Gas Leak Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (4722)

ESP SAFETY  100-0001-M11-SS

$1,440.00     Availability: 7 Days
 Info/Quote Request
 Shipping Rates
 Volume discount



ESP SAFETY 100-0001-M11-SS
  • Overview
  • Features
  • Specs
  • Related
  • Literature

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases (Methane, Propane, Butane, Pentane, Hexane, Cyclopentane or Ethanol). Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Division 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Part# with Options:        100-0001-M11-SS
Price with Options:        1,440.00

Options:    

Gases
(1) Gases for ESP Safety SGOES

  Availability 7 Days  ]

ESP Safety’s Model SGOES Gas Detector measures the concentration of hydrocarbon gases present in the monitored environment. The SGOES is configured to report alarms when the gas concentrations in the environment reach the two independently programmable levels, expressed as a percentage of the lower explosive limit (LEL) in air. As determined by application requirements, the SGOES is factory calibrated with one of eight hydrocarbon-based gases (typically methane or propane). Conversion factors are used to correct for gases other than the factory calibration gas.

The SGOES sensor detects and quantifies the presence of hydrocarbons by measuring their absorption of infrared light (IR). Because the device does not depend on the presence of oxygen in a mixture of gases, it can function effectively in environments where other sensor technologies cannot. Moreover, it is not sensitive to gases such as nitrogen, oxygen, carbonic acid, ammonia, and hydrogen sulfide, that may adversely affect other types of sensors. This makes the SGOES an excellent choice for environments where non-hydrocarbon gases are present and where monitoring of hydrocarbons like methane and propane is required.

The explosion-proof design of SGOES makes it ideal for use in hazardous environments such as:

  • Oil and gas facilities
  • Pumping stations
  • Refineries
  • Tank farms
  • Pipelines
  • Loading racks.

SGOES is FM-certified for use in potentially explosive gas/vapor environments in compliance with FM3615 and CSA-C22.2 No 30 standards for explosion proof protection. In addition, it meets CSA standard E60079-1 for flameproof protection, and ANSI/ISA standard 12.13.01-2000 for performance of combustible gas detectors.

The SGOES gas detector is typically used as an indicating device in fire and gas (F&G) detection and suppression systems as well as emergency shutdown (ESD) systems.

The rugged SGOES design allows it to be used in harsh environments. It will operate from -76°F to +185°F (-60°C to +85°C) at relative humidity up to 95%

Applications
  • Drilling and production platforms
  • Shipping tankers, freighters, and other vessels
  • Fuel loading facilities
  • Refineries, bulk terminals, and tank farms
  • LNG/LPG processing and storage facilities
  • Compressor stations and pipeline facilities
  • Petrochemical, paint, and fertilizer plants
  • Power plants and gas turbine facilities
  • Transportation facilities (airports and subways)
  • Oil and gas fired boilers / furnaces
  • Environmental regulation monitoring
Features and benefits
  • High sensitivity to all hydrocarbon gases/vapors for maximum property protection and personal safety
  • Open path optical sensor - no physical contact between sensor and environment
  • IR optical path obstruction monitoring (dust, paint, etc.) provides maintenance alerts
  • Heated optics, secondary heater function helps to prevent condensation problems
  • Low power (<4.5W) operation for cost savings
  • Versatile indoor/outdoor installation
  • Industry standard analog, digital, and relay outputs are used for remote alarm and fault indications
  • Resistance to vibration ensures reliability and durability
  • Operates effectively in fog and high humidity
  • Wide operating temperature range provides flexibility and reliability
  • Tri-color status LED on the device is easily viewable for a visual report of the device’s operating status
Calibration

Factory calibrated at 0%, 20%, 50%, and 95% LEL with methane or propane.

Calibration with NIST traceable calibration gas is optional.

Configuration Options

Standard Gas options:

  • Methane
  • Propane
  • Butane
  • Pentane
  • Hexane
  • Isobutane
  • Cyclopentane
  • Ethanol

Custom Gas configuration options:

  • Volatile Organic Compounds (VOC)
  • Optional calibration with gas mixtures directly traceable to NIST standard reference materials.

Specifications
Electrical Characteristics
Voltage18 to 32 VDC
Power2 W, standby
4.5 W, during alarm
7.9 W, heater on maximum
Outputs4-20mA, analog (0 to 100% LEL) two alarm relays (isolated, dry contact type) with programmable thresholds fault relay indicating optical path obstruction
RS-485 Modbus RTU, HART, Ethernet
Recommended Wiring16 AWG (1.5mm) for 4000ft (1200m) max
Performance
GasesMethane, propane, butane, pentane, hexane, isobutane, cyclopentane, ethanol (The target gas is factory configurable according to customer request.)
Range0 to 100% LEL (lower explosive level – in air)
Accuracy±2% LEL, for 0 to 100% LEL
HumidityUp to 95%, non-condensing (withstands up to 100% RH for short periods)
Response Time (for 100% LEL Methane)50% full scale < 1.9 seconds
90% full scale < 5.0 seconds
Operating Temperature-76°F to +185°F (-60°C to +85°C)
Extended Operating Temperature (By Request)-76°F to +194°F (-60°C to +90°C)
Storage temperature-58°F to +125°F (-50°C to +50°C)
Ingress ProtectionIP66
Wiring14 AWG (2.08 mm) or 16 AWG (1.31 mm)
Shielded cable is recommended
SIL RatingSIL 3
Ingress ProtectionIP66
SIL RatingSIL 2, FM/CSA Class I Division 1 certification
Warranty5 years
Mechanical Characteristics
Material316 Stainless Steel
Diameter5.5” (14 cm)
Length11.5” (29 cm)
Weight14.3lbs (6.5 kg)
Conduit Entry3/4” NPT

