ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases, Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Div 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

RELAYS   FM   IECEX   CSA   UL   DIV 1   SIL2   HART   MODBUS

100-0001-M11-SS-1-2-CH4   
1,490.40

Cable entry 1
Cable entry 2
Gases

   5 Weeks  ]
54 Variants of base SKU / 30 Shown below

ESP Safety’s Model SGOES Gas Detector measures the concentration of hydrocarbon gases present in the monitored environment. The SGOES is configured to report alarms when the gas concentrations in the environment reach the two independently programmable levels, expressed as a percentage of the lower explosive limit (LEL) in air. As determined by application requirements, the SGOES is factory calibrated with one of eight hydrocarbon-based gases (typically methane or propane). Conversion factors are used to correct for gases other than the factory calibration gas.

The SGOES sensor detects and quantifies the presence of hydrocarbons by measuring their absorption of infrared light (IR). Because the device does not depend on the presence of oxygen in a mixture of gases, it can function effectively in environments where other sensor technologies cannot. Moreover, it is not sensitive to gases such as nitrogen, oxygen, carbonic acid, ammonia, and hydrogen sulfide, that may adversely affect other types of sensors. This makes the SGOES an excellent choice for environments where non-hydrocarbon gases are present and where monitoring of hydrocarbons like methane and propane is required.

The explosion-proof design of SGOES makes it ideal for use in hazardous environments such as:

  • Oil and gas facilities
  • Pumping stations
  • Refineries
  • Tank farms
  • Pipelines
  • Loading racks.

SGOES is FM-certified for use in potentially explosive gas/vapor environments in compliance with FM3615 and CSA-C22.2 No 30 standards for explosion proof protection. In addition, it meets CSA standard E60079-1 for flameproof protection, and ANSI/ISA standard 12.13.01-2000 for performance of combustible gas detectors.

The SGOES gas detector is typically used as an indicating device in fire and gas (F&G) detection and suppression systems as well as emergency shutdown (ESD) systems.

The rugged SGOES design allows it to be used in harsh environments. It will operate from -76°F to +185°F (-60°C to +85°C) at relative humidity up to 95%

Applications
  • Drilling and production platforms
  • Shipping tankers, freighters, and other vessels
  • Fuel loading facilities
  • Refineries, bulk terminals, and tank farms
  • LNG/LPG processing and storage facilities
  • Compressor stations and pipeline facilities
  • Petrochemical, paint, and fertilizer plants
  • Power plants and gas turbine facilities
  • Transportation facilities (airports and subways)
  • Oil and gas fired boilers / furnaces
  • Environmental regulation monitoring
Features and benefits
  • High sensitivity to all hydrocarbon gases/vapors for maximum property protection and personal safety
  • Open path optical sensor - no physical contact between sensor and environment
  • IR optical path obstruction monitoring (dust, paint, etc.) provides maintenance alerts
  • Heated optics, secondary heater function helps to prevent condensation problems
  • Low power (<4.5W) operation for cost savings
  • Versatile indoor/outdoor installation
  • Industry standard analog, digital, and relay outputs are used for remote alarm and fault indications
  • Resistance to vibration ensures reliability and durability
  • Operates effectively in fog and high humidity
  • Wide operating temperature range provides flexibility and reliability
  • Tri-color status LED on the device is easily viewable for a visual report of the device’s operating status
Calibration

Factory calibrated at 0%, 20%, 50%, and 95% LEL with methane or propane.

Calibration with NIST traceable calibration gas is optional.

Configuration Options

Standard Gas options:

  • Methane
  • Propane
  • Butane
  • Pentane
  • Hexane
  • Isobutane
  • Cyclopentane
  • Ethanol

Custom Gas configuration options:

  • Volatile Organic Compounds (VOC)
  • Optional calibration with gas mixtures directly traceable to NIST standard reference materials.

Specifications
Electrical Characteristics
Voltage18 to 32 VDC
Power2 W, standby
4.5 W, during alarm
7.9 W, heater on maximum
Outputs4-20mA, analog (0 to 100% LEL) two alarm relays (isolated, dry contact type) with programmable thresholds fault relay indicating optical path obstruction
RS-485 Modbus RTU, HART, Ethernet
Recommended Wiring16 AWG (1.5mm) for 4000ft (1200m) max
Performance
GasesMethane, propane, butane, pentane, hexane, isobutane, cyclopentane, ethanol (The target gas is factory configurable according to customer request.)
Range0 to 100% LEL (lower explosive level – in air)
Accuracy±2% LEL, for 0 to 100% LEL
HumidityUp to 95%, non-condensing (withstands up to 100% RH for short periods)
Response Time (for 100% LEL Methane)50% full scale < 1.9 seconds
90% full scale < 5.0 seconds
Operating Temperature-76°F to +185°F (-60°C to +85°C)
Extended Operating Temperature (By Request)-76°F to +194°F (-60°C to +90°C)
Storage temperature-58°F to +125°F (-50°C to +50°C)
Ingress ProtectionIP66
Wiring14 AWG (2.08 mm) or 16 AWG (1.31 mm)
Shielded cable is recommended
SIL RatingSIL 3
Ingress ProtectionIP66
SIL RatingSIL 2, FM/CSA Class I Division 1 certification
Warranty5 years
Mechanical Characteristics
Material316 Stainless Steel
Diameter5.5” (14 cm)
Length11.5” (29 cm)
Weight14.3lbs (6.5 kg)
Conduit Entry3/4” NPT
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
90095187
(6713)

PORTAGAS  90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
90090227
(1313)

PORTAGAS  90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
90302139
(1259)

PORTAGAS  90302139

Calibration Gas Butane (C4H10) 50% LEL (0.9%) Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
100-0008-00-SS-2-2
(4725)

ESP SAFETY  100-0008-00-SS-2-2

ESP Safety Vector 2-channel gas detector controller . Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Div 1 certification. It can be configured with one or two optional sensors, including: Chlorine (Cl2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Hydrogen (H2), Hydrogen Sulfide (H2S), Methane (CH4), Ammonia (NH3), Oxygen (O2), Propane (C3H8) and Sulfur Dioxide (SO2).

