Esp Safety 100-0008-a1/100-0015-co2 | Carbon Dioxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

ESP SAFETY   100-0008-A1/100-0015-CO2

ESP SAFETY 100-0008-A1/100-0015-CO2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Carbon Dioxide (CO2) 0-2% vol, 0-5% vol or 0-3000ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

100-0008-A1/100-0015-CO2
1,440.00

Gas Range
Optional Sensor

 3 Weeks  ]



ESP Safety’s Vector is a state-of the-art field control unit that performs as an integrated control terminal and display for ESP Safety’s gas detector product line.

The Vector can operate as a stand-alone display for a variety of ESP Safety’s detectors which can be remotely located up to 500 feet away. A sensor head can also be attached directly to the display housing to produce a unified detector/display unit.

Key Features
  • A vivid, 2.7” (diagonal) 128x64 pixel resolution, OLED screen simultaneously displays a wide range of data including gas concentrations, alarm levels, faults and operational modes.
  • Analog 4-20 current loop w/ HART , Digital RS-485 Modbus RTU and 4 relays are standard data communication channels of the VECTOR FCU
  • Event log is stored in on-board memory and is accessible via RS-485 Modbus RTU
  • Operating Temp Range of -58°F to +167°F (-50°C to +75°C)
  • Configurable to control & monitor up to 2 detectors
  • SIL certification by independent 3rd party agency
  • 316 Stainless Steel construction, explosion-proof housing, Class 1, Division 1
  • Non-Instrusive, on-site detector calibration via a HART Field Communicator or Magnectic Wand
Applications
  • Offshore platforms
  • Land rigs
  • Shipping tankers, freighters, and other vessels
  • LNG/LPG processing & storage facilities
  • Oil & gas refineries
  • Petrochemical plants
  • Gas & electric utilities
Additional Features
  • Non-intrusive operator interface is easily achieved by contacting a magnetic wand with the glass housing cover and accessing the intuitive, menu-driven programming screen
  • Tri-color status LED indicates operational mode, fault & gas presence
  • Two - Analog 4-20mA Relay Outputs
  • Four - Direct Relay Outputs are standard

Specifications
Electrical Characteristics
Voltage+24VDC Nominal (+18 to 32VDC)
Power4.3 W, standby 5.3 W, during alarm
12.0 W with heater on (temp ≤ 30°C)
OutputsAnalog signal: 2x +4-20mA
Digital RS-485 Modbus RTU
HART communication port
Three User Programmed Alarm Relays
One Fault Condition Programmed Relay
Technical Specifications
Humidity0 to 100% relative humidity, non condensing
Operating Temperature-58°F to +167°F (-50°C to +75°C)
-76°F to +167°F (-50°C to +75°C), with heater enabled
Storage temperature-76°F to +185°F (-60°C to +85°C)
Ingress ProtectionIP67
SIL RatingSIL 2, FM/CSA Class I Division 1 certification
Mechanical Characteristics
Material316 Stainless Steel
Conduit Connection5 Conduit Entrances , 3/4” NPT
Dimensions7.50” x 5.60” x 4.28”
Weight12.8 lbs (5.8 kg)
Warranty5 years
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    2 Items found.
100-0015-CO2
(4741)

ESP SAFETY  100-0015-CO2

ESP Safety Sensor Assembly, PGU-Carbon Dioxide (CO2) Plug-in sensor & stainless steel housing; Includes weather protective dust cap.

Configure

$690.00 
100-0009-01-A
(4724)

ESP SAFETY  100-0009-01-A

ESP Safety UPES 16-channel (4-20mA) gas and flame detector controller, or 128 Modbus digital RS-485 channels (16 ports 8 channels each) for ESP Devices. Includes Modbus RS-485 output port (both analog and digital versions), power supply and 3 alarm relays and audible alert. 3Ux19" modular size, FM & ABS Class I Division 1, Ex CE and IECEx Approved.

Configure

$1,732.50 
> CARBON DIOXIDE :    35 Items found.
I-M308WV
(2955)

INTEC  I-M308WV

Intec Controls I-M308 Infrared (NDIR) Gas Transmitter for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-(5)10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm) and 24 VAC/VDC powered.

Configure

$149.88 
I-M350WV-R000
(2956)

INTEC  I-M350WV-R000

Intec Controls I-M350 Infrared (NDIR) Gas Transmitter and Control System for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm). Optional relay/ouput control, audible alarm, LCD Display and relative humidity measurement.