  • GAS DETECTORS > 2-CHANNEL
    100-0008-A1 ESP Safety Vector 2-channel gas detector controller . Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal

> LEL INFRARED :    23 Items found.
GDS-50-1-50-06
(1643)

GDS  GDS-50-1-50-06

GDS GDS-50 Remote Infrared IR Sensor Transmiter for Combustible (LEL) 0-100% Vol with replaceable sensor and 4-20 mA Output. Designed for Class 1 Division 1. -20°C to +50°C. Available gases: Methane (CH4), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Ethylene Oxide (ETO), Ethane (C2H6), Hexane (C6H14), Propene (C3H6), Ethylene (C2H4), Acetone (C3H6O) and Ethanol (C2H6O)

Configure

$1,090.00 
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,137.99 
GDS-48-1-50-06
(344)

GDS  GDS-48-1-50-06

GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with SmartIR sensor for combustibles and Methane (CH4) 0-100% LEL (Lower Explosive Limit). 3-Wire Bridge Output. CSA Certified for Div. 1 Explosion Proof.

Configure

$1,145.00 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,225.37 
XNXUTAVNNIV1
(2141)

HONEYWELL  XNXUTAVNNIV1

Honeywell XNX Universal Gas Detector Transmitter including MPD-AM1V1 IR Infrared sensor combustible 0-5% Vol 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,625.12 
XNXUTAVNNIF1
(1225)

HONEYWELL  XNXUTAVNNIF1

Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,625.12 
967-215520-100
(2133)

DETCON  967-215520-100

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor

2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$1,728.57 
2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$1,728.57 
GMII-00-000-00/01-050-06/0-0
(185)

GDS  GMII-00-000-00/01-050-06/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit), 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Ethanol, Toluene, Acetone, MEK and Xylene. CSA Certified for Class I, Div 1.

Configure

$1,970.00 
2108N5100N
(1965)

HONEYWELL  2108N5100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Hydrocarbon calibration (Methane (Natural Gas), Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit), for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output.

Configure

$2,019.85 
GDS-IR-1-110-1
(436)

GDS  GDS-IR-1-110-1

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Combustibles LEL (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Methane (CH4), Propane (C3H8), Isobutane (C4H10), Pentane (C5H12), Cyclopentane (C5H10), n-Butane (C4H10), Ethanol (C2H6O), Methanol (CH4O), Hexane (C6H14), Jet-A, Diesel and Gasoline.

Configure

$2,020.00 
5100-28-IT-A1-01-01-0-0-F
(3081)

SIERRA MONITOR  5100-28-IT-A1-01-01-0-0-F

Sierra Monitor 5200-28-IT Infrared Gas Leak Detector for Combustibles 0-100% LEL (methane and others). ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups C, D.

GD10-P00-17DG-0BH
(1868)

SIMTRONICS  GD10-P00-17DG-0BH

Simrad GD10P IR Point Gas Detector for combustible gases: Methane (CH4) , Ethylene (C2H4), Propane (C3H8), Acetylene, Butane and others on offshore installations. 4-20 mA output with HART. 24 VDC. Available Approvals: ATEX, CSA/US, IECEx, INMETRO, ABS, SIL and MED.

C2-48-050-06/00-000-00/0-0-0-0-0/0-0
(379)

GDS  C2-48-050-06/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local DELRIN sensor head with SmartIR Methane (Natural Gas) integrated sensor with range combustible 0-100% LEL (Lower Explosive Limit) with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Ethanol, Toluene, Acetone, MEK and Xylene.

Configure

$2,245.00 
2108N5110N
(1966)

HONEYWELL  2108N5110N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for gas ranges 0–100 %v/v Methane (CH4), 0–600,000 ppm Propane (C3H8) and 0–400,000 ppm Propane (C3H8). 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional Multidrop Modbus RS485 and HART. Hydrocarbon calibration fitted with remote gassing cell and flow housing.

Configure

$2,310.12 
RMII-00-00-00/02-50-06/1-0-1-0
(5162)

GDS  RMII-00-00-00/02-50-06/1-0-1-0

GDS RigMAX Single Channel Gas Monitor with Integrated strobe and 99dB horn with Infrared sensor for Methane with range 0-100% LEL (Lower Explosive Limit). Includes backlit display and 100 ft #18GA neoprene power cable. 24 VDC. Aluminium Housing and 4 point magnetic mount. CSA Certified for Class 1, Div 1, Groups B, C & D. Available calibrated to Methane (Natural Gas), Propane (LP) and other hydrocarbons.

Configure

$2,430.00 
GMIIx-00-000-00/01-050-06/1-0900
(1854)

GDS  GMIIx-00-000-00/01-050-06/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit). A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Toluene, Acetone, MEK and Xylene.

Configure

$2,436.89 
GMCX-01-50-06/00-00-00/0
(3309)

GDS  GMCX-01-50-06/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit), QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Toluene, Acetone, MEK and Xylene.

Configure

$2,445.00 
XNXUTAINNNNN-2108N4110
(851)

HONEYWELL  XNXUTAINNNNN-2108N4110

Honeywell XNX Universal Gas Detector Transmitter with Optima Plus Infrared Hydrocarbon Gas Detector combustible 0-100% LEL (Lower Explosive Limit) and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1 . Available for over 100 gas and vapour calibrations.

Configure

$2,543.14 