Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (4753)

ESP SAFETY  100-0008-A1/100-0015-H2

$1,440.00     Availability: 3 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



ESP SAFETY 100-0008-A1/100-0015-H2 (1)
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE

ESP Safety Vector 2-channel gas detector controller with smart Plug-In Sensor to Detect Hydrogen (H2) 0-4% vol or 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification.

Part# with Options:        100-0008-A1/100-0015-H2
Price with Options:        1,440.00

Options:    

Gas Range
(1) Gas Range for ESP Safety PGU H2
Optional Sensor
(2) Sensor for ESP Safety Vector

  Availability 3 Weeks  ]


ESP Safety’s Vector is a state-of the-art field control unit that performs as an integrated control terminal and display for ESP Safety’s gas detector product line.

The Vector can operate as a stand-alone display for a variety of ESP Safety’s detectors which can be remotely located up to 500 feet away. A sensor head can also be attached directly to the display housing to produce a unified detector/display unit.

Key Features
  • A vivid, 2.7” (diagonal) 128x64 pixel resolution, OLED screen simultaneously displays a wide range of data including gas concentrations, alarm levels, faults and operational modes.
  • Analog 4-20 current loop w/ HART , Digital RS-485 Modbus RTU and 4 relays are standard data communication channels of the VECTOR FCU
  • Event log is stored in on-board memory and is accessible via RS-485 Modbus RTU
  • Operating Temp Range of -58°F to +167°F (-50°C to +75°C)
  • Configurable to control & monitor up to 2 detectors
  • SIL certification by independent 3rd party agency
  • 316 Stainless Steel construction, explosion-proof housing, Class 1, Division 1
  • Non-Instrusive, on-site detector calibration via a HART Field Communicator or Magnectic Wand
Applications
  • Offshore platforms
  • Land rigs
  • Shipping tankers, freighters, and other vessels
  • LNG/LPG processing & storage facilities
  • Oil & gas refineries
  • Petrochemical plants
  • Gas & electric utilities
Additional Features
  • Non-intrusive operator interface is easily achieved by contacting a magnetic wand with the glass housing cover and accessing the intuitive, menu-driven programming screen
  • Tri-color status LED indicates operational mode, fault & gas presence
  • Two - Analog 4-20mA Relay Outputs
  • Four - Direct Relay Outputs are standard

Specifications
Electrical Characteristics
Voltage+24VDC Nominal (+18 to 32VDC)
Power4.3 W, standby 5.3 W, during alarm
12.0 W with heater on (temp ≤ 30°C)
OutputsAnalog signal: 2x +4-20mA
Digital RS-485 Modbus RTU
HART communication port
Three User Programmed Alarm Relays
One Fault Condition Programmed Relay
Technical Specifications
Humidity0 to 100% relative humidity, non condensing
Operating Temperature-58°F to +167°F (-50°C to +75°C)
-76°F to +167°F (-50°C to +75°C), with heater enabled
Storage temperature-76°F to +185°F (-60°C to +85°C)
Ingress ProtectionIP67
SIL RatingSIL 2, FM/CSA Class I Division 1 certification
Mechanical Characteristics
Material316 Stainless Steel
Conduit Connection5 Conduit Entrances , 3/4” NPT
Dimensions7.50” x 5.60” x 4.28”
Weight12.8 lbs (5.8 kg)
Warranty5 years
 


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
100-0015-H2
(4743)

ESP SAFETY  100-0015-H2

ESP Safety Sensor Assy, PGU-Hydrogen (H2); Plug-in sensor & stainless steel housing. Includes weather protective dust cap.



$690.00 
> HYDROGEN :    22 Items found.
M001-0018-000
(6329)

MPOWER  M001-0018-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen (H2) 0-1000ppm or 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$268.20 
P-3634
(6776)

PROSENSE  P-3634

Prosense P-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$459.00 
G02-BM10-100
(3028)

RAE  G02-BM10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen (H2) 0-1000 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

BWS_-R-Y
(6387)

BW  BWS-R-Y

BW Solo Serviceable Single-gas Detector for Hydrogen (H2) 0-1000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PQN-3634-1/2
(6948)

PROSENSE  PQN-3634-1/2

Prosense PQN-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$630.00 
SPSTAXG1
(1487)

HONEYWELL  SPSTAXG1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen (H2) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-1000 ppm, 0-10000 ppm)

Configure

$752.30 
PQD-3634-1/2
(6737)

PROSENSE  PQD-3634-1/2

Prosense PQD-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$756.00 
GG-H2-EC-2000
(2965)

CALIBRATION TECHNOLOGIES  GG-H2-EC-2000

CTI GasGuard H2 Hydrogen Catalytic Bead Sensor 0-1% (10000 ppm or 25%LEL) for gas leak detection in battery charging rooms, steel industry, refineries and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$900.90 
2106B1416
(1462)

HONEYWELL  2106B1416

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen (H2) (0-1000 ppm to 0-10000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$921.03 
GG-H2-EC-10000-EXP
(5978)

CALIBRATION TECHNOLOGIES  GG-H2-EC-10000-EXP

CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,110.20 
SPXCDULNG1
(665)

HONEYWELL  SPXCDULNG1

Honeywell XCD Sensepoint Gas Detector, Hydrogen (H2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen (H2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 1,000ppm only. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,381.05 
961-070026-01PG
(6053)

DETCON  961-070026-01PG

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

Configure

$1,479.21 
961-840026-100G
(6363)

DETCON  961-840026-100G

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-100ppm Sensor Assembly with loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

Configure

$1,479.21 
EX-H2-100L-O
(6023)

MACURCO  EX-H2-100L-O

Macurco Ex Series Explosion Proof Catalytic Bead Gas Detector for detection of Hydrogen (H2) 0-100%LEL. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. CSA approvals for Class I Division 2.

Configure

$1,481.25 
S3KUL2-XNXXSG1SS
(689)

HONEYWELL  S3KUL2-XNXXSG1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN (H2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-1,000ppm ,0-10,000ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,558.83 
SPXCDULNG2
(5102)

HONEYWELL  SPXCDULNG2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen (H2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 1000 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,572.89 
31001AL___-0-9018/2000P/L0
(5782)

RC SYSTEMS  31001AL-0-9018/2000P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen (H2) 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 1 (Explosion Proof).

Configure

$1,908.53 
967-070790-01P
(6088)

DETCON  967-070790-01P

Detcon DM-702-H2 Electrochemical "Smart" Hydrogen (H2) 0-1% vol. Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Configure

$1,948.46 
XNXUTAENNNNN-XNXXSG1SS
(839)

HONEYWELL  XNXUTAENNNNN-XNXXSG1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen (H2) compatible with all Honeywell gas sensing technologieswith aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-1000ppm, 0-10000ppm

Configure

$1,957.58 
967-848490-100
(6087)

DETCON  967-848490-100

Detcon DM-700-H2 Electrochemical "Smart" Hydrogen (H2) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Configure

$2,055.61 
Page: 1 | 2 | All