Detcon DM-700-C2H4 Electrochemical "Smart" Ethylene (C2H4) 0-100 ppm or 0-200 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Part# with Options:        967-12ED90-100
Price with Options:        Please Email us your request for quote   

Options:    

Junction Box
(1) Junction Box for Detcon DM-700
Options
(2) Options for Detcon DM-700
Range
(3) Range for Detcon DM-100/700-C2H4 Ethylene
Integration Modules
(4) Integration Modules for Detcon Series 700
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
Mounting Options
(5) Mounting Options for Detcon Series 700
Additional Modules
(6) Additional Modules for Detcon Series 700

  Availability 2 Weeks  ]

Detcon Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty.

Features Failsafe User-Friendly Interface
  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics
Environmentally Bulletproof
  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Applications
  • Oil & Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Wastewater Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
3-electrode electrochemical cell
Plug-in field replaceable Type
Measurement Range0-100 ppm
Accuracy/Repeatability±2% FS
Response/Clearing TimeT90≤140 seconds
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical ClassificationExplosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Class I, Zone 1, Group IIC
ATEX
II 2 G Ex d ib IIB + H2 T4 GB
Ingress ProtectionNEMA 4X, IP66
Safety ApprovalsCCSAUS
ATEX
CE Marking
SIL2 Certified to IEC 61508
Environmental Specifications
Operating Temperature Range-4 to 122oF/-20 to 50oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range15-90% RH non-condensing
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mechanical Connection:
Mounting holes (J-box) 5.5"; 140mm center to center
Weight2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input11-30 VDC
Power ConsumptionNormal operation = 30mA @24V (<0.75 watt)
Maximum = 50mA @24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
RFI/EMI ProtectionComplies with EN50270
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate (optional)9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan
Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

  • ASSEMBLY > DETCON
    S927-555500-100 Detcon DM-700-EC Electrochemical Universal ITM (Intelligent Transmitter Module) Spare Part for SO2, C2H2, AsH3, Br2, C4H6, CO, CL2, CLO2, B2H6, C2H5OH, C2H5SH, C2H4, C2H4O, F2, CH2O, H2, HBr,m HC ..
  • SENSORS (REPLACEMENT) > DETCON
    377-12ED01-100 Detcon Ethylene (C2H4) plug-in sensor for DM-700-C2H4 ..

  • CALIBRATION > DETCON
    943-000006-132 Detcon Calibration adapter/hood for series FP, IR, DM, O2 ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ETHYLENE :    10 Items found.
6600-8075
(6275)

BACHARACH  6600-8075

Bacharach MGS-550 Industrial Refrigerant Gas Detector with semiconductor sensor for Ethylene (C2H4) 0-2,000 ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals.

Configure

$566.10 
20100014
(6485)

DEGA  20100014

DEGA NB III Gas Detection Transmitter with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-1500ppm. RS-485 and optional 4-20mA 3-Wire outputs. IP54.

Configure

$645.12 
30100008
(6514)

DEGA  30100008

DEGA NS II Gas Detection Transmitter with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-200ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. IP54 (Optional IP66). ATEX Zone 2.

Configure

$737.28 
20100108
(6664)

DEGA  20100108

DEGA NB III LCD Gas Detection Transmitter with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-1500ppm. RS-485 and optional 4-20mA or 3 relay outputs. LCD display. IP54. SIL.

Configure

$829.44 
30100097
(6540)

DEGA  30100097

DEGA NS II LCD RE Gas Detector with Electrochemical Sensor for Ethylene (C2H4) with range 0-10ppm to 0-1500ppm. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$921.60 
EX-C2H4-100L-O
(6020)

MACURCO  EX-C2H4-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Ethylene (C2H4) 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$935.00 
30100172
(6541)

DEGA  30100172

DEGA NS II LCD RE Gas Detector with Infrared Sensor for Ethylene (C2H4) with range 0-100% LEL. Designed for explosive environments. RS-485 (Dega/Modbus) and optional 4-20mA 3-Wire outputs. 4 relays. LCD Display. IP54 (Optional IP66). ATEX Zone 2.

Configure

$1,013.76 
961-ED0026-100G
(6357)

DETCON  961-ED0026-100G

Detcon DM-100-C2H4 Electrochemical Ethylene (C2H4) 0-100ppm or 0-200ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2108N4101N
(1967)

HONEYWELL  2108N4101N

Honeywell Ethylene Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for LEL, 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Ethylene calibration with dust barrier, weather housing, deluge/heat shade, configured as current source output. Optional remote gassing cell.

Configure

$1,686.39 
2108N5101N
(1968)

HONEYWELL  2108N5101N

Honeywell Ethylene Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for LEL. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Ethylene calibration, for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output

Configure

$1,969.63