Configure

$168.72 
SAN-10
(7050)

CO2METER  SAN-10

CO2Meter SAN-10 Personal Safety Monitor for Carbon Dioxide (CO2) 0-5% with NDIR sensor. Visual strobe light, audible and vibrating alarmas. Includes rechargeable Li-Ion battery, 110/240 VAC USB Wall Adapter and LCD Display. IP54 rubber enclosure.



$383.04 
CD-6MC
(4482)

MACURCO  CD-6MC

MACURCO CD-6 low voltage Carbon Dioxide (CO2) 0-5000ppm Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$470.15 
CD-6G
(6828)

MACURCO  CD-6G

MACURCO CD-6G / CD-6B Greenhouse Carbon Dioxide (CO2) 0-5% vol Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. Auto or Manual Calibration (Relays, 4-20mA output). ETL Listed to UL 61010-1.

Configure

$470.15 
CD-12MC
(4494)

MACURCO  CD-12MC

MACURCO CD-12 line voltage Gas Detector, controller and transducer for Carbon Dioxide (CO2) 0-5000ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$481.95 
6302-0090
(6239)

BACHARACH  6302-0090

Bacharach MGS-410 Gas Detector Transmitter with infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

6302-1090
(6249)

BACHARACH  6302-1090

Bacharach MGS-450 Gas Detector Transmitter with infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Factory configured for either R600 or R290. Mobile App Bluetooth Interface.

SAN-13
(7051)

CO2METER  SAN-13

CO2Meter SAN-13 Personal Leak Detector for Carbon Dioxide (CO2) 0-20% with NDIR sensor. Audible and visual indicator. Includes rechargeable Li-Ion battery, 110/240 VAC USB Wall Adapter and OLED Display. IP54 rubber enclosure.



$623.04 
RAD-0102-6
(7048)

CO2METER  RAD-0102-6

CO2Meter RAD-0102-6 Remote "CO2 Storage Safety 3" gas leak detector with local and remote displays for Carbon Dioxide (CO2) 0-5% (0-50,000 ppm) with NDIR sensor. Includes audible and visual alarms, 3 alarm relays, 4-20 mA output and LCD display. IP54 Enclosure. UL Listed, meets NFPA, IFC, and NBIC requirements, OSHA and NIOSH TWA standards. Alarms 5,000 TWA, 1.5% (user configurable), 3% (user configurable), sensor life > 15 years, 12-24VDC power, includes 110-220VAC multi-region power adapter.

Configure

$672.00 
6302-4090
(6259)

BACHARACH  6302-4090

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

364-510-01
(6148)

DELPHIAN  364-510-01

Delphian GazTell Fixed Point Infrared Gas Detector for Carbon Dioxide (CO2) 0.02% to 4.5% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

P-7133
(6786)

PROSENSE  P-7133

Prosense P-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with range 0-5000ppm or 0-5% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$772.20 
PQN-7133-1/2
(6959)

PROSENSE  PQN-7133-1/2

Prosense PQN-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with ranges 0-5000ppm or 0-5%vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$943.80 
PQD-7133-1/2
(6747)

PROSENSE  PQD-7133-1/2

Prosense PQD-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with ranges 0-5000ppm or 0-5%vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,115.40 
6600-8010
(6267)

BACHARACH  6600-8010

Bacharach MGS-550 Industrial Refrigerant Gas Detector with infrared sensor for Carbon Dioxide (CO2) 0-5000ppm to 0-50000ppm. 3 x relays, analog output, RS485 MODBUS output and 5-digit display. Remote sensor capabilities. IP66 Housing. CE, UL and CSA Approvals.

1400ALD-101032/015P-L0
(6906)

RC SYSTEMS  1400ALD-101032/015P-L0

RC Systems SenSmart 1400 gas detector for Carbon Dioxide (C02) 0-1.5% or 0-5% with 'ST-48' smart transmitter. IR sensor. 3-Wire bridge. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,446.75 
GG-CO2-1
(2964)

CALIBRATION TECHNOLOGIES  GG-CO2-1

CTI GasGuard CO2 Carbon Dioxide Infrared Sensor (0-1%, 0-3% and 0-5%) for gas leak detection in wineries, food processing areas, bottling plants and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,474.00 
IR-F9-CO2-1-N1
(1547)

HONEYWELL  IR-F9-CO2-1-N1

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Carbon Dioxide (CO2) with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

Configure

$1,673.41 
SPXCDULNB1
(661)

HONEYWELL  SPXCDULNB1

Honeywell XCD Sensepoint Gas Detector, Carbon Dioxide (CO2) Infrared Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for carbon dioxide (CO2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 2%Vol. only UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,681.17 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.