Configure

$1,050.30 
> LEL INFRARED :    30 Items found.
012731-504
(7260)

DET-TRONICS  012731-504

Det-tronics FlexSight LS2000 Infrared gas detection system for combustible hydrocarbon gases 0-5% LEL. 4-20 mA output, HART and RS-485 Modbus communication. 24 VDC. Stainless steel transmitter and receiver. IP66/IP67. NEMA Type 4X. Suitable for Class I, Div 1 and Div 2; Class II, Div 1; Class I, Zone 1; and Zone 1, Zone 2. FM, IEC and SIL 2 Approvals.



 
006300-012
(7250)

DET-TRONICS  006300-012

Det-tronics PIR9400 PointWatch Infrared Hydrocarbon Gas Detector for Methane 0-100% LEL. Diffusion based. 18-30 VDC. 4-20 mA output signal. Explosion proof. IP66. Suitable for Class I Div 1, Div 2, Zone 1 and Zone 2 hazardous areas.



 
116-014048-232
(7230)

AUTRONICA  116-014048-232

Autronica AutroPoint HC200 Infrared IR Hydrocarbon Gas Detector calibrated to methane, propane, ethylene, or butane 0 to 100% LEL. Explosion-proof stainless steel housing. 4-20 mA signal with HART communication. MODBUS and ASCII supported. SIL2, FM/CSA, DEMKO, IECEx and ATEX certified for use in Class I, Div 1 and Div 2, and Zone 1 and Zone 2.



 
P-3033
(6722)

PROSENSE  P-3033

Prosense P-XY35 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$797.94 
PQN-3033-1/2
(6946)

PROSENSE  PQN-3033-1/2

Prosense PQN-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$978.12 
PQD-3033-1/2
(6719)

PROSENSE  PQD-3033-1/2

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,413.89 
1300ALD-109050/100P-L0
(6904)

RC SYSTEMS  1300ALD-109050/100P-L0

RC Systems SenSmart 1300 Infrared (IR) Gas Detector for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide 0-100% LEL or %Vol with 'ST-48' smart transmitter. Infrared (IR) sensor. 3-Wire bridge. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,432.47 
100-0008-00-SS-2-2/100-0015-IR-CH4
(4756)

ESP SAFETY  100-0008-00-SS-2-2/100-0015-IR-CH4

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Div 1 certification. Optional 2nd sensor available.

Configure

$1,593.90 
53001AL-0-9050/100P/L0
(7136)

RC SYSTEMS  53001AL-0-9050/100P/L0

RC Systems SenSmart 5300 3-wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with GEN2 smart sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$1,809.09 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,813.32 
967-215520-100
(2133)

DETCON  967-215520-100

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor Optional Alarm Relays, HART.

2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$2,123.32 
2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$2,123.32 
33001AL-0-9050/100P/L0
(6898)

RC SYSTEMS  33001AL-0-9050/100P/L0

RC Systems SenSmart 3300 3 wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20 mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
PIRECLA11A1BT2
(7027)

DET-TRONICS  PIRECLA11A1BT2

Det-tronics PointWatch Eclipse PIRECL Infrared Gas Detector for detection of Hydrocarbons (methane, propane, ethylene, butane) 0 to 100% LFL. Diffusion based. 4-20 mA signal with HART and RS-485 serial communication. Optional relay output. Explosion-proof and stainless steel housing. 24 Vdc. Certified for use in Class I, Div 1 and Div 2. FM, CSA, ATEX, IECEx, DNV/MED, and INMETRO certifications.

GDS-IR-1-118-0
(1742)

GDS  GDS-IR-1-118-0

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Industrial Process Hydrocarbons (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Propylene (C3H6), Acetylene (C2H2), Methane (CH4), Ethylene (C2H4), Isopropyl Alcohol (C3H8O), Acetone (C3H6O), p-Xylene (C8H10), MEK (C4H8O) adn Styrene (C8H8).

GDS-IR-1-110-0
(436)

GDS  GDS-IR-1-110-0

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Combustibles LEL (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Methane (CH4), Propane (C3H8), Isobutane (C4H10), Pentane (C5H12), Cyclopentane (C5H10), n-Butane (C4H10), Ethanol (C2H6O), Methanol (CH4O), Hexane (C6H14), Jet-A, Diesel and Gasoline.

XNXUTAVNNIF1
(1225)

HONEYWELL  XNXUTAVNNIF1

Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20 mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional Alarm Relays, Modbus, Fieldbus. *** Detector will be provided as two separate items: XNX transmitter & MPD sensor head, to be assembled by the end user ***

Configure

$2,276.97 
XNXUTAVNNIV1
(2141)

HONEYWELL  XNXUTAVNNIV1

Honeywell XNX Universal Gas Detector Transmitter including MPD-AM1V1 IR Infrared sensor combustible 0-5% Vol 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART over 4-20 mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional Alarm Relays, Modbus, Fieldbus. *** Detector will be provided as two separate items: XNX transmitter & MPD sensor head, to be assembled by the end user ***

Configure

$2,380.43 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.