Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

DISPLAY   4-20 mA   RELAYS

961-070026-01PC   
Please Email us your request for quote   

Terminal Material
Approval
Alarm Relay Module

   3 Weeks  ]
9 Variants of base SKU

Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a 3⁄4 inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.

Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

Features
  • XP-intrinsically Safe
  • Class I, Div. 1, Groups B, C & D
  • 2 Wire Loop powered
  • Field Replaceable Electrochemical Sensor
  • Non-intrusive Magnetic Interface
  • Built-in Diagnostics
  • Fully Encapsulated ITM Electronics
  • Electropolished 316SS Construction ITM
  • Quick Thread Release (for sensor replacement)
  • Integral Calibration Port
Applications
  • Oil and Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Waste Water Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type
Span Drift<5% signal loss per year (in first 2 years)
OutputsLinear 4-20 mA DC
Electrical ClassificationExplosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Measurement Range0-100 ppm, Other ranges available
Safety ApprovalsCCSAUS
Sensor Life/WarrantyPlug-in cell - 2 years (2 years expected life) ; Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-4 to 104oF/-40 to 40oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range0% to 99% RH non-condensing (continuous)
0%-100% RH (intermittent)
Operating Pressure RangeAtmospheric ±10%
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5" (140mm) center to center
Weight2 lbs; 0.907 kg (sensor only)
6 lbs; 2.72 kg (w/aluminum j-box)
9 lbs; 4.08 kg (w/stainless steel j-box)
Electrical Specifications
Power Input11 - 30 VDC
Power ConsumptionNormal operation = 30mA @ 24V (<0.75 watt)
Maximum = 50mA @ 24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)< br/> 0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Status IndicatorsOptional 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
943-000000-000
(6566)

DETCON  943-000000-000

Detcon Calibration Sleeve/Wind Guard for use with sensor splash guard for all Detcon sensor heads.



 
> HYDROGEN :    29 Items found.
M001-0019-000
(6329)

MPOWER  M001-0019-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen (H2) 0-1000ppm or 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$299.28 
70-2900-0507-1
(7309)

AIMSAFETY  70-2900-0507-1

AimSafety PM100 Portable Gas Detector (Two Year Disposable) for Hydrogen (H2) 0-1000 ppm. LCD display. Audible, visual and vibrating alarms. IP67. UL & CSA Class I Div 1, Div 2, ATEX, IECEx, INMETRO.



$304.00 
SV-3604
(7375)

PROSENSE  SV-3604

Prosense SafeVader SV-3604 Fixed Gas Detector with Electrochemical sensor for Hydrogen (H2) with range 0-500 ppm to 0-2000 ppm. 4-20 mA Analog, Modbus RS485 RTU and relay outputs (Alarm1, Alarm2, Fault). 12 to 28VDC. ABS Plastic enclosure. IP54.

Configure

$366.92 
P-3634
(6776)

PROSENSE  P-3634

Prosense P-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$564.86 
PXN-3634-1/2
(7324)

PROSENSE  PXN-3634-1/2

Prosense PXN-3635 Gas Detector with Electrochemical sensor for Hydrogen (H2) with range 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$717.29 
BWS1-R-Y
(6387)

BW  BWS1-R-Y

BW Solo Serviceable Single-gas Detector for Hydrogen (H2) 0-1000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PQN-3634-1/2
(6948)

PROSENSE  PQN-3634-1/2

Prosense PQN-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Marine Bureau Veritas Certification (MED), Alarm Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$797.98 
PXD-3634-1/2
(7323)

PROSENSE  PXD-3634-1/2

Prosense PXD-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with range 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. LCD Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$869.71 
PQD-3634-1/2
(6737)

PROSENSE  PQD-3634-1/2

Prosense PQD-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Marine Bureau Veritas Certification (MED), Alarm Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$968.34 
SPSTAXG1
(1487)

HONEYWELL  SPSTAXG1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen (H2) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20 mA loop output. ATEX Approved. (Optional ranges: 0-1000 ppm, 0-10000 ppm)

Configure

$1,116.94 
GG-H2-EC-2000
(2965)

CALIBRATION TECHNOLOGIES  GG-H2-EC-2000

CTI GasGuard H2 Hydrogen Catalytic Bead Sensor 0-1% (10000 ppm or 25%LEL) for gas leak detection in battery charging rooms, steel industry, refineries and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,142.66 
100-0008-00-SS-2-2/100-0015-CAT-H2
(4753)

ESP SAFETY  100-0008-00-SS-2-2/100-0015-CAT-H2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Hydrogen (H2) 0-4% vol or 0-100ppm (Catalytic bead or electrochemical). Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Div 1 certification. Optional 2nd sensor available.

Configure

$1,307.65 
2106B1416
(1462)

HONEYWELL  2106B1416

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen (H2) (0-1000 ppm to 0-10000 ppm) with Surecell Toxic Sensor. 2 wire 4-20 mA loop output. ATEX/IECEx CSA Class I Div 2 Certified.

Configure

$1,352.57 
GG-H2-EC-10000-EXP
(5978)

CALIBRATION TECHNOLOGIES  GG-H2-EC-10000-EXP

CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,408.44 
SPXCDULNG1
(665)

HONEYWELL  SPXCDULNG1

Honeywell XCD Sensepoint Gas Detector, Hydrogen (H2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen (H2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 1,000ppm only. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,883.06 
961-840026-100C
(6363)

DETCON  961-840026-100C

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div 1, Groups A, B, C, & D. Optional Alarm Relays.

2100AL-0-1018/0500P/L0
(120)

RC SYSTEMS  2100AL-0-1018/0500P/L0

RC Systems SenSmart 2100 2 wire 4-20 mA Loop Powered gas detector for Hydrogen (H2) 0-2000 ppm or 0-100% LEL with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class I Div 1 & 2 (Explosion Proof).

Configure

$2,038.96 
41001AL-0-1019/0500P/L0
(7163)

RC SYSTEMS  41001AL-0-1019/0500P/L0

RC Systems SenSmart 4100 2-wire 4-20 mA loop powered gas detector for Hydrogen (H2) 0-2000 ppm or 0-100% LEL with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class I Div 1 & 2 (Explosion Proof).

Configure

$2,074.02 
51001AL-0-1019/0500P/L0
(7126)

RC SYSTEMS  51001AL-0-1019/0500P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen (H2) 0-2000 ppm or 0-100% LEL with GEN2 smart Electrochemical sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$2,129.87 
S3KUL2-XNXXSG1SS
(689)

HONEYWELL  S3KUL2-XNXXSG1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN (H2) with electrochemical sensor, 2-wire 4-20 mA loop, LCD Display. Optional ranges: 0-1,000ppm ,0-10,000ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure