Detcon PI-700 Universal "Smart" Gas Sensor with Photo Ionization Detector (PID) technology for VOC 0-10ppm to 0-5000ppm. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Built-in numeric display. Water-Proof, Corrosion-Proof and Vibration-Proof. NEMA4X. IP66. CSA (Class I Div 1) and ATEX Approvals.

Part# with Options:        967-P15520-010
Price with Options:        Please Email us your request for quote   

Options:    

Junction Box
(1) Junction Box for Detcon PI-700
Options
(2) Options for Detcon PI-700
Integration Modules
(3) Integration Modules for Detcon Series 700
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
Mounting Options
(4) Mounting Options for Detcon Series 700
Additional Modules
(5) Additional Modules for Detcon Series 700

  Availability 2 Weeks  ]

Detcon Model PI-700 is a non-intrusive “Smart” sensor that use photo-ionization detector technology to monitor VOC gases over ranges from 0-10 ppm to 0-5,000 ppm. There is also a special 0-500 ppb version available. In the PI-700 sensor design, Detcon has successfully converted the sensitive laboratory style PID technology into a rugged, environmentally insensitive, and long-life industrial gas sensor. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The PI-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model PI-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model PI-700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s PID sensors have a long shelf life and are supported by an industry leading warranty.

Features Failsafe User-Friendly Interface
  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics
Environmentally Bulletproof
  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Applications
  • Pharmaceutical industry
  • Power plants
  • Chemical industry
  • Air quality
  • Refineries and petrochemical plants
  • Solvent recovery systems
  • Waste water treatment plants
  • Marine and off-shore oil wells
  • Pulp and paper industry
  • Painting and coating operations

System Specifications
Sensor TypeContinuous diffusion/adsorption
Photo Ionization Detector (PID)
Plug-in replaceable intelligent type (with replacement lamp)
Sensor Life 2 years typical
Measurement RangeGas Dependent, ranges as low as 0-10 ppm or as high as 0-5,000ppm (consult Detcon) Special Low Range 0-500 ppb
Accuracy/Repeatability±10% of reading or ±2% of range (greater of )
Response TimeT50 <30 seconds; T90 <60 seconds
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical ClassificationExplosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -20°C to +50°C)
Class I, Zone 1, Group IIB+H2
ATEX
II 2 G Ex d ib IIC T4 Gb (Tamb = -20°C to +50°C)
Ingress ProtectionNEMA 4X, IP66
Safety ApprovalscCSAus
ATEX
CE Marking
WarrantyPLUG-IN DETECTOR - 1 YEAR
TRANSMITTER - 2 YEARS
Environmental Specifications
Operating Temperature Range-4°F to +122°F; -20°C to +50°C
Storage Temperature Range-4°F to +122°F; -20°C to +50°C
Operating Humidity Range0-100% RH non-condensing
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5"; 140mm center to center
Weight2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input11-30 VDC
Power ConsumptionMaximum = 65mA (1.6 watts)
Inrush Current1.67A @ 24V
RFI/EMI ProtectionComplies with EN50270
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan
Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Zero, Missing Sensor, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair shielded cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity

  • SENSORS (REPLACEMENT) > DETCON
    377-P10000-010 Detcon Photo Ionization plug-in sensor for PI-700-10 (0-10ppm)..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > VOC PID :    15 Items found.
GDS-48-1-61-06
(347)

GDS  GDS-48-1-61-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with Photoionization Detector (PID) for VOC (Volatile Organic Compounds). 3-Wire Bridge Output. CSA Certified for Div. 1 Explosion Proof.

Configure

$1,695.00 
G02-B000-000
(3012)

RAE  G02-B000-000

ToxiRAE Pro PID PGM-1800 Personal portable Monitor For Volatile Organic Compounds (Detects over 300 VOCs) with replaceable sensors, fan, filter and battery. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Rechargeable Li-ion battery, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. Wireless-capable option.

