCN) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$511.10 
10076729
(1660)

MSA  10076729

MSA ALTAIR Pro Portable Single-gas Detector for Hydrogen Cyanide (HCN) 0-30 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 4.7 ppm, High 10 ppm, STEL 10 ppm, TWA 4.7 ppm



$568.60 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical "Smart" Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

GM/EC-01-16-12
(127)

GDS  GM/EC-01-16-12

GDS GASMAX/EC 2-Wire Gas Detector with backlit LCD display and local stainless steel sensor head explosion proof (XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter.

Configure

$1,375.00 
ITRANS2-1940000
(6289)

OLDHAM  ITRANS2-1940000

Oldham iTrans 2 Fixed Gas Detector with electrochemical smart sensor for Hydrogen Cyanide (HCN) 0.2-30 ppm. 4-20mA optional RS-485 Modbus/HART and 3 alarm relay outputs. Explosion-proof NEMA 4X Enclosure. IP66. CSA, ATEX and IECEx Approvals.

S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, 0-30ppm

Configure

$1,422.84 
EX-HCN-50P-O
(6027)

MACURCO  EX-HCN-50P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Cyanide (HCN) 0-50ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,467.89 
GMII-01-016-12/00-000-00/0-0
(140)

GDS  GMII-01-016-12/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,545.00 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,747.41 
GM/ECx-03-16-12-1-0900
(1814)

GDS  GM/ECx-03-16-12-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$1,925.00 
GMCX-01-16-12/00-00-00/0
(3290)

GDS  GMCX-01-16-12/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,040.00 
GMIIx-03-016-12/00-000-00/1-0900
(1837)

GDS  GMIIx-03-016-12/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,120.90 
GM/TX/01-16-12/00-00-00/1-0900
(3426)

GDS  GM/TX/01-16-12/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,165.00 
ITR2SA-1940000
(6305)

OLDHAM  ITR2SA-1940000

Oldham iTrans 2 Stand-Alone Gas Detector with electrochemical smart sensor for Hydrogen Cyanide (HCN) 0.2-30 ppm. 4-20mA. NEMA 4X/IP66 Enclosure to be installed in safe area only (Non-Explosion Proof, no relays nor Modbus/HART available)