Ion Science Txsxslbmp-0517 | Benzene | Gas Detectors (handheld) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

ION SCIENCE   TXSXSLBMP-0517

ION SCIENCE TXSXSLBMP-0517
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Ion Science Tiger XTS Select handheld detector for Total Aromatic Compounds (TACs) including Benzene, Toluene and Acetone with PID sensor (up to 20000ppm). 10.0 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger Select ***

TXSXSLBMP-0517   
5,899.60

Version

   In Stock  ]
2 Variants of base SKU

Rapidly detects Benzene & Total Aromatic Compounds (TACs) providing the most accurate reliable data available!

Utilizing the high output ION Science 10.0 eV lamp, the Tiger XT Select (XTS) portable benzene gas detector is capable of detecting Total Aromatic Compounds (TACs) including Benzene, Toluene and Acetone. The instrument is supplied with a pack of benzene pre-filter tubes to detect benzene selectively. The tube can be easily attached to ensure rapid detection and selective measurement of benzene. Throughout the measurement process, Tiger XT Select benzene gas detector continuously displays real time data. Tiger XT Select can also provide 15 minute short term exposure limits (STELs) and 8 hour time weighted averages (TWAs) for Total Aromatic Compounds (TACs).

The Tiger XT Select handheld benzene gas detector can be used in standard operational mode without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs).

Key Features
  • Improved Robust Design: The instrument’s rugged body can withstand harsh environments
  • Long Rechargeable Battery Life: When fully charged, the lithium-ion battery can last up the 24 hours
  • IP65 Ingress Protection: Protection against a range of conditions and weather temperatures
  • Fast Response Time & Clear Down: <2 second response time, one of the fastest and most accurate on the market
  • Instantaneous Alarms: Bright visible alarms: RED & AMBER with loud sounder (95 dBA at 300 mm (12”))
  • Humidity Resistant and Anti-Contamination Design: Patented Fence Electrode Technology ensures optimal performance and extends run time
Tiger XT Select Features
  • Benzene pre-filter tube to detect Benzene selectively
  • Low cost consumables including filters
  • An integrated torch designed for dimly lit areas
  • Flashing LEDS (low & high alarms)
  • A large, clear backlit display for easy viewing in any light condition
  • Loud alarms (Sounder 95 dBA at 300 mm)
  • Large clear keypad designed for one handed operation
  • Improved robust design
  • Li-ion battery life typically up to 24 hours (charge time 8 hours)
  • Intrinsically safe and meets ATEX, IECEx, North American and Canadian Standards
Basic & Advanced Modes

For simplicity and ease of use, the Tiger XT Select has been split into two, user-friendly modes: Basic & Advanced. Basic mode is designed to only offer the core functions for the detection of benzene and other TACs. In advanced mode, all operational modes are available including standard running, TAC and Tube mode.

Typical Applications

Typical applications for the Tiger XT Select include: Confined Space Entry, Plant Maintenance, Marine Down-Stream Monitoring, Hazardous Material Response, TAC detection at loading docks and barge operations.

5 Year Extended Warranty

The Tiger XT Select can be registered online which extends warranty to up to 5 years. Register your instrument online within one month of purchase to extend the warranty.

TECHNICAL SPECIFICATION
Minimum sensitivity (PPM model)Standard running mode: 0.1 ppm
TAC mode: 0.01 ppm
Tube mode 0.01 ppm (res. 0.001 ppm)
Minimum sensitivity (PPB model)TAC mode: 0.001 ppm
Tube mode: 0.01 ppm (res. 0.001 ppm)
Maximum readingStandard mode up to 20,000 ppm or 20,000 mg/m 3 *
Tube mode 200 ppm or 639 mg/m 3 benzene
Response time130 seconds at 68°F (variable) Progressive indication of benzene breakthrough is displayed in real time
Accuracy+/- 10% display reading +/- one digit Benzene (tube mode)
Intrinsically safe approvalsEx II 1G Ex ia IIC T4 Ga
Tamb = 5 o F ≤Ta ≤ 113 o F (with lithium ion battery pack)
Tamb = 5 o F ≤Ta ≤ 104 o F (with alkaline battery pack)
ITS-I22ATEX35111X
IECEx ITS 22.0025X
ITS22UKEX0635X
3193491 conforms to UL Std. 913, 61010-1
Certified to CAN/CSA std. C22.2 No. 61010-1
Class 1 Division 1. Approval for Groups A, B, C & D, T4
Battery lifeLi-ion: life up to 24 hours, charge time 8 hours
Alkaline: 3 x AA, typically 8.5 hours life
Lamps10.0 eV Krypton PID lamp
Data logging*120,000 data log points including date and time stamp
CommunicationDirect USB 1.1
Calibration2 and 3 point calibration (via calibration kit accessory)
AlarmFlashing LEDs Amber (low alarm) Red (high alarm)
Sounder 95 dBA at 300 mm (12”)
Vibration on alarm
Pre-programmed TWA and STEL*
Flow rate≥ 220 ml/min (with blocked flow alarm)
TemperatureOperating: -4 to 140 °F
Humidity: 0-99% RH (non condensing)
ProtectionDesigned to IP65
EMC tested to EN61326-1:2013 & EN50270:2015 & CFR 47:2008 Class A
Weight & dimensions370 mm (H) x 91 mm (W) x 60 mm (D)
870g
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)90271000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
ISC-1810-2939-EQUIV
(2581)

PORTAGAS  ISC-1810-2939-EQUIV

Calibration Gas Isobutylene 100ppm Balance Air 100 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID tag)

Configure

$124.51 
CYL-90094898
(1271)

PORTAGAS  CYL-90094898

Calibration Gas Benzene (C6H6) 5 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$236.32 
DFR-90412867
(1665)

PORTAGAS  DFR-90412867

Portagas demand flow regulator, low pressure DFR inlet 0-1000 PSI 5/8-18 UNF C-10 inlet 3/16" hose barb outlet (horizontal), on-demand Flow 0-3 LPM for 58DS, 103DS, 58DAL, 34DAL, 58GAL, 100GAL, 116GAL, DAL and DS (disposable aluminum and steel) cylinders. Aluminum body for non-reactive gases only.

Configure

$252.22 
TXLLSLBMR-0000
(5956)

ION SCIENCE  TXLLSLBMR-0000

Ion Science Tiger XTL handheld detector for Volatile Organic Compounds (VOCs) with PID sensor (0-5000ppm). 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger LT ***

Configure

$3,724.00 
TXXXSLBMP-0005
(5163)

ION SCIENCE  TXXXSLBMP-0005

Ion Science Tiger XT Select PID (photoionization) handheld detector for Volatile Organic Compounds (VOCs) with dynamic range 1ppb to 20000ppm and internal gas table with over 750 compounds. 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, UL and CSA approvals. *** Replaces Tiger ***

Configure

$6,188.70 
> BENZENE :    1 Items found.
967-PM5520-01K
(5823)

DETCON  967-PM5520-01K

Detcon PI-701 Universal Smart Gas Sensor with Photo Ionization Detector (PID) technology for Benzene 0-1000ppm. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Built-in numeric display. Water-Proof, Corrosion-Proof and Vibration-Proof. NEMA4X. IP66. CSA (Class I Div 1) and ATEX Approvals.

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.