Configure

$1,888.60 
TMII-00-00-00/48-61-05/0-0
(1670)

GDS  TMII-00-00-00/48-61-05/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

Configure

$2,115.00 
GMII-00-000-00/01-061-05/0-0
(609)

GDS  GMII-00-000-00/01-061-05/0-0

GDS GASMAX II PID 3-Wire Gas Detector with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$2,445.00 
PTLSLBMR-0000
(5956)

ION SCIENCE  PTLSLBMR-0000

Ion Science Tiger LT handheld detector for Volatile Organic Compounds (VOCs) with PID sensor (0-5000ppm). 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, backlit keypad and data logger. ATEX, IECEx, UL and CSA approvals.

Configure

$2,577.40 
C2-01-061-05/00-000-00/0-0-0-0-0/0-0
(382)

GDS  C2-01-061-05/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local DELRIN sensor head with PID (Photoionization Detector) integrated sensor for VOC with range 0-50 to 0-300 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Configure

$2,850.00 
GMCX-01-61-05/00-00-00/0
(3311)

GDS  GMCX-01-61-05/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,875.00 
059-A110-000
(4131)

RAE  059-A110-000

MiniRAE Lite PGM-7300 Portable Handheld Volatile organic compund (VOC) 10.6 eV 0-5000ppm Detector with photoionization (PID) sensor. Field-interchangeable battery pack. Display and flashlight. Audible and visual alarms. Multi-language support. IP65.

Configure

$2,956.40 
FAXSXBXX-3000D
(5955)

ION SCIENCE  FAXSXBXX-3000D

Ion Science Falco Fixed Detector for Volatile Organic Compounds (VOCs) in condensing atmospheres and extreme weather. PID sensor. Pumped or diffused versions available. Includes Multi-coloured status display and long-life lamp. ATEX, IECEx, UL and CSA approvals.

Configure

$3,018.40 
GMIIx-00-000-00/01-061-05/1-0900
(1856)

GDS  GMIIx-00-000-00/01-061-05/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with a photoionization detector (PID) to detect VOC (Volatile Organic Compounds) with range 0-50/0-300 ppm Isobutylene Equivalent. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$3,084.94 
059-B100-000
(4132)

RAE  059-B100-000

MiniRAE 3000 PGM-7320 Portable Handheld Volatile organic compund (VOC) 10.6/9.8/11.7 eV 0-15000ppm Detector with photoionization (PID) sensor. Big graphic display and Flashlight. Audible and visual alarms. Multi-language support. Optional Rechargeable Li-Ion battery and Wireless versions. IP65/IP67. UL, cUL (Class I Div 1) and ATEX approved.

Configure

$4,274.05 
PTXSLBMP-0005
(5163)

ION SCIENCE  PTXSLBMP-0005

Ion Science Tiger PID (photoionization) hand held detector for Volatile Organic Compounds (VOCs) with dynamic range ppb to 20000ppm and internal gas table with over 480 compounds. 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad backlit and data logger. ATEX, IECEx, UL and CSA approvals.

Configure

$4,370.80 
D03-0009-000
(4307)

HONEYWELL  D03-0009-000

Honeywell RAEGuard 2 PID Photoionization Detector for VOCs (Volatile Organic Compounds). 10 to 28 VDC. 4-20mA three-wire and RS-485 Modbus outputs. Explosion-proof stainless-steel enclosure. Graphic display. LED light status indicator. IP65. UL approved for Class I Div 1. (Zone 1). ATEX and IECEx also available.

Configure

$5,494.23 
059-D100-000
(4133)

RAE  059-D100-000

UltraRAE 3000 PGM-7360 Portable Handheld Compound-Specific Volatile organic compund (VOC) 9.8/10.6/11.7 eV 0-9999ppm Detector with photoionization (PID) sensor. Optional Benzene or Butadiene sensors. Large graphic display. Audible alarm. Multi-language support. Optional Rechargeable Li-Ion battery version. IP65. UL, cUL (Class I Div 1), ATEX, CSA and IECEx approved.

Configure

$5,634.45 
059-C100-000
(4134)

RAE  059-C100-000

ppbRAE 3000 PGM-7340 Portable Handheld Volatile organic compund (VOC) 9.8/10.6 eV 0-9999ppm Detector with photoionization (PID) sensor. Large graphic display. Audible alarm. Optional Rechargeable Li-Ion battery version. IP67. UL, cUL (Class I Div 1), ATEX and IECEx approved.

Configure

$7,135.45