Notifier Xp6-c | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   XP6-C

SKU# (5122)
NOTIFIER XP6-C
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.

Please Email us your request for quote   

   4 Weeks  ]

NOTIFIER’s XP6-C six-circuit supervised control module provides intelligent alarm systems with supervised monitoring of wiring to load devices that require an external power supply to operate, such as horns, strobes, or bells. Each module is intended for switching applications involving AC DC or audio, which require wiring supervision. Upon command from the control panel, the XP6-C will disconnect the supervision and connect the external power supply across the load device.

The first module is addressed from 01 to 154 while the remain- ing modules are automatically assigned to the next five higher addresses. Each XP6-C module has terminals for connection to an external supply circuit for powering devices on its notifi- cation appliance circuit (NAC). One or multiple power supplies or amplifiers may be used.

NOTE: Provisions are included for disabling a maximum of three unused addresses.

Each XP6-C module features a short-circuit-protection monitor to protect the external power supply against short-circuit con- ditions on the NAC. When an alarm condition occurs, the relay which connects the external supply to the NAC will not be allowed to close if a short-circuit condition currently exists on the NAC. Additionally, an algorithm is incorporated to find shorts when the module is active. The XP6-C module will close all circuits that are not shorted to find the NAC with the problem.

Each XP6-C module has panel-controlled green LED indica- tors. The panel can cause the LEDs to blink, latch on, or latch off.

The SYNC-1 accessory card provides the XP6-C with additional functionality with compatible System Sensor® SpectrAlert® and SpectrAlert Advance® audio/visual devices.

Features
  • Six addressable Style B (Class B) or three addressable Style D (Class A) outputs that function as notification appli- ance/speaker/telephone circuits.
  • Removable 12 AWG (3.31 mm2) to 18 AWG (0.821 mm2) plug-in terminal blocks.
  • Status indicators for each point.
  • Unused addresses may be disabled (up to 3).
  • Rotary address switches.
  • FlashScan® or CLIP operation.
  • Optional SYNC-1 accessory card for SpectrAlert and SpectrAlert Advance devices.
  • Mount one or two modules in a BB-XP cabinet (optional).
  • Mount up to six modules on a CHS-6 chassis in a CAB-3 Series, CAB-4 Series, EQ Series, or BB-25 cabinet (optional).
  • Mounting hardware included
Agency Listings and Approvals

These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S635 (XP6-C); S3705 (SYNC-1).
  • ULC Listed: S635 (XP6-CA).
  • MEA Listed: 43-02-E / 226-03-E (SYNC-1).
  • FDNY: COA#6121.
  • FM Approved (Local Protective Signaling).
  • CSFM: 7300-0028:0219 (XP6-C). 7300-1653:0160 (SYNC-1).
  • Maryland State Fire Marshal: Permit # 2106 (XP6-C).

Specifications
Standby current2.25 mA (SLC current draw with all addresses used; if some addresses are disabled, the standby current decreases).
Alarm current35 mA (assumes all six NACS have been switched once and all six LEDs solid ON).
Temperature range32°F to 120°F (0°C to 49°C) for UL appli- cations; –10°C to +55°C for EN54 applications.
Humidity10% to 85% noncondensing for UL applications; 10% to 93% noncondensing for EN54 applications.
Dimensions6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x 1.25" (31.75 mm) deep.
Shipping weight1.1 lb. (0.499 kg) including packaging.
Mounting optionsCHS-6 chassis, BB-25 cabinet, BB-XP cabinet, CAB-3/CAB-4 series backboxes and doors, or EQ Series cabinet.
Wire gauge12 AWG (3.31 mm2) to 18 AWG (0.821 mm2), grounded.
XP6-C is shipped in Class B positionremove shunt for Class A operation.
Maximum NAC wiring resistance40 ohms
Power rating per circuitto 50 W @ 70.7 VAC; 50 W @ 25 VAC (UL applications only).
Current ratings3.0 A @ 30 VDC maximum, resistive, non-coded.
2.0 A @ 30 VDC maximum, resistive, coded.
1.0 A @ 30 VDC maximum, inductive (L/R = 2 ms), coded.
0.5 A @ 30 VDC maximum, inductive (L/R = 5 ms), coded.
0.9 A @ 70.7 VAC maximum (UL only), resistive, non- coded.
0.7 A @ 70.7 VAC maximum (UL only), inductive (PF = 0.35), non-coded.
Compatible devicesSee the documentation for your panel, and the NOTIFER Device Compatibility document. Contact NOTIFER. See also list of devices compatible with SYNC-1 below.

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    42 Items found.
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | 3